MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Model: HiTemp140-TC | Order No: 902424-00

MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Model: HiTemp140-TC | Order No: 902424-00

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector, compatible with a wide range of thermocouple types. It can operate up to 284°F (140.0°C).

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector, compatible with a wide range of thermocouple types. It can operate up to 284°F (140.0°C).

Your Price $539.00 USD
Availability 2 to 3 Weeks
Quantity

MadgeTech HiTemp140-TC Offers

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector. Compatible with a wide variety of thermocouple probes, this data logger is capable of measuring temperature as high as 3308°F (1820°C) and as low as -454°F (-270°C) (probe dependent).

All of MadgeTech’s HiTemp140 data loggers are made of food grade stainless steel and can be placed in environments with temperatures as high as 284°F (140°C). The operating range of the data logger body can be extended to higher temperatures when used with MadgeTech’s thermal barrier options and suitable probe.

Using the MadgeTech 4 Software, starting, stopping and downloading the HiTemp140-TC is simple and easy. To use, simply place the HiTemp140-TC in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K, °R, or mV. The data can also be automatically exported to Excel® for further calculations.

Features

  • Measurement range of -454 to 3308°F (-270 to 1820°C)
  • ±0.9°F (±0.5°C) accuracy (probe dependent)
  • SMP thermocouple
  • User replaceable battery
  • Trigger options
  • Programmable start and stop time

Applications

  • Depyrogenation
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Pasteurization
  • Many more applications (probe dependent)

MadgeTech HiTemp140-TC Specifications

Internal
Temperature Range -40°F to 284°F (-40 to 140°C)
Temperature Resolution 0.02°F (0.01°C)
Calibrated Accuracy ±0.9°F from 32 to 122°F (±0.5°C from 0 to 50°C)
Thermocouple
Thermocouple Types J, K, T, E, R, S, B, N
Meaurement Range -454 to 3308°F (-270 to 1820°C) (Probe Dependent)
Connector Type Female subminiature (SMP)
Cold Junction Compensation Automatic, based on internal channel
Maximum Thermocouple Resistance 100 Ω
Thermocouple J
Range: -346 to 1400°F (-210 to 760°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

K
Range: -454 to 2498°F (-270 to 1370°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

T
Range: -454 to 752°F (-270 to 400°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

E
Range: -454 to 1796°F (-270 to 980°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

R
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

S
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

B
Range: 122 to 3308°F (50 to 1820°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

N
Range: -454 to 2372°F (-270 to 1300°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)
General Specifications
Start Modes Software programmable immediate start; Delay start up to 18 months in advance
Stop Modes Manual or Timed (specific date and time)
Real Time Recording May be used with PC to monitor and record data in real time
Password Protection Optional password may be programmed to restrict configuration access
Memory 16,256 readings
5,418 readings in trigger settings mode
Wrap Around Yes
Reading Rate 1 reading per second up to 1 reading every 24 hours
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Battery Type: 3.6V high-temperature lithium battery; user replaceable
Life: 2 years typical (1 minute reading rate at 77°F (25°C))
Data Format Date and time stamped °C, K, °F, °R, or mV
Time Accuracy ±1 minute/month at 77 °F (25°C)
Computer Interface IFC400 or IFC406 USB docking station required
125,000 baud
Operating System Compatibility Windows XP SP3 or later
Software Compatibility MadgeTech Standard Software version 4.2.25.15 or later
MadgeTech Secure Software version 4.2.24.16 or later
Operating Environment -40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH non-condensing, 0.002 PSIA to 100 PSIA
IP Rating IP50
Material 316 Stainless Steel, PPSU, Glass-Filled Thermoplastic
Approvals CE
Dimensions Body: 2.20 x 1.0 x 1.0" (55.9 x 26.4 x 26.4 mm)
Weight 3.49 oz (99 g)
Click here for complete specifications on the MadgeTech HiTemp140-TC

What's included with the MadgeTech HiTemp140-TC

  • MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Click on a category to view a selection of compatible accessories with the MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F.

MadgeTech HiTemp140-O-Ring Set of Replacement O-Rings for the HiTemp140 series HiTemp140-O-Ring
Compatible with the HiTemp140 data logger series, this set of replacement O-rings ensures a secure, waterproof seal for high-temperature environments. In addition, these rings are perfect for maintaining device integrity and performance.




MadgeTech Key Ring End Cap for the HiTemp140 series/PRTemp140/PR140/RHTemp1000 Key Ring End Cap
Compatible with the HiTemp140 series, PRTemp140, PR140, and RHTemp1000 data loggers, this key ring end cap is used in place of the standard bottom. In addition, this ring can easily attach to your key ring or lanyard.




MadgeTech MagMount-1 Magnetic Holder for the PR140/PRTemp140/HiTemp140 series/Temp1000/RHTemp1000 MagMount-1
Compatible with the PR140, PRTemp140, HiTemp140 series, Temp1000, and RHTemp1000 data loggers, this magnetic holder can be placed in environments from -112 to 176°F (-80 to 80°C), making it ideal for use in refrigerators, freezers, and incubators.




MadgeTech MultiMount-Z Versatile Mount for the HiTemp140 series MultiMount-Z
Compatible with the HiTemp140 data logger series, this versatile mount is ideal for stabilizing a logger inside an autoclave or screwed to a flat surface to create an anchored base. In addition, this mount can withstand temperatures up to 302°F (150°C), making it ideal for use in autoclave sterilization processes.




MadgeTech DLS100 Versatile Stand for the HiTemp140 series/PRTemp140/PR140/Temp1000/RHTemp1000 DLS100
Compatible with the HiTemp140 series, PRTemp140, PR140, Temp1000, and RHTemp1000 data loggers, this 316 stainless steel versatile stand is weighted to help stabilize data loggers while in use or used as a caddy when the logger is stored. In addition, this stand can withstand temperatures up to 302°F (150°C).




MadgeTech IFC400 Interface Cable Package IFC400
Interface Cable Package for HiTemp140 and PR140 Data Loggers. Includes MadgeTech software CD, software manual, Quick Start Guide, USB cable and USB docking station.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Ask a question about MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Customer Reviews for the MadgeTech HiTemp140-TC

MadgeTech HiTemp140-TC Offers

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector. Compatible with a wide variety of thermocouple probes, this data logger is capable of measuring temperature as high as 3308°F (1820°C) and as low as -454°F (-270°C) (probe dependent).

All of MadgeTech’s HiTemp140 data loggers are made of food grade stainless steel and can be placed in environments with temperatures as high as 284°F (140°C). The operating range of the data logger body can be extended to higher temperatures when used with MadgeTech’s thermal barrier options and suitable probe.

Using the MadgeTech 4 Software, starting, stopping and downloading the HiTemp140-TC is simple and easy. To use, simply place the HiTemp140-TC in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K, °R, or mV. The data can also be automatically exported to Excel® for further calculations.

Features

  • Measurement range of -454 to 3308°F (-270 to 1820°C)
  • ±0.9°F (±0.5°C) accuracy (probe dependent)
  • SMP thermocouple
  • User replaceable battery
  • Trigger options
  • Programmable start and stop time

Applications

  • Depyrogenation
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Pasteurization
  • Many more applications (probe dependent)

MadgeTech HiTemp140-TC Specifications

Internal
Temperature Range -40°F to 284°F (-40 to 140°C)
Temperature Resolution 0.02°F (0.01°C)
Calibrated Accuracy ±0.9°F from 32 to 122°F (±0.5°C from 0 to 50°C)
Thermocouple
Thermocouple Types J, K, T, E, R, S, B, N
Meaurement Range -454 to 3308°F (-270 to 1820°C) (Probe Dependent)
Connector Type Female subminiature (SMP)
Cold Junction Compensation Automatic, based on internal channel
Maximum Thermocouple Resistance 100 Ω
Thermocouple J
Range: -346 to 1400°F (-210 to 760°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

K
Range: -454 to 2498°F (-270 to 1370°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

T
Range: -454 to 752°F (-270 to 400°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

E
Range: -454 to 1796°F (-270 to 980°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

R
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

S
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

B
Range: 122 to 3308°F (50 to 1820°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

N
Range: -454 to 2372°F (-270 to 1300°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)
General Specifications
Start Modes Software programmable immediate start; Delay start up to 18 months in advance
Stop Modes Manual or Timed (specific date and time)
Real Time Recording May be used with PC to monitor and record data in real time
Password Protection Optional password may be programmed to restrict configuration access
Memory 16,256 readings
5,418 readings in trigger settings mode
Wrap Around Yes
Reading Rate 1 reading per second up to 1 reading every 24 hours
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Battery Type: 3.6V high-temperature lithium battery; user replaceable
Life: 2 years typical (1 minute reading rate at 77°F (25°C))
Data Format Date and time stamped °C, K, °F, °R, or mV
Time Accuracy ±1 minute/month at 77 °F (25°C)
Computer Interface IFC400 or IFC406 USB docking station required
125,000 baud
Operating System Compatibility Windows XP SP3 or later
Software Compatibility MadgeTech Standard Software version 4.2.25.15 or later
MadgeTech Secure Software version 4.2.24.16 or later
Operating Environment -40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH non-condensing, 0.002 PSIA to 100 PSIA
IP Rating IP50
Material 316 Stainless Steel, PPSU, Glass-Filled Thermoplastic
Approvals CE
Dimensions Body: 2.20 x 1.0 x 1.0" (55.9 x 26.4 x 26.4 mm)
Weight 3.49 oz (99 g)
Click here for complete specifications on the MadgeTech HiTemp140-TC

What's included with the MadgeTech HiTemp140-TC

  • MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Click on a category to view a selection of compatible accessories with the MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F.

MadgeTech HiTemp140-O-Ring Set of Replacement O-Rings for the HiTemp140 series HiTemp140-O-Ring
Compatible with the HiTemp140 data logger series, this set of replacement O-rings ensures a secure, waterproof seal for high-temperature environments. In addition, these rings are perfect for maintaining device integrity and performance.




MadgeTech Key Ring End Cap for the HiTemp140 series/PRTemp140/PR140/RHTemp1000 Key Ring End Cap
Compatible with the HiTemp140 series, PRTemp140, PR140, and RHTemp1000 data loggers, this key ring end cap is used in place of the standard bottom. In addition, this ring can easily attach to your key ring or lanyard.




MadgeTech MagMount-1 Magnetic Holder for the PR140/PRTemp140/HiTemp140 series/Temp1000/RHTemp1000 MagMount-1
Compatible with the PR140, PRTemp140, HiTemp140 series, Temp1000, and RHTemp1000 data loggers, this magnetic holder can be placed in environments from -112 to 176°F (-80 to 80°C), making it ideal for use in refrigerators, freezers, and incubators.




MadgeTech MultiMount-Z Versatile Mount for the HiTemp140 series MultiMount-Z
Compatible with the HiTemp140 data logger series, this versatile mount is ideal for stabilizing a logger inside an autoclave or screwed to a flat surface to create an anchored base. In addition, this mount can withstand temperatures up to 302°F (150°C), making it ideal for use in autoclave sterilization processes.




MadgeTech DLS100 Versatile Stand for the HiTemp140 series/PRTemp140/PR140/Temp1000/RHTemp1000 DLS100
Compatible with the HiTemp140 series, PRTemp140, PR140, Temp1000, and RHTemp1000 data loggers, this 316 stainless steel versatile stand is weighted to help stabilize data loggers while in use or used as a caddy when the logger is stored. In addition, this stand can withstand temperatures up to 302°F (150°C).




MadgeTech IFC400 Interface Cable Package IFC400
Interface Cable Package for HiTemp140 and PR140 Data Loggers. Includes MadgeTech software CD, software manual, Quick Start Guide, USB cable and USB docking station.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Ask a question about MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Customer Reviews for the MadgeTech HiTemp140-TC

More MadgeTech Products

Calibration Lab