Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A

Model: BD-59092

Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A

Model: BD-59092

The lightweight, handheld unit made to deliver up to 240 Amps. Performs measurement of resistance of circuit breaker contacts, bus-bar joints, and other high-current links. This product is designed with safety, ease of use and versatility in mind.

The lightweight, handheld unit made to deliver up to 240 Amps. Performs measurement of resistance of circuit breaker contacts, bus-bar joints, and other high-current links. This product is designed with safety, ease of use and versatility in mind.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Ohmmeters category for similar products.

Or let's do a search and help you find what you need:


Megger BD-59092 Offers

Features

  • Up to 240 A
  • Bluetooth® headset for audible pass/fail testing against adjustable limits
  • Battery powered
  • Handheld, lightweight, weighing only 2.2 lbs (1 kg)
  • Safe test - DualGround™
  • Auto range from 1 microohm to 1000 milliohms
  • Ultra capacitor technology (patent pending)

Applications

  • Circuit breaking testing
  • Testing of bus-bar
  • Switches
  • Disconnecting devices
  • Safety ground connections
  • Welding points
  • Fuses
  • Cables

Both Sides Grounded

Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.

Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.

Instrument Front View

  • 1. Current output terminal (-)
  • 2. Current output terminal (+)
  • 3. Display
  • 4. Ground (earth) terminal
  • 5. Keys for navigation and to make settings in the display
  • 6. TEST-button
  • 7. Stand-by/Wake up (Press shortly to toggle)
  • 8. Clear log (Press and hold for 5 seconds)
  • 9. Function selector
  • 10. Connector for the voltage (–) sense lead
  • 11. Connector for the voltage sense (+) lead and the trig function
  • 12. Connector for the battery charger
  • 13. Battery charger indicator


The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.

The Kelvin clamps (included in BD-59092) use the same principle.

Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.∏∏

Megger BD-59092 Specifications

Application Field For use in high-voltage substations and industrial environments.
Recharge Time < 12 h
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Battery Charger Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life  
Audible Feedback Different buzzer sounds
User Presets 3
Field Calibration Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only
Click here for complete specifications on the Megger BD-59092

What's included with the Megger BD-59092

  • MOM2 Micro-Ohmmeter
  • 4 ft. (1.3 m) Test Cables with Kelvin Probes (including one with trig button) (2)
  • Transport Case
  • Charger
  • Rubber Holster
  • Carrying Strap
  • Belt Clip
  • MOM2 Win Software

Click on a category to view a selection of compatible accessories with the Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A.

Megger GA-00373 Test Cable with Kelvin clamp for the MOM2, 4', red, 16 mm² GA-00373
Heavy-duty 4' (1.3 m) Kelvin clamp test cable for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.




Megger GA-00371 Test Cable with Kelvin clamp for the MOM2, 4', black, 16 mm² GA-00371
Heavy-duty 4' (1.3 m) Kelvin clamp test cable for the MOM2, featuring a 16 mm² black lead for accurate low-resistance measurements.




Megger GA-00370 Test Cable with Kelvin clamp with trigger button for the MOM2, 4', red, 16 mm² GA-00370
Heavy-duty 4' (1.3 m) Kelvin clamp test cable with trigger button for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.




Megger GA-00376 Test Cable with Kelvin clamp for the MOM2, 33', black, 16 mm² GA-00376
Heavy-duty 33' (10 m) Kelvin clamp test cable with trigger button for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.This length in combination with the cable area 16 mm² results in a reduction of maximum current.




Ask a question about Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A

Customer Reviews for the Megger BD-59092

Megger BD-59092 Offers

Features

  • Up to 240 A
  • Bluetooth® headset for audible pass/fail testing against adjustable limits
  • Battery powered
  • Handheld, lightweight, weighing only 2.2 lbs (1 kg)
  • Safe test - DualGround™
  • Auto range from 1 microohm to 1000 milliohms
  • Ultra capacitor technology (patent pending)

Applications

  • Circuit breaking testing
  • Testing of bus-bar
  • Switches
  • Disconnecting devices
  • Safety ground connections
  • Welding points
  • Fuses
  • Cables

Both Sides Grounded

Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.

Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.

Instrument Front View

  • 1. Current output terminal (-)
  • 2. Current output terminal (+)
  • 3. Display
  • 4. Ground (earth) terminal
  • 5. Keys for navigation and to make settings in the display
  • 6. TEST-button
  • 7. Stand-by/Wake up (Press shortly to toggle)
  • 8. Clear log (Press and hold for 5 seconds)
  • 9. Function selector
  • 10. Connector for the voltage (–) sense lead
  • 11. Connector for the voltage sense (+) lead and the trig function
  • 12. Connector for the battery charger
  • 13. Battery charger indicator


The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.

The Kelvin clamps (included in BD-59092) use the same principle.

Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.∏∏

Megger BD-59092 Specifications

Application Field For use in high-voltage substations and industrial environments.
Recharge Time < 12 h
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Battery Charger Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life  
Audible Feedback Different buzzer sounds
User Presets 3
Field Calibration Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only
Click here for complete specifications on the Megger BD-59092

What's included with the Megger BD-59092

  • MOM2 Micro-Ohmmeter
  • 4 ft. (1.3 m) Test Cables with Kelvin Probes (including one with trig button) (2)
  • Transport Case
  • Charger
  • Rubber Holster
  • Carrying Strap
  • Belt Clip
  • MOM2 Win Software

Click on a category to view a selection of compatible accessories with the Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A.

Megger GA-00373 Test Cable with Kelvin clamp for the MOM2, 4', red, 16 mm² GA-00373
Heavy-duty 4' (1.3 m) Kelvin clamp test cable for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.




Megger GA-00371 Test Cable with Kelvin clamp for the MOM2, 4', black, 16 mm² GA-00371
Heavy-duty 4' (1.3 m) Kelvin clamp test cable for the MOM2, featuring a 16 mm² black lead for accurate low-resistance measurements.




Megger GA-00370 Test Cable with Kelvin clamp with trigger button for the MOM2, 4', red, 16 mm² GA-00370
Heavy-duty 4' (1.3 m) Kelvin clamp test cable with trigger button for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.




Megger GA-00376 Test Cable with Kelvin clamp for the MOM2, 33', black, 16 mm² GA-00376
Heavy-duty 33' (10 m) Kelvin clamp test cable with trigger button for the MOM2, featuring a 16 mm² red lead for accurate low-resistance measurements.This length in combination with the cable area 16 mm² results in a reduction of maximum current.




Ask a question about Megger BD-59092 MOM2, Micro-Ohmmeter, Kelvin Clamps, 240A

Customer Reviews for the Megger BD-59092

More Megger Products

How to Effectively Protect and Maintain Wind Turbines