Designed for measurements of AC currents up to 1000 A with a 1000:1 step-down ratio, this probe offers an accuracy of 0.3% error at full range and small phase shift at 0.7° at full range. Thanks to the high-permeability Ni-Fe alloy, this probe is reliable and achieves high performance every time.
Designed for measurements of AC currents up to 1000 A with a 1000:1 step-down ratio, this probe offers an accuracy of 0.3% error at full range and small phase shift at 0.7° at full range. Thanks to the high-permeability Ni-Fe alloy, this probe is reliable and achieves high performance every time.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Current Clamps category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
| Electrical Specifications | |
| Step-Down Current Ratio | 1000:1 |
| Sensitivity | 1 mA/A |
| Maximum Continuous Current | 1000 A at ≤500 Hz 100 A at >500 Hz |
| Frequency Bandwidth | 15 Hz to 10 kHz |
| Crest Factor | ≥6 for current up to 2000 A peak (300 A RMS) |
| Influence of Crest Factor | ≤1% for CF≤4 |
| Nominal Load Impedance | ≤1 Ω (burden resistance) |
| Maximum Output Voltage | ≤28 V peak (electronic limiter) |
| Influence of Frequency | 30 Hz to 5 kHz ≤0.25% |
| Influence of Conductor Position in the Jaws | ≤0.3% of amplitude |
| Load influence up to 5 Ω | Amplitude within specification up to 900 A ≤0.25% of amplitude above 900 A ≤0.1° on phase |
| Influence of DC Offset | ≤2% up to 20 A DC |
| Working Voltage | ≤600 V RMS |
| Environmental Specifications | |
| Temperature | Operating:-4 to 122°F, <85% RH (-20 to 50°C, <85% RH)<br> (excluding ice or dirt in the jaws) Storage: 40to 158°F, <85% RH |
| Influence | Temperature: ≤0.1% on amplitude phase within specification Humidity: amplitude and phase within specification (excludes ice or dirt on the jaws) |
| Maximum Conductor Diameter | 2" (52 mm) |
| General Specifications | |
| Operating Altitude | 6561' (2000 m) |
| Output Terminals | 0.15" (4 mm) shrouded sockets |
| Electrical Safety | EC 61010-1:2010 + IEC 61010-2-IEC61010-2-032:2002 |
| EMC | IEC61326-1 |
| Casing Protection | IP40 with jaws closed |
| Safety | CAT IV 600 V Pollution degree 2 |
| Dimensions | 1.77 x 4.33 x 8.5"(45 x 110 x 218 mm) |
| Weight | 1.5 lbs (700 g) |
Click on a category to view a selection of compatible accessories with the Megger ICLAMP Current Probe, 1000 A AC.
| Electrical Specifications | |
| Step-Down Current Ratio | 1000:1 |
| Sensitivity | 1 mA/A |
| Maximum Continuous Current | 1000 A at ≤500 Hz 100 A at >500 Hz |
| Frequency Bandwidth | 15 Hz to 10 kHz |
| Crest Factor | ≥6 for current up to 2000 A peak (300 A RMS) |
| Influence of Crest Factor | ≤1% for CF≤4 |
| Nominal Load Impedance | ≤1 Ω (burden resistance) |
| Maximum Output Voltage | ≤28 V peak (electronic limiter) |
| Influence of Frequency | 30 Hz to 5 kHz ≤0.25% |
| Influence of Conductor Position in the Jaws | ≤0.3% of amplitude |
| Load influence up to 5 Ω | Amplitude within specification up to 900 A ≤0.25% of amplitude above 900 A ≤0.1° on phase |
| Influence of DC Offset | ≤2% up to 20 A DC |
| Working Voltage | ≤600 V RMS |
| Environmental Specifications | |
| Temperature | Operating:-4 to 122°F, <85% RH (-20 to 50°C, <85% RH)<br> (excluding ice or dirt in the jaws) Storage: 40to 158°F, <85% RH |
| Influence | Temperature: ≤0.1% on amplitude phase within specification Humidity: amplitude and phase within specification (excludes ice or dirt on the jaws) |
| Maximum Conductor Diameter | 2" (52 mm) |
| General Specifications | |
| Operating Altitude | 6561' (2000 m) |
| Output Terminals | 0.15" (4 mm) shrouded sockets |
| Electrical Safety | EC 61010-1:2010 + IEC 61010-2-IEC61010-2-032:2002 |
| EMC | IEC61326-1 |
| Casing Protection | IP40 with jaws closed |
| Safety | CAT IV 600 V Pollution degree 2 |
| Dimensions | 1.77 x 4.33 x 8.5"(45 x 110 x 218 mm) |
| Weight | 1.5 lbs (700 g) |
Click on a category to view a selection of compatible accessories with the Megger ICLAMP Current Probe, 1000 A AC.