The AVO215 True RMS Digital Multimeter offers a wide range of functions in a pocket-sized, yet rugged package. It meets CAT III 600 V AC/DC safety standards and features a built-in flashlight, making it ideal for wide range of applications.
The AVO215 True RMS Digital Multimeter offers a wide range of functions in a pocket-sized, yet rugged package. It meets CAT III 600 V AC/DC safety standards and features a built-in flashlight, making it ideal for wide range of applications.
The AVO215 includes such user-friendly features as auto and manual ranging, data hold, MAX/MIN recording, and a built-in flashlight, enhancing usability in diverse working conditions. It meets CAT III 600 V AC/DC safety standards and is designed to withstand drops up to 2 meters, ensuring reliability in harsh environments.
Features
Applications
DC Voltage | |
400 mV | Resolution: 0.1 mV Accuracy: ±(1.0% reading + 5 digits) |
4 V | Resolution: 0.001 V Accuracy: ±(1.0% reading + 3 digits) |
40 V | Resolution: 0.01 V Accuracy: ±(1.0% reading + 3 digits) |
400 V | Resolution: 0.1 V Accuracy: ±(1.0% reading + 3 digits) |
600 V | Resolution: 1 V Accuracy: ±(1.0% reading + 3 digits) |
AC Voltage | |
4 V | Resolution: 0.001 V Accuracy: ±(1.2% reading + 5 digits) |
40 V | Resolution: 0.01 V Accuracy: ±(1.2% reading + 5 digits) |
400 V | Resolution: 0.1 V Accuracy: ±(1.2% reading + 5 digits) |
600 V | Resolution: 1 V Accuracy: ±(1.2% reading + 5 digits) |
Note | All AC voltage ranges are specified from 5 of range to 100% of range |
DC Current | |
400 µA | Resolution: 0.1 µA Accuracy: ±(1.0% reading + 3 digits) |
4000 µA | Resolution: 1 µA Accuracy: ±(1.0% reading + 3 digits) |
40 mA | Resolution: 0.01 mA Accuracy: ±(1.2% reading + 3 digits) |
400 mA | Resolution: 0.1 mA Accuracy: ±(1.2% reading + 3 digits) |
4 A | Resolution: 0.001 A Accuracy: ±(1.2% reading + 3 digits) |
10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) (20 A: 30 seconds maximum with reduced accuracy) |
Note | (20 A: 30 seconds maximum with reduced accuracy) |
AC Current | |
400 µA | Resolution: 0.1 µA Accuracy: ±(1.2% reading + 3 digits) |
4000 µA | Resolution: 1 µA Accuracy: ±(1.2% reading + 3 digits) |
40 mA | Resolution: 0.01 mA Accuracy: ±(1.5% reading + 5 digits) |
400 mA | Resolution: 0.1 mA Accuracy: ±(1.5% reading + 5 digits) |
4 A | Resolution: 0.001 A Accuracy: ±(1.8% reading + 5 digits) |
10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) |
Note | (20 A: 30 seconds maximum with reduced accuracy) |
Resistance | |
400 Ω | Resolution: 0.1 Ω Accuracy: ±(1.5% reading + 5 digits) |
4 kΩ | Resolution: 0.001 kΩ Accuracy: ±(1.5% reading + 5 digits) |
40 kΩ | Resolution: 0.01 kΩ Accuracy: ±(1.5% reading + 5 digits) |
400 kΩ | Resolution: 0.1 kΩ Accuracy: ±(1.5% reading + 5 digits) |
4 MΩ | Resolution: 0.001 MΩ Accuracy: ±(2.5% reading + 20 digits) |
40 MΩ | Resolution: 0.01 MΩ Accuracy: ±(2.5% reading + 20 digits) |
Capacitance | |
40 nF | Resolution: 0.01 nF Accuracy: ±(4.5% reading + 10 digits) |
400 nF | Resolution: 0.1 nF Accuracy: ±(3.0% reading + 5 digits) |
4 µF | Resolution: 0.001 µF Accuracy: ±(3.0% reading + 5 digits) |
40 µF | Resolution: 0.01 µF Accuracy: ±(5% reading + 5 digits) |
400 µF | Resolution: 0.1 µF Accuracy: ±(5% reading + 5 digits) |
4000 µF | Resolution: 1 µF Accuracy: ±(5% reading + 5 digits) |
Frequency | |
10 Hz to 10 kHz | Resolution: 0.01 Hz Accuracy: ±(1.2% reading) Sensitivity: 15 V rms |
Duty Cycle | |
0.1 to 99.9% | Resolution: 0.1 % Accuracy: ±(1.2% reading + 2 digits) Note: Pulse width: 100 µs to 100 ms Frequency: 5 Hz to 150 kHz |
General Specifications | |
Diode Test | Test current of 1.5 mA max, open circuit voltage 3 V DC typical |
Continuity Check | Audible signal if resistance <50 Ω (approx.), test current <0.35 mA |
Input Impedance | >10 MΩ (V DC / V AC) |
AC Response | True RMS |
ACV Bandwidth | 50/60 Hz (all waveforms) 45 to 1000 Hz (sine wave) |
Crest Factor | ≤3 at full scale up to 300 V, decreasing linearly to ≤1.5 at 600 V |
Display | 4000 counts / positive display |
Overrange Indication | OL' is displayed |
Polarity | Automatic, minus symbol for negative values |
Measurement Rate | 3 times per second |
Fuses | mA / µA ranges: 0.5 A 600 V ceramic quick blow A range: 10 A 600 V ceramic quick blow |
Environmental Conditions | Operating temperature: 41 to 104 °F (5 to 40 °C) Storage temperature: -4 to 140 °F (-20 to 60 °C) Operating humidity: Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40 °C) Storage humidity: <80% Operating altitude: ≤7000' (2000 m) Drop test: 6.5' (2 m) |
Safety Rating | IEC61010, CAT III 600 V |
Battery | 2 x 1.5 V AAA |
Dimensions | 182 x 82 x 59 mm |
Weight | 0.753 lbs (342 g) |
DC Voltage | |
400 mV | Resolution: 0.1 mV Accuracy: ±(1.0% reading + 5 digits) |
4 V | Resolution: 0.001 V Accuracy: ±(1.0% reading + 3 digits) |
40 V | Resolution: 0.01 V Accuracy: ±(1.0% reading + 3 digits) |
400 V | Resolution: 0.1 V Accuracy: ±(1.0% reading + 3 digits) |
600 V | Resolution: 1 V Accuracy: ±(1.0% reading + 3 digits) |
AC Voltage | |
4 V | Resolution: 0.001 V Accuracy: ±(1.2% reading + 5 digits) |
40 V | Resolution: 0.01 V Accuracy: ±(1.2% reading + 5 digits) |
400 V | Resolution: 0.1 V Accuracy: ±(1.2% reading + 5 digits) |
600 V | Resolution: 1 V Accuracy: ±(1.2% reading + 5 digits) |
Note | All AC voltage ranges are specified from 5 of range to 100% of range |
DC Current | |
400 µA | Resolution: 0.1 µA Accuracy: ±(1.0% reading + 3 digits) |
4000 µA | Resolution: 1 µA Accuracy: ±(1.0% reading + 3 digits) |
40 mA | Resolution: 0.01 mA Accuracy: ±(1.2% reading + 3 digits) |
400 mA | Resolution: 0.1 mA Accuracy: ±(1.2% reading + 3 digits) |
4 A | Resolution: 0.001 A Accuracy: ±(1.2% reading + 3 digits) |
10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) (20 A: 30 seconds maximum with reduced accuracy) |
Note | (20 A: 30 seconds maximum with reduced accuracy) |
AC Current | |
400 µA | Resolution: 0.1 µA Accuracy: ±(1.2% reading + 3 digits) |
4000 µA | Resolution: 1 µA Accuracy: ±(1.2% reading + 3 digits) |
40 mA | Resolution: 0.01 mA Accuracy: ±(1.5% reading + 5 digits) |
400 mA | Resolution: 0.1 mA Accuracy: ±(1.5% reading + 5 digits) |
4 A | Resolution: 0.001 A Accuracy: ±(1.8% reading + 5 digits) |
10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) |
Note | (20 A: 30 seconds maximum with reduced accuracy) |
Resistance | |
400 Ω | Resolution: 0.1 Ω Accuracy: ±(1.5% reading + 5 digits) |
4 kΩ | Resolution: 0.001 kΩ Accuracy: ±(1.5% reading + 5 digits) |
40 kΩ | Resolution: 0.01 kΩ Accuracy: ±(1.5% reading + 5 digits) |
400 kΩ | Resolution: 0.1 kΩ Accuracy: ±(1.5% reading + 5 digits) |
4 MΩ | Resolution: 0.001 MΩ Accuracy: ±(2.5% reading + 20 digits) |
40 MΩ | Resolution: 0.01 MΩ Accuracy: ±(2.5% reading + 20 digits) |
Capacitance | |
40 nF | Resolution: 0.01 nF Accuracy: ±(4.5% reading + 10 digits) |
400 nF | Resolution: 0.1 nF Accuracy: ±(3.0% reading + 5 digits) |
4 µF | Resolution: 0.001 µF Accuracy: ±(3.0% reading + 5 digits) |
40 µF | Resolution: 0.01 µF Accuracy: ±(5% reading + 5 digits) |
400 µF | Resolution: 0.1 µF Accuracy: ±(5% reading + 5 digits) |
4000 µF | Resolution: 1 µF Accuracy: ±(5% reading + 5 digits) |
Frequency | |
10 Hz to 10 kHz | Resolution: 0.01 Hz Accuracy: ±(1.2% reading) Sensitivity: 15 V rms |
Duty Cycle | |
0.1 to 99.9% | Resolution: 0.1 % Accuracy: ±(1.2% reading + 2 digits) Note: Pulse width: 100 µs to 100 ms Frequency: 5 Hz to 150 kHz |
General Specifications | |
Diode Test | Test current of 1.5 mA max, open circuit voltage 3 V DC typical |
Continuity Check | Audible signal if resistance <50 Ω (approx.), test current <0.35 mA |
Input Impedance | >10 MΩ (V DC / V AC) |
AC Response | True RMS |
ACV Bandwidth | 50/60 Hz (all waveforms) 45 to 1000 Hz (sine wave) |
Crest Factor | ≤3 at full scale up to 300 V, decreasing linearly to ≤1.5 at 600 V |
Display | 4000 counts / positive display |
Overrange Indication | OL' is displayed |
Polarity | Automatic, minus symbol for negative values |
Measurement Rate | 3 times per second |
Fuses | mA / µA ranges: 0.5 A 600 V ceramic quick blow A range: 10 A 600 V ceramic quick blow |
Environmental Conditions | Operating temperature: 41 to 104 °F (5 to 40 °C) Storage temperature: -4 to 140 °F (-20 to 60 °C) Operating humidity: Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40 °C) Storage humidity: <80% Operating altitude: ≤7000' (2000 m) Drop test: 6.5' (2 m) |
Safety Rating | IEC61010, CAT III 600 V |
Battery | 2 x 1.5 V AAA |
Dimensions | 182 x 82 x 59 mm |
Weight | 0.753 lbs (342 g) |