03
days
01
hours
32
mins

March Momentum Promotion banner

03
days
01
hours
32
mins

March Momentum Promotion banner

MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Model: HiTemp140-1

MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Model: HiTemp140-1

A robust and highly accurate temperature data logger designed for use in harsh submersible environments and capable of withstanding temperatures up to 140°C (284°F). In addition, it can achieve an accuracy of ±0.1°C (0.18°F) over a wide temperature range and can store up to 65,536 readings. It features a rigid external probe capable of measuring extended temperature ranges up to 260°C (500°F).

A robust and highly accurate temperature data logger designed for use in harsh submersible environments and capable of withstanding temperatures up to 140°C (284°F). In addition, it can achieve an accuracy of ±0.1°C (0.18°F) over a wide temperature range and can store up to 65,536 readings. It features a rigid external probe capable of measuring extended temperature ranges up to 260°C (500°F).

Your Price $539.00 USD
Availability 1 in Stock
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your HiTemp140-1 Temperature Data Logger with 1" probe

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your HiTemp140-1 Temperature Data Logger with 1" probe

MadgeTech HiTemp140-1 Offers

Features

  • Accuracy ±0.1°C (0.18°F)
  • Operates up to 140°C (284°F)
  • Submersible (IP68)
  • User-replaceable battery
  • Rugged
  • Programmable start time
  • Programmable stop time
  • Engraved label
  • 1-inch probe length
  • Battery end-of-life indicator
  • Simple setup and installation
  • Minimal long-term maintenance
  • Long-term field deployment

Applications

  • Autoclave verification
  • Implementation of HACCP programs
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Dishwasher testing
  • Pasteurization


Using MadgeTech 4 software, starting, stopping, and downloading the data logger is simple and easy. To use it, simply place the data logger in the IFC400 or IFC406 docking station (sold separately). With the software, you can choose between immediate or delayed start-up, as well as the read speed. Start the data logger, remove it from the docking station, and the device is ready for deployment. Graphical, tabular, and summary data are provided for analysis, and data can be viewed in °C, °F, K, or °R. Data can also be automatically exported to Excel for further calculations.

  • Multiple graph overlay
  • Statistics
  • Digital calibration
  • Zoom in/zoom out
  • Lethality equations (F0, PU)
  • Mean kinetic temperature
  • Full-time zone support
  • Data annotation
  • Min./max./average lines
  • Summary view

MadgeTech HiTemp140-1 Specifications

Temperature
Temperature Sensor 100 Ω platinum RTD
Probe Measurement Range -200 to 260°C (-328 to 500°F)
Temperature Resolution 0.01°C (0.02°F)
Calibrated Accuracy ±0.1°C/±0.18°F (20 to 140°C/68 to 284°F)
±0.3°C/±0.54°F (-20 to 19.99°C/-4 to 67.98°F)
±0.4°C/±0.72°F (-40 to 20.01°C/-40 to -4.02°F)
General Specifications
Startup modes Programmable immediate startup of the software
Startup delay up to 18 months in advance
Stop modes Manual or timed (specific date and time)
Real-time recording Can be used with a computer to monitor and record data in real time
Password protection An optional password can be programmed into the device to restrict access to configuration options. Data can be read without the password
Memory 65,536 readings
Envelope Yes
Read rate 1 reading every second up to 1 reading every 24 hours
Calibration Digital calibration via software
Calibration date Automatic recording in the device
Battery Type: 3.6 V high-temperature lithium battery included; user-replaceable
Lifespan: Typically 2 years (one-minute reading speed)
Data format Date and time stamped °C, K, °F, or °R
Time accuracy ±1 minute/month at 20 to 30°C (68 to 86°F) (standalone mode)
Computer interface IFC400 or IFC406 USB docking station required; 125,000 baud
Operating system compatibility Windows XP SP3 or later
Software compatibility Standard software version 2.03.06 or later
Secure software version 4.1.3.0 or later
Operating environment -40 to 140°C (-40 to 284°F)
IP rating IP68
Dimensions Body: 40 x 24.6 mm (1.6 x 0.970 in) diameter
Probe: 2.8 x 0.32 cm (1.1 x 0.125 in) diameter (transitional diameter of 0.48 cm [0.188 in])
Weight 120 g (4.2 oz)
Material 316 stainless steel
Approvals CE
Click here for complete specifications on the MadgeTech HiTemp140-1

What's included with the MadgeTech HiTemp140-1

  • MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Click on a category to view a selection of compatible accessories with the MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F.

MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Ask a question about MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Customer Reviews for the MadgeTech HiTemp140-1

MadgeTech HiTemp140-1 Offers

Features

  • Accuracy ±0.1°C (0.18°F)
  • Operates up to 140°C (284°F)
  • Submersible (IP68)
  • User-replaceable battery
  • Rugged
  • Programmable start time
  • Programmable stop time
  • Engraved label
  • 1-inch probe length
  • Battery end-of-life indicator
  • Simple setup and installation
  • Minimal long-term maintenance
  • Long-term field deployment

Applications

  • Autoclave verification
  • Implementation of HACCP programs
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Dishwasher testing
  • Pasteurization


Using MadgeTech 4 software, starting, stopping, and downloading the data logger is simple and easy. To use it, simply place the data logger in the IFC400 or IFC406 docking station (sold separately). With the software, you can choose between immediate or delayed start-up, as well as the read speed. Start the data logger, remove it from the docking station, and the device is ready for deployment. Graphical, tabular, and summary data are provided for analysis, and data can be viewed in °C, °F, K, or °R. Data can also be automatically exported to Excel for further calculations.

  • Multiple graph overlay
  • Statistics
  • Digital calibration
  • Zoom in/zoom out
  • Lethality equations (F0, PU)
  • Mean kinetic temperature
  • Full-time zone support
  • Data annotation
  • Min./max./average lines
  • Summary view

MadgeTech HiTemp140-1 Specifications

Temperature
Temperature Sensor 100 Ω platinum RTD
Probe Measurement Range -200 to 260°C (-328 to 500°F)
Temperature Resolution 0.01°C (0.02°F)
Calibrated Accuracy ±0.1°C/±0.18°F (20 to 140°C/68 to 284°F)
±0.3°C/±0.54°F (-20 to 19.99°C/-4 to 67.98°F)
±0.4°C/±0.72°F (-40 to 20.01°C/-40 to -4.02°F)
General Specifications
Startup modes Programmable immediate startup of the software
Startup delay up to 18 months in advance
Stop modes Manual or timed (specific date and time)
Real-time recording Can be used with a computer to monitor and record data in real time
Password protection An optional password can be programmed into the device to restrict access to configuration options. Data can be read without the password
Memory 65,536 readings
Envelope Yes
Read rate 1 reading every second up to 1 reading every 24 hours
Calibration Digital calibration via software
Calibration date Automatic recording in the device
Battery Type: 3.6 V high-temperature lithium battery included; user-replaceable
Lifespan: Typically 2 years (one-minute reading speed)
Data format Date and time stamped °C, K, °F, or °R
Time accuracy ±1 minute/month at 20 to 30°C (68 to 86°F) (standalone mode)
Computer interface IFC400 or IFC406 USB docking station required; 125,000 baud
Operating system compatibility Windows XP SP3 or later
Software compatibility Standard software version 2.03.06 or later
Secure software version 4.1.3.0 or later
Operating environment -40 to 140°C (-40 to 284°F)
IP rating IP68
Dimensions Body: 40 x 24.6 mm (1.6 x 0.970 in) diameter
Probe: 2.8 x 0.32 cm (1.1 x 0.125 in) diameter (transitional diameter of 0.48 cm [0.188 in])
Weight 120 g (4.2 oz)
Material 316 stainless steel
Approvals CE
Click here for complete specifications on the MadgeTech HiTemp140-1

What's included with the MadgeTech HiTemp140-1

  • MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Click on a category to view a selection of compatible accessories with the MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F.

MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Ask a question about MadgeTech HiTemp140-1 Temperature Data Logger with 1" probe, 284°F

Customer Reviews for the MadgeTech HiTemp140-1

More MadgeTech Products