Measures and records voltage, typically used in conjunction with strain gauges, load cells or other low-level DC voltage sources. Designed to accurately measure and record the output of the gauge to determine parameter levels such as stress, torque, strain, and pressure on a structure or item over a period of time.
Measures and records voltage, typically used in conjunction with strain gauges, load cells or other low-level DC voltage sources. Designed to accurately measure and record the output of the gauge to determine parameter levels such as stress, torque, strain, and pressure on a structure or item over a period of time.
| Bridge Range | ±30 mv, ±150 mv, ±1000 mv |
| Bridge Resolution | ±30 mV: 1 µV ±150 mV: 5 µV ±1000 mV: 50 µV |
| Bridge Accuracy | ±30 mV: ±0.01 %FSR; ±3 MicroVolts ±150 mV: ±0.01 %FSR; 16 Microvolts ±1000 mV: ±0.01 %FSR; 120 Microvolts |
| Memory | 1,000,000 readings; software configurable memory wrap; 330,000 readings in multiple start/stop | |||
| Reading Rate | 4Hz to 1 every 24 hours | |||
| Baud Rate | 115,200 | |||
| Battery Life | 10 months typical at a 1 minute reading rate with a 350 Ω load 2 years typical at a 1 minute reading rate with a 1000 Ω load | |||
| Material | ABS Plastic | |||
| Dimensions | 1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm) | |||
| Operating Environment | -40 °C to +80 °C, 0 %RH to 90 %RH non-condensing | |||
| Required Interface Package | IFC200 | |||
| Nominal Range | ±30 | ±150 | ±1000 | ||||
| Measurement Range | ±30mV | ±160mV | ±1200mV | ||||
| Resolution | 1µV | 5µV | 50µV | ||||
| Calibrated Accuracy | ±0.01% FSR; ±3 Microvolts | ±0.01% FSR; ±16 Microvolts | ±0.01% FSR; ±120 Microvolts | ||||
| Input Range | 0 to 2.5V | ||||||
| Reference Voltage | 2.5V | ||||||