Measure and store up to 32,000 temperature readings with this vaccine kit, featuring a two-socket external probe with an auto channel swap function. This kit comes with a temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
Measure and store up to 32,000 temperature readings with this vaccine kit, featuring a two-socket external probe with an auto channel swap function. This kit comes with a temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
See if temperature excursions have occurred at a glance with this vaccine kit, designed to show the current day and up to the previous 29 days. Additionally, this kit features a built-in alarm if temperature readings are outside pre-set limits.
Features
Applications
External Temperature Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) 0 to 99 % RH (non-condensing) Storage: 32 to 104°F (-10 to 40°C) |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) Better than 0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) Better than 0.9°F (0.5°C) for 140 to 210°F (60 to 99°C) LogTag Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag® |
Sensor Reaction Time | Typically less than 2 minutes(T90) in moving air (1m/s) for ST100S type |
Rated Temperature Reading Accuracy | Better than ±0.9°F(±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F(0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Probe | Connectivity: Up to 2 Compatibility: All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-16.↵ |
Recording Capacity | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics. |
Sampling Interval | Configurable from 30 seconds to 18 hours (Typically 5 minute logging) |
Alarms | Up to 6 individually configurable alarms for each channel Possible to set alarms separately for channel one and channel two |
Logging Start Options | Push button start or specific date and time |
Environmental | IP61 (when vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Typical accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ±0.00294 seconds/day/°C) |
Standard Remote Probe Cable Lengths | Standard: 4’11" (1.5 m) Extended: 9’10" (3 m), recommended maximum |
Remote Probe Cable Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0/micro USB socket |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only) Life: AAA battery up to 12 months - If unit is operated without power supply |
Case Material | Polycarbonate |
Dimensions | 0.7 x 2.83 x 5.55" (18 x 72 x 141 mm) |
Weight | 0.34 lbs (156 g) with AAA batteries, 0.29 lbs (132 g) – excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTRED30-16 Vaccine Kit with two external probes, -40 to 210°F, dual channel.
External Temperature Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) 0 to 99 % RH (non-condensing) Storage: 32 to 104°F (-10 to 40°C) |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) Better than 0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) Better than 0.9°F (0.5°C) for 140 to 210°F (60 to 99°C) LogTag Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag® |
Sensor Reaction Time | Typically less than 2 minutes(T90) in moving air (1m/s) for ST100S type |
Rated Temperature Reading Accuracy | Better than ±0.9°F(±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F(0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Probe | Connectivity: Up to 2 Compatibility: All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-16.↵ |
Recording Capacity | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics. |
Sampling Interval | Configurable from 30 seconds to 18 hours (Typically 5 minute logging) |
Alarms | Up to 6 individually configurable alarms for each channel Possible to set alarms separately for channel one and channel two |
Logging Start Options | Push button start or specific date and time |
Environmental | IP61 (when vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Typical accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ±0.00294 seconds/day/°C) |
Standard Remote Probe Cable Lengths | Standard: 4’11" (1.5 m) Extended: 9’10" (3 m), recommended maximum |
Remote Probe Cable Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0/micro USB socket |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only) Life: AAA battery up to 12 months - If unit is operated without power supply |
Case Material | Polycarbonate |
Dimensions | 0.7 x 2.83 x 5.55" (18 x 72 x 141 mm) |
Weight | 0.34 lbs (156 g) with AAA batteries, 0.29 lbs (132 g) – excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTRED30-16 Vaccine Kit with two external probes, -40 to 210°F, dual channel.