The Legend Series™ HFC Refrigerant Analyzer offers rapid and accurate purity testing for HFC refrigerants in under 2 minutes. With a simple clean-air calibration, it measures both vapor and liquid samples, detects air and harmful refrigerant contaminants, and ensures precise purity verification across various applications.
The Legend Series™ HFC Refrigerant Analyzer offers rapid and accurate purity testing for HFC refrigerants in under 2 minutes. With a simple clean-air calibration, it measures both vapor and liquid samples, detects air and harmful refrigerant contaminants, and ensures precise purity verification across various applications.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
Confirming a refrigerant is the right gas before service or use will ensure all systems effectively operate while protecting the customer and the technician. The use of a refrigerant analyzer creates a cleaner recovery process and reduces the amount of mixed gas recovered. Reducing mix gas recovery will ultimately cut down on the amount of refrigerant that must be destroyed which helps improve the industries ecological footprint. A refrigerant analyzer is a valuable tool to safeguard users and equipment, while promoting recycling and reuse to protect the environment. The Legend HFC is the most advanced refrigerant analyzer in the market and provides the latest in NDIR technology to support refrigerant testing before use. Reduce the uncertainty and analyze every refrigerant before handling so you can ensure you are safeguarding yourself, your equipment, and the environment to certify the job is done right.
Features
Analyzed Refrigerants | R22, R32, R134a, R404A, R407C, R410A, Hydrocarbons (HC) and Air |
Identified Refrigerants | R12, R1234yf, R408A, R409A, R417A, R421A, R421B, R422A, R422B, R422C, R427A, Hydrocarbons |
Accuracy | ±1% of indicated gasses or better |
Power Requirements | 12 VDC @ 2A via 110/220 VAC, 50 – 60 Hz Adapter |
Approvals | CE, UL and CUL |
User Interface | Graphic Display, Soft Keys, Built in Printer |
Sample Gas Extraction | Pressure from cylinder or system |
Temperature Range | 50 to 120°F (10 to 49°C) |
Humidity | 0 to 95% RH non-condensing |
Test Sample Size | 0.18 oz (5 g) per test |
Test Pressure | 30 psig to 500 psig |
Weight | Less than 10 lbs (4.5 kg) |
Analyzed Refrigerants | R22, R32, R134a, R404A, R407C, R410A, Hydrocarbons (HC) and Air |
Identified Refrigerants | R12, R1234yf, R408A, R409A, R417A, R421A, R421B, R422A, R422B, R422C, R427A, Hydrocarbons |
Accuracy | ±1% of indicated gasses or better |
Power Requirements | 12 VDC @ 2A via 110/220 VAC, 50 – 60 Hz Adapter |
Approvals | CE, UL and CUL |
User Interface | Graphic Display, Soft Keys, Built in Printer |
Sample Gas Extraction | Pressure from cylinder or system |
Temperature Range | 50 to 120°F (10 to 49°C) |
Humidity | 0 to 95% RH non-condensing |
Test Sample Size | 0.18 oz (5 g) per test |
Test Pressure | 30 psig to 500 psig |
Weight | Less than 10 lbs (4.5 kg) |