MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Model: PRTrans1000-300-PSIG

MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Model: PRTrans1000-300-PSIG

Rugged and submersible, this transient pressure data logger records time and date stamped transient pressure event data at user-defined intervals and threshold trigger over a range of 0 to 300 psig.

Please note: The Madgetech IFC200 USB Interface Cable Package is a required accessory for use with this product.

Rugged and submersible, this transient pressure data logger records time and date stamped transient pressure event data at user-defined intervals and threshold trigger over a range of 0 to 300 psig.

Please note: The Madgetech IFC200 USB Interface Cable Package is a required accessory for use with this product.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

MadgeTech PR1000-300-PSIG Pressure and Temperature Data Logger, 0 to 300 psig-

MadgeTech PR1000-300-PSIG Pressure and Temperature Data Logger, 0 to 300 psig

Model: PR1000-300-PSIG | Order No: 902248-00

Features a ¼ " NPT fitting, the data logger with 0 to 300 psig range can take temperature, pressure, and transient pressure measurements. It is fully submersible and stands at 4" tall and 1" in diameter. It can store more than 1.3 million readings with an internal temperature sensor that provides measurements from -40 to 176°F (-40 to 80°C) with an accuracy of ±2.0°C.


MadgeTech PRTrans1000-300-PSIG Offers

Features

  • 100 Hz operation
  • Software selectable trigger modes and threshold levels
  • Rugged
  • Reusable
  • Submersible
  • Programmable start time
  • 32 sample pre-trigger buffer
  • 1/4" NPT pressure port

Applications

  • Water hammer
  • Compressors
  • Pumps
  • Pneumatics/hydraulics
  • Process control systems
  • Lubrication systems
  • Chemical processing
  • Pressure reducing valves
  • Waste water treatment
  • HVAC/R

MadgeTech PRTrans1000-300-PSIG Specifications

Pressure Sensor: Semiconductor strain gauge
Range: 0 to 300 PSIA/G; 1000 PSIA
Resolution: 0.02, 0.1, 0.2, 0.5 PSIA/G; 1.0, 5.0 PSIA
Response Time: 0.1 ms (10 to 90% FSR)
Calibrated Accuracy 2% FSR, 0.25% at 77°F (25°C) typical
Repeatability ±0.5% FSR; ±0.2% typical
Adaptor 1/4" male NPT or fully submersible
Trigger Modes Software programmable window size or bi-level start/stop triggers
Start Modes Software programmable for immediate start
Real Time Recording May be used with PC to monitor and record data in real time
Memory 262,143 samples
Number of Events Up to 255 triggered events
Pre-Trigger Size Up to 32 samples
Reading Interval 1 reading every 10 ms up to 1 reading every second
Calibration Digital calibration through software
Date: Automatically recorded within device
Battery Type: 3.6 V lithium battery included; user replaceable
Life: 3 days continuous at 10 ms sample rate
Shelf Life Up to 1 year when device is not in use
Data Format Date and time stamped PSIA(G), inches, feet, mmHg, bar, Torr, kPa
Computer Interface USB (interface cable required); 115,200 baud
Software XP SP3/Vista/Windows 7/Windows 8
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 100% RH
Materials Stainless Steel
Approvals CE
Dimensions 6.4 x 1.25" (163 x 32 mm)
Weight 12 oz (340 g)
Click here for complete specifications on the MadgeTech PRTrans1000-300-PSIG

What's included with the MadgeTech PRTrans1000-300-PSIG

  • MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Click on a category to view a selection of compatible accessories with the MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig.

MadgeTech SVP-Secure Secure Validation Software SVP-Secure System
IQ/OQ/PQ Secure Software Validation Workbook and Software Package.




MadgeTech TLH-5902 Lithium Battery, 3.6V TLH-5902
1/2 AA, axial leads, rated up to 125°C.




MadgeTech PRTrans1000-O-Ring Replacement O-Rings, Set of 2 PRTrans1000-O-Ring
One set of replacement O-rings for PRTrans1000 Series data loggers (not available for intrinsically safe products).




MadgeTech IFC200 USB Interface Cable Package IFC200
“Plug and play” interface communicates between stand alone data loggers and MadgeTech software. Through this interface, loggers can be started, stopped or downloaded.




Ask a question about MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Customer Reviews for the MadgeTech PRTrans1000-300-PSIG

MadgeTech PRTrans1000-300-PSIG Offers

Features

  • 100 Hz operation
  • Software selectable trigger modes and threshold levels
  • Rugged
  • Reusable
  • Submersible
  • Programmable start time
  • 32 sample pre-trigger buffer
  • 1/4" NPT pressure port

Applications

  • Water hammer
  • Compressors
  • Pumps
  • Pneumatics/hydraulics
  • Process control systems
  • Lubrication systems
  • Chemical processing
  • Pressure reducing valves
  • Waste water treatment
  • HVAC/R

MadgeTech PRTrans1000-300-PSIG Specifications

Pressure Sensor: Semiconductor strain gauge
Range: 0 to 300 PSIA/G; 1000 PSIA
Resolution: 0.02, 0.1, 0.2, 0.5 PSIA/G; 1.0, 5.0 PSIA
Response Time: 0.1 ms (10 to 90% FSR)
Calibrated Accuracy 2% FSR, 0.25% at 77°F (25°C) typical
Repeatability ±0.5% FSR; ±0.2% typical
Adaptor 1/4" male NPT or fully submersible
Trigger Modes Software programmable window size or bi-level start/stop triggers
Start Modes Software programmable for immediate start
Real Time Recording May be used with PC to monitor and record data in real time
Memory 262,143 samples
Number of Events Up to 255 triggered events
Pre-Trigger Size Up to 32 samples
Reading Interval 1 reading every 10 ms up to 1 reading every second
Calibration Digital calibration through software
Date: Automatically recorded within device
Battery Type: 3.6 V lithium battery included; user replaceable
Life: 3 days continuous at 10 ms sample rate
Shelf Life Up to 1 year when device is not in use
Data Format Date and time stamped PSIA(G), inches, feet, mmHg, bar, Torr, kPa
Computer Interface USB (interface cable required); 115,200 baud
Software XP SP3/Vista/Windows 7/Windows 8
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 100% RH
Materials Stainless Steel
Approvals CE
Dimensions 6.4 x 1.25" (163 x 32 mm)
Weight 12 oz (340 g)
Click here for complete specifications on the MadgeTech PRTrans1000-300-PSIG

What's included with the MadgeTech PRTrans1000-300-PSIG

  • MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Click on a category to view a selection of compatible accessories with the MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig.

MadgeTech SVP-Secure Secure Validation Software SVP-Secure System
IQ/OQ/PQ Secure Software Validation Workbook and Software Package.




MadgeTech TLH-5902 Lithium Battery, 3.6V TLH-5902
1/2 AA, axial leads, rated up to 125°C.




MadgeTech PRTrans1000-O-Ring Replacement O-Rings, Set of 2 PRTrans1000-O-Ring
One set of replacement O-rings for PRTrans1000 Series data loggers (not available for intrinsically safe products).




MadgeTech IFC200 USB Interface Cable Package IFC200
“Plug and play” interface communicates between stand alone data loggers and MadgeTech software. Through this interface, loggers can be started, stopped or downloaded.




Ask a question about MadgeTech PRTrans1000-300-PSIG Transient Pressure Data Logger, 0 to 300 psig

Customer Reviews for the MadgeTech PRTrans1000-300-PSIG

More MadgeTech Products