Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Model: EL-USB-ACT

Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Model: EL-USB-ACT

Stand-alone data logger measures and stores up to 127,000 AC/DC current readings. Must be used with an appropriate current clamp to take readings over a 0 to 1000ADC measurement range. In ‘energy monitoring’ mode, this data is converted into power, energy (using a user defined voltage value) and cost (using a user supplied energy unit cost). The millivolt measurement mode allows for direct measurement of voltage, up to 1VDC (707mVAC).

Stand-alone data logger measures and stores up to 127,000 AC/DC current readings. Must be used with an appropriate current clamp to take readings over a 0 to 1000ADC measurement range. In ‘energy monitoring’ mode, this data is converted into power, energy (using a user defined voltage value) and cost (using a user supplied energy unit cost). The millivolt measurement mode allows for direct measurement of voltage, up to 1VDC (707mVAC).

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


AC and DC Millivolt Data Logger with Current Clamp Input

When used with a current clamp, this standalone data logger measures and stores up to 127,232 a.c. and d.c. current readings over a 0 to 1000 amp d.c. measurement range (0 to 723 amps for a.c.). In 'energy monitoring' mode, this data is converted into power, energy (using a user defined voltage value) and cost (using a user supplied energy unit cost). The millivolt measurement mode allows for direct measurement of voltage, up to 1V d.c. (700mV a.c.).

The user can easily set up the logger and view downloaded data by plugging the data logger into a PC's USB port and using the supplied software. The software has provision for a clamp scaling factor (the clamp input-output ratio of amps to millivolts). Stored data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of current, power, energy and cost information. At the touch of a button, the user can cycle between the most recent, maximum and minimum measurement values. The data logger is fitted with 2 replaceable AA batteries.


Features:

  • Compatible with a.c. and d.c. current clamps
  • Energy monitoring mode (to calculate power, cumulative energy and cumulative cost)
  • a.c. and d.c. millivolt measurement mode
  • Logging rates between 1s and 12hr
  • 4mm banana plug inputs

Specifications:

Specification Min. Typ. Max. Unit
Measurement range (a.c.) 0   707 mV a.c. RMS
Equivalent clamp measurement range (a.c.)* 0   723 A a.c.
Accuracy (a.c.)   5   %
Frequency     500 Hz
Measurement range (d.c.) 0   1000 mV d.c.
Equivalent clamp measurement range (d.c.)* 0   1000 A d.c.
Accuracy (d.c.)   2   %
Measurement resolution   250   uV
Equivalent clamp measurement resolution*   250   mA
Display resolution** 1     mA/mV
Logging rate (Current measurement) Every 1s   Every 12hr -
Logging rate (Energy measurement) Every 1s   Every 10s -
Operating temperature range -10 (-31)   +50 (176) °C (°F)
Battery life***     6 Months
Click here for complete specifications on the Lascar EL-USB-ACT

What's included with the Lascar EL-USB-ACT

  • Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Software:

Set up and data download of our EasyLog data loggers is enabled by our EL-WIN-USB software. It is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8.

Download the latest version of the software below. Please note, the software is not compatible with Mac or Linux.

Download Software

Ask a question about Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Customer Reviews for the Lascar EL-USB-ACT

AC and DC Millivolt Data Logger with Current Clamp Input

When used with a current clamp, this standalone data logger measures and stores up to 127,232 a.c. and d.c. current readings over a 0 to 1000 amp d.c. measurement range (0 to 723 amps for a.c.). In 'energy monitoring' mode, this data is converted into power, energy (using a user defined voltage value) and cost (using a user supplied energy unit cost). The millivolt measurement mode allows for direct measurement of voltage, up to 1V d.c. (700mV a.c.).

The user can easily set up the logger and view downloaded data by plugging the data logger into a PC's USB port and using the supplied software. The software has provision for a clamp scaling factor (the clamp input-output ratio of amps to millivolts). Stored data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of current, power, energy and cost information. At the touch of a button, the user can cycle between the most recent, maximum and minimum measurement values. The data logger is fitted with 2 replaceable AA batteries.


Features:

  • Compatible with a.c. and d.c. current clamps
  • Energy monitoring mode (to calculate power, cumulative energy and cumulative cost)
  • a.c. and d.c. millivolt measurement mode
  • Logging rates between 1s and 12hr
  • 4mm banana plug inputs

Specifications:

Specification Min. Typ. Max. Unit
Measurement range (a.c.) 0   707 mV a.c. RMS
Equivalent clamp measurement range (a.c.)* 0   723 A a.c.
Accuracy (a.c.)   5   %
Frequency     500 Hz
Measurement range (d.c.) 0   1000 mV d.c.
Equivalent clamp measurement range (d.c.)* 0   1000 A d.c.
Accuracy (d.c.)   2   %
Measurement resolution   250   uV
Equivalent clamp measurement resolution*   250   mA
Display resolution** 1     mA/mV
Logging rate (Current measurement) Every 1s   Every 12hr -
Logging rate (Energy measurement) Every 1s   Every 10s -
Operating temperature range -10 (-31)   +50 (176) °C (°F)
Battery life***     6 Months
Click here for complete specifications on the Lascar EL-USB-ACT

What's included with the Lascar EL-USB-ACT

  • Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Software:

Set up and data download of our EasyLog data loggers is enabled by our EL-WIN-USB software. It is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8.

Download the latest version of the software below. Please note, the software is not compatible with Mac or Linux.

Download Software

Ask a question about Lascar EL-USB-ACT EasyLog USB AC/DC Millivolt Data Logger

Customer Reviews for the Lascar EL-USB-ACT

More Lascar Products

Calibration Lab