Analyzer measures 02, C0, inlet temperature, flue temperature and differential pressure/draft. It comes with a wireless handset.
Analyzer measures 02, C0, inlet temperature, flue temperature and differential pressure/draft. It comes with a wireless handset.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
The Kane industrial combustion analyzer calculate efficiency, C02, Net temperature differential, Losses, Excess air, C0/C02 ratio, and Poison indeax.
Features
Applications
| Gas Measurement | Pressure</td> | CO2 | Efficiency | O2 | CO | Flue temperature | Inlet temperature |
| Range | 0 to 150 mBar | 0 to Fuel Value | 0 to 100% | 0 to 25% | 2000 ppm | 32° to 2140°F (0 to 1100°C) | 0° to 999°F (0° to 600°C) |
| Resolution | 0.01 mBar | 0.10% | 0.1% | 0.01% | 1 ppm | 0.1° F/C | 0.1° F/C |
| Accuracy | ±0.5% F.S | ±0.3% | ±1% | -0.1% + 0.2% | <100 ppm ±5 ppm >100 ppm <1000 ppm ±5% rdg >2000 ppm <4000 ppm ±10% rdg | 1.8°F (1.0°C) ±0.3% rdg | 1.8°F (1.0°C) ±0.3% rdg |
| Overrange | 4000 ppm |
Click on a category to view a selection of compatible accessories with the Kane K9206C7 Combustion Analyzer, Industrial.
| Gas Measurement | Pressure</td> | CO2 | Efficiency | O2 | CO | Flue temperature | Inlet temperature |
| Range | 0 to 150 mBar | 0 to Fuel Value | 0 to 100% | 0 to 25% | 2000 ppm | 32° to 2140°F (0 to 1100°C) | 0° to 999°F (0° to 600°C) |
| Resolution | 0.01 mBar | 0.10% | 0.1% | 0.01% | 1 ppm | 0.1° F/C | 0.1° F/C |
| Accuracy | ±0.5% F.S | ±0.3% | ±1% | -0.1% + 0.2% | <100 ppm ±5 ppm >100 ppm <1000 ppm ±5% rdg >2000 ppm <4000 ppm ±10% rdg | 1.8°F (1.0°C) ±0.3% rdg | 1.8°F (1.0°C) ±0.3% rdg |
| Overrange | 4000 ppm |
Click on a category to view a selection of compatible accessories with the Kane K9206C7 Combustion Analyzer, Industrial.