INOR MESO-HX (FM) HART Compatible, 2-wire, in-head transmitter

Model: MESO-HX (FM) | Order No: 70MEHX1001

INOR MESO-HX (FM) HART Compatible, 2-wire, in-head transmitter

Model: MESO-HX (FM) | Order No: 70MEHX1001

This unit is the intrinsically safe version for use in Ex-applications. It is fully HART compatible, with communications through the HART protocol.

This unit is the intrinsically safe version for use in Ex-applications. It is fully HART compatible, with communications through the HART protocol.

Your Price $380.00 USD
Availability 2 to 3 Weeks
Quantity

INOR MESO-HX (FM) Offers

MEPRO 2 is a Windows based and user friendly software, which facilitates the access to and use of functions like transmitter configuration, documentation, monitoring and calibration.

Functions

Fully HART® Compatible

  • True on-line communication with hand-held HART Communicator or Windows software MEPRO 2

Input for RTDs, T/Cs, mV and resistance

  • Reduced inventory costs
  • Simplified plant engineering

Efficient customized 50-point linearization

  • Any sensor characteristics can be matched

Sensor diagnostics

  • SmartSense detects low sensor isolation (essential for correct measurements)
  • Selectable sensor break action

Simplified loop check-up

  • The transmitter works as an accurate current generator

On-screen indications of input and output

  • Valuable tools for temporary measurements

Improved QA with data storage

  • Vital information, such as TAG-No., maintenance record etc. can be stored in the nonvolatile memory

Performance and Design

Excellent stability

  • Long-term stability 0.1%/year

Enhanced total system accuracy

  • Sensor error correction (compensates for known sensor errors)

Input-Output isolation 1500 VAC

  • Eliminates measuring errors due to ground loops

High load capacity

  • Only 10 V voltage drop over the transmitter (MESO-H) allows for high loads

Designed for harsh conditions

  • Excellent EMC performance
  • Durable, shockproof design

Simple mounting and connection

  • For DIN B head or larger

Features

  • Fully HART Compatible
  • True on-line communication with hand-held HART Communicator or Windows software MEPRO 2
  • Long-term stability 0.1% per year.
  • Sensor error correction (compensates for known sensor errors).
  • Input-Output isolation 1500 VAC Eliminates measuring errors due to ground loops.
  • Only 10 V voltage drop over the transmitter (MESO-H) allows for high loads.
  • Operation temperature up to 185°F (85°C)
  • Excellent EMC performance.
  • Durable, shockproof design.
  • Simple mounting and connection
  • For DIN B head or larger.
  • 5 year limited warranty
  • Input for RTDs, T/Cs, mV and resistance
  • Efficient customized 50-point linearization

INOR MESO-HX (FM) Specifications

Center Hole Diameter 0.280" (7.00 mm)
Operating Temperature Up to 185°F (85°C)
221°F (105°C) on Request
Click here for complete specifications on the INOR MESO-HX (FM)

What's included with the INOR MESO-HX (FM)

  • Five-Year Limited Warranty

Ask a question about INOR MESO-HX (FM) HART Compatible, 2-wire, in-head transmitter

Customer Reviews for the INOR MESO-HX (FM)

INOR MESO-HX (FM) Offers

MEPRO 2 is a Windows based and user friendly software, which facilitates the access to and use of functions like transmitter configuration, documentation, monitoring and calibration.

Functions

Fully HART® Compatible

  • True on-line communication with hand-held HART Communicator or Windows software MEPRO 2

Input for RTDs, T/Cs, mV and resistance

  • Reduced inventory costs
  • Simplified plant engineering

Efficient customized 50-point linearization

  • Any sensor characteristics can be matched

Sensor diagnostics

  • SmartSense detects low sensor isolation (essential for correct measurements)
  • Selectable sensor break action

Simplified loop check-up

  • The transmitter works as an accurate current generator

On-screen indications of input and output

  • Valuable tools for temporary measurements

Improved QA with data storage

  • Vital information, such as TAG-No., maintenance record etc. can be stored in the nonvolatile memory

Performance and Design

Excellent stability

  • Long-term stability 0.1%/year

Enhanced total system accuracy

  • Sensor error correction (compensates for known sensor errors)

Input-Output isolation 1500 VAC

  • Eliminates measuring errors due to ground loops

High load capacity

  • Only 10 V voltage drop over the transmitter (MESO-H) allows for high loads

Designed for harsh conditions

  • Excellent EMC performance
  • Durable, shockproof design

Simple mounting and connection

  • For DIN B head or larger

Features

  • Fully HART Compatible
  • True on-line communication with hand-held HART Communicator or Windows software MEPRO 2
  • Long-term stability 0.1% per year.
  • Sensor error correction (compensates for known sensor errors).
  • Input-Output isolation 1500 VAC Eliminates measuring errors due to ground loops.
  • Only 10 V voltage drop over the transmitter (MESO-H) allows for high loads.
  • Operation temperature up to 185°F (85°C)
  • Excellent EMC performance.
  • Durable, shockproof design.
  • Simple mounting and connection
  • For DIN B head or larger.
  • 5 year limited warranty
  • Input for RTDs, T/Cs, mV and resistance
  • Efficient customized 50-point linearization

INOR MESO-HX (FM) Specifications

Center Hole Diameter 0.280" (7.00 mm)
Operating Temperature Up to 185°F (85°C)
221°F (105°C) on Request
Click here for complete specifications on the INOR MESO-HX (FM)

What's included with the INOR MESO-HX (FM)

  • Five-Year Limited Warranty

Ask a question about INOR MESO-HX (FM) HART Compatible, 2-wire, in-head transmitter