08
days
22
hours
24
mins

Independence Day Promotion - Be the first to know the details of this promo
Independence Day Promotion - Be the first to know the details of this promo

MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

Differential pressure and temperature data logger accepts thermocouple types J, K, T, E, R, S, B, and N. Features a 10,922-measurement per channel storage capacity and 5-year battery life.

Differential pressure and temperature data logger accepts thermocouple types J, K, T, E, R, S, B, and N. Features a 10,922-measurement per channel storage capacity and 5-year battery life.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Internal Sensor Data Loggers category for similar products.

Or let's do a search and help you find what you need:


MadgeTech PRTC110 Specifications

Remote Channel Temperature Sensor Thermocouple Types J, K, T, E, R, S, B, or N
Remote Channel Temperature Range Thermocouple Dependent
Remote Channel Temperature Resolution Thermocouple Dependent
Remote Channel Temperature Calibrated Accuracy Thermocouple Dependent
Pressure SensorSemiconductor
Pressure Range0 to 2 inH2O or 0 to 5 inH2O (differential)
Pressure Resolution0.002 inH2O and 0.005 inH2O
Pressure Calibrated Accuracy0.5 %FSR, 0.25 % at 25 °C typical
Memory10,922 readings per channel
Reading Rate1 reading every 2 seconds to 1 reading every 24 hours
Baud Rate57,600
Cold Junction CompensationAutomatic
LED IndicatorsRed
MaterialABS Plastic
Dimensions2.7 in x 1.6 in x 0.8 in (68 mm x 41 mm x 20 mm) plus connective tubing
Operating Environment-20 °C to +80 °C, 0 %RH to 95 %RH non-condensing
ApprovalsCE
ThermocoupleRange (°C)ResolutionAccuracy
J-210 to +7600.1 °C±.5 °C
K-270 to +13700.1 °C±.5 °C
T-270 to +4000.1 °C±.5 °C
E-270 to +9800.1 °C±.5 °C
R-50 to +17600.5 °C±2 °C
S-50 to +17600.5 °C±2 °C
B+50 to +18200.5 °C±2 °C
N-270 to +13000.1 °C±.5 °C
Click here for complete specifications on the MadgeTech PRTC110

What's included with the MadgeTech PRTC110

  • MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

Ask a question about MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

Customer Reviews for the MadgeTech PRTC110

MadgeTech PRTC110 Specifications

Remote Channel Temperature Sensor Thermocouple Types J, K, T, E, R, S, B, or N
Remote Channel Temperature Range Thermocouple Dependent
Remote Channel Temperature Resolution Thermocouple Dependent
Remote Channel Temperature Calibrated Accuracy Thermocouple Dependent
Pressure SensorSemiconductor
Pressure Range0 to 2 inH2O or 0 to 5 inH2O (differential)
Pressure Resolution0.002 inH2O and 0.005 inH2O
Pressure Calibrated Accuracy0.5 %FSR, 0.25 % at 25 °C typical
Memory10,922 readings per channel
Reading Rate1 reading every 2 seconds to 1 reading every 24 hours
Baud Rate57,600
Cold Junction CompensationAutomatic
LED IndicatorsRed
MaterialABS Plastic
Dimensions2.7 in x 1.6 in x 0.8 in (68 mm x 41 mm x 20 mm) plus connective tubing
Operating Environment-20 °C to +80 °C, 0 %RH to 95 %RH non-condensing
ApprovalsCE
ThermocoupleRange (°C)ResolutionAccuracy
J-210 to +7600.1 °C±.5 °C
K-270 to +13700.1 °C±.5 °C
T-270 to +4000.1 °C±.5 °C
E-270 to +9800.1 °C±.5 °C
R-50 to +17600.5 °C±2 °C
S-50 to +17600.5 °C±2 °C
B+50 to +18200.5 °C±2 °C
N-270 to +13000.1 °C±.5 °C
Click here for complete specifications on the MadgeTech PRTC110

What's included with the MadgeTech PRTC110

  • MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

Ask a question about MadgeTech PRTC110 Differential Pressure/Temperature Data Logger

Customer Reviews for the MadgeTech PRTC110

More MadgeTech Products