INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

Model: 721-204-G1

INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

Model: 721-204-G1

D-Tek 3 CO2 Refrigerant Leak Detector 721-204-G1 is an updated version of the Inficon D-Tek with additional features such as an easy-to-change-sensor, quick-charge lithium-ion battery, and a new ergonomic design. This detector only comes with the CO2 sensor for locating leaks on commercial refrigeration systems, restaurant soda machines, or any other systems using R-744.

D-Tek 3 CO2 Refrigerant Leak Detector 721-204-G1 is an updated version of the Inficon D-Tek with additional features such as an easy-to-change-sensor, quick-charge lithium-ion battery, and a new ergonomic design. This detector only comes with the CO2 sensor for locating leaks on commercial refrigeration systems, restaurant soda machines, or any other systems using R-744.

Sale Price $699.99 USD
Regular Price $910.00 USD
Availability 1 Week
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

INFICON 721-204-G1 Offers

Carbon Dioxide (CO2) is being used more and more in commercial applications such as grocery stores, cold rooms, walk-in freezers, industrial cold storage, and food manufacturing/processing. CO2 is less environmentally harmful than many of the previously used gases in these refrigeration applications. However, while beneficial in environmental impact, CO2 is a potentially dangerous gas to humans if high concentrations are present. Therefore, a CO2 refrigerant leak detector is a necessary tool for those service technicians working with these types of systems.
The Inficon D-Tek 3 CO2 refrigerant detector has increased sensitivity and versatility, allowing you to quickly and reliably locate CO2 leaks. This newly redesigned sensor has a sensitivity of 0. 07 oz. (2g/year) as well as having the longest sensor life (1000 hours) in the industry. The new and improved infrared sensor on the D-Tek 3 CO2 detector is easy to remove and replace in the field.
While the Inficon D-Tek 3 CO2 Refrigerant Leak Detector only includes a CO2 sensor, you can purchase the refrigerant sensor (p/n 724-701-G1), which will detect CFC, HCFCs, HFCs, HFOs, and blends, giving you two instruments in one.
A new and intuitive interface allows you to switch between operating mode and sensitivity level. Pinpoint mode zeroes to the background refrigerant automatically and has four different sensitivity levels to help you pinpoint leaks of any size. The manual mode allows you to manually zero to the background refrigerant with the press of a button; the alarm will not sound unless higher concentrations of refrigerant are detected.
The hydrophobic filter on the Inficon CO2 refrigerant leak detector allows air and refrigerants to pass through while filtering out water, dirt, and oil to ensure the sensor stays clean. Need a longer probe to check those hard-to-reach area? The D-Tek 3 CO2 leak detector includes a standard 17 probe, which is easy to remove, so you can quickly install the optional extra-long probe (27) for those hard-to-reach areas.
The D-Tek 3 721-204-G1 is powered by a quick-charge lithium-ion battery that lasts up to 10 hours with just a three-hour charge time.

Top 5 Reasons to own a D-TEK 3 Refrigerant Leak Detector:
1) High sensitivity: D-TEK 3 is highly sensitive to all refrigerants including CFCs, HCFCs, HFCs and HFOs.
2) Long-lasting sensor: The all-new, redesigned infrared sensor is among the longest lasting in the industry and does not degrade over time - making your leak detector as accurate and reliable as it was on day one until the day the sensor dies.
3) A2L certified: No need to carry an extra tool on A2L jobs - D-TEK 3 is certified for use with A2L semi-flammable refrigerants, such as R1234yf and R134a.
4) Field-replaceable components: Minimize downtime with D-TEK 3's field-replaceable sensor and rechargeable lithium ion battery.
5) 3-in-1 versatility: Swap D-TEK 3's refrigerant sensor for the optional flammable refrigerant sensor or CO2 sensor to detect almost any type of refrigerant - using one tool!
Advantages: Longest sensor life in the industry.

Features

  • Sensitivity of 0.07 oz/year (2 g/year)
  • CO2 sensor
  • 1000 hour sensor life
  • Easy field replacement
  • Automatic and manual zero point
  • 4 sensitivity levels: Low, Medium, High, and Super sensitivity settings
  • Designed for ergonomic comfort
  • Lithium ion battery
  • Lithium-ion battery quick charge capability
  • Lithium-ion battery field replacement
  • New Long life (~10 hours) lithium-ion battery
  • Automatic and manual zero modes
  • Low, Medium, High, and Super sensitivity settings
  • Automatic and manual zero modes
  • Optional extra-long probe for hard-to-reach areas
  • All new, redesigned infrared sensor
  • Longest sensor life in the industry
  • Refrigerant sensor field replacement

Applications

  • CO2 refrigeration service.
  • Carbonated beverage delivery systems.
  • Wineries, breweries, and bakeries.
  • Bulk CO2 manufacturing, delivery, and service.
  • General leak detection (using CO2 as test gas).

INFICON 721-204-G1 Specifications

Usage Indoor/outdoor
Sensor Type Infrared
Compatible Refrigerants R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a/b, R454a/b, R507 (AZ50), R1234yf/ze and more
Probe Length 17" (43 cm)
Sensitivity to R744 (CO2) 0.07 oz./yr. (2 g/a)
Battery Type Lithium ion battery (rechargeable)
Charging Input Type Micro USB (can operate while charging)
Battery Life ~10 hours
Warm-Up Period 45 to 90 seconds
Operating Temperature -4 to 122°F (-20 to 50°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Charging Temperature 32 to 113°F (0 to 45°C)
Humidity 95% RH NC maximum
Certifications EN14624:2020, A2L certified, CE, UKCA
Weight 0.97 lbs (440g)
Patents (pending) Application #10 2018 208 826.8

What's included with the INFICON 721-204-G1

  • CO2 Refrigerant Leak Detector
  • Infrared CO2 Sensor
  • Lithium-Ion Battery
  • Spare Filters
  • Ac Wall Charger
  • Carrying Case
  • Two-Year Over The Counter Warranty

Click on a category to view a selection of compatible accessories with the INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector.

INFICON 033-0019-G1 Charging Adapter and Cord, 120V 033-0019-G1
120-volt Adapter and Cord.




INFICON 716-703-G1 Sensor Access Door 716-703-G1
Sensor access door.




INFICON 716-702-G1 Storage Case 716-702-G1
Storage case.




INFICON 716-701-G1 CO2 Sensor Infrared Cell 716-701-G1
CO2 infrared cell (sensor).




INFICON 703-055-P1 Power Cord with Car Adapter 703-055-P1
12-volt Power Cord with cigarette plug is compatible with Inficon D-TEK Select Refrigerant Leak Detectors.




INFICON 712-700-G1 Power Stick Rechargeable NiMH Battery 712-700-G1
NiMH Battery Power Stick is a replacement part for the Inficon Compass and D-TEK CO2 refrigerant leak detectors.




INFICON 712-701-G1 Infrared Cell Sensor Replacement 712-701-G1
Infrared Cell Sensor Replacement is compatible with Inficon D-TEK Select Refrigerant Leak Detector.












INFICON 712-706-G1 Replaceable Filter Upgrade Kit 712-706-G1
Filter Upgrade Kit (includes base, cap and filter cartridges) for '04/'05 models of Inficon D-TEK Select Refrigerant Leak Detectors.




INFICON 712-707-G1 Replacement Filter Cartridge Kit 712-707-G1
Filter Cartridge Kit (contains 5 filters).




INFICON 724-701-G3 Flammable Refrigerant Sensor for the D-TEK series 724-701-G3
Flammable refrigerant sensor for detecting R290, R600a, and R441a gases. Designed for use with INFICON refrigerant leak detection systems.




INFICON 721-604-G1 Battery and Charging Cradle Bundle for the D-TEK series 721-604-G1
Battery and charging cradle bundle for INFICON D-TEK series refrigerant leak detectors. It provides convenient power management and charging.




INFICON 724-706-G1 Probe Gasket for the D-TEK series, 3-pack 724-706-G1
Probe gaskets designed for use with INFICON's D-TEK 3 and stratus refrigerant leak detectors. These gaskets ensure a secure seal between the probe and the detector, coming in a pack of 3.




INFICON 724-700-G1 Carrying Case 724-700-G1
Compatible with the D-TEK® 3, D-TEK Stratus®, and AST300PPM, this durable and purpose-built carrying case is designed to safely store and transport refrigerant leak detectors ensuring a secure fit and reliable protection for your equipment in the field.




INFICON 721-607-G1 Earbuds 721-607-G1
Compatible with the D-TEK® 3, D-TEK Stratus®, AST300PPM, and AST200IR refrigerant leak detectors, these earbuds are designed to deliver clear and reliable audio feedback during leak detection.




INFICON 703-080-G29 TEK-Check™ Reference Leak, R600a 703-080-G29
Providing a reliable and continuous R600a refrigerant leak for over two years, this reference leak offers an easy and dependable way to verify the performance of your leak detectors. In addition, this compact and user-friendly reference source ensures your instruments remain accurate and operational, making it a safe and convenient accessory for routine leak detector checks.




INFICON 703-080-G10 TEK-Check™ Reference Leak, R134a 703-080-G10
Providing a reliable and continuous R134a refrigerant leak for over two years, this reference leak offers an easy and dependable way to verify the performance of your leak detectors. In addition, this compact and user-friendly reference source ensures your instruments remain accurate and operational, making it a safe and convenient accessory for routine leak detector checks.




INFICON 721-606-G1 Wall Charger with USB cable, US and international 721-606-G1
Designed for global use, this wall charger with USB cable ensures reliable power delivery to your refrigerant leak detection tools. Additionally, this versatile charger is compatible with multiple detector models, making it an essential accessory for both U.S. and international service professionals.




Ask a question about INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

Customer Reviews for the INFICON 721-204-G1

INFICON 721-204-G1 Offers

Carbon Dioxide (CO2) is being used more and more in commercial applications such as grocery stores, cold rooms, walk-in freezers, industrial cold storage, and food manufacturing/processing. CO2 is less environmentally harmful than many of the previously used gases in these refrigeration applications. However, while beneficial in environmental impact, CO2 is a potentially dangerous gas to humans if high concentrations are present. Therefore, a CO2 refrigerant leak detector is a necessary tool for those service technicians working with these types of systems.
The Inficon D-Tek 3 CO2 refrigerant detector has increased sensitivity and versatility, allowing you to quickly and reliably locate CO2 leaks. This newly redesigned sensor has a sensitivity of 0. 07 oz. (2g/year) as well as having the longest sensor life (1000 hours) in the industry. The new and improved infrared sensor on the D-Tek 3 CO2 detector is easy to remove and replace in the field.
While the Inficon D-Tek 3 CO2 Refrigerant Leak Detector only includes a CO2 sensor, you can purchase the refrigerant sensor (p/n 724-701-G1), which will detect CFC, HCFCs, HFCs, HFOs, and blends, giving you two instruments in one.
A new and intuitive interface allows you to switch between operating mode and sensitivity level. Pinpoint mode zeroes to the background refrigerant automatically and has four different sensitivity levels to help you pinpoint leaks of any size. The manual mode allows you to manually zero to the background refrigerant with the press of a button; the alarm will not sound unless higher concentrations of refrigerant are detected.
The hydrophobic filter on the Inficon CO2 refrigerant leak detector allows air and refrigerants to pass through while filtering out water, dirt, and oil to ensure the sensor stays clean. Need a longer probe to check those hard-to-reach area? The D-Tek 3 CO2 leak detector includes a standard 17 probe, which is easy to remove, so you can quickly install the optional extra-long probe (27) for those hard-to-reach areas.
The D-Tek 3 721-204-G1 is powered by a quick-charge lithium-ion battery that lasts up to 10 hours with just a three-hour charge time.

Top 5 Reasons to own a D-TEK 3 Refrigerant Leak Detector:
1) High sensitivity: D-TEK 3 is highly sensitive to all refrigerants including CFCs, HCFCs, HFCs and HFOs.
2) Long-lasting sensor: The all-new, redesigned infrared sensor is among the longest lasting in the industry and does not degrade over time - making your leak detector as accurate and reliable as it was on day one until the day the sensor dies.
3) A2L certified: No need to carry an extra tool on A2L jobs - D-TEK 3 is certified for use with A2L semi-flammable refrigerants, such as R1234yf and R134a.
4) Field-replaceable components: Minimize downtime with D-TEK 3's field-replaceable sensor and rechargeable lithium ion battery.
5) 3-in-1 versatility: Swap D-TEK 3's refrigerant sensor for the optional flammable refrigerant sensor or CO2 sensor to detect almost any type of refrigerant - using one tool!
Advantages: Longest sensor life in the industry.

Features

  • Sensitivity of 0.07 oz/year (2 g/year)
  • CO2 sensor
  • 1000 hour sensor life
  • Easy field replacement
  • Automatic and manual zero point
  • 4 sensitivity levels: Low, Medium, High, and Super sensitivity settings
  • Designed for ergonomic comfort
  • Lithium ion battery
  • Lithium-ion battery quick charge capability
  • Lithium-ion battery field replacement
  • New Long life (~10 hours) lithium-ion battery
  • Automatic and manual zero modes
  • Low, Medium, High, and Super sensitivity settings
  • Automatic and manual zero modes
  • Optional extra-long probe for hard-to-reach areas
  • All new, redesigned infrared sensor
  • Longest sensor life in the industry
  • Refrigerant sensor field replacement

Applications

  • CO2 refrigeration service.
  • Carbonated beverage delivery systems.
  • Wineries, breweries, and bakeries.
  • Bulk CO2 manufacturing, delivery, and service.
  • General leak detection (using CO2 as test gas).

INFICON 721-204-G1 Specifications

Usage Indoor/outdoor
Sensor Type Infrared
Compatible Refrigerants R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a/b, R454a/b, R507 (AZ50), R1234yf/ze and more
Probe Length 17" (43 cm)
Sensitivity to R744 (CO2) 0.07 oz./yr. (2 g/a)
Battery Type Lithium ion battery (rechargeable)
Charging Input Type Micro USB (can operate while charging)
Battery Life ~10 hours
Warm-Up Period 45 to 90 seconds
Operating Temperature -4 to 122°F (-20 to 50°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Charging Temperature 32 to 113°F (0 to 45°C)
Humidity 95% RH NC maximum
Certifications EN14624:2020, A2L certified, CE, UKCA
Weight 0.97 lbs (440g)
Patents (pending) Application #10 2018 208 826.8

What's included with the INFICON 721-204-G1

  • CO2 Refrigerant Leak Detector
  • Infrared CO2 Sensor
  • Lithium-Ion Battery
  • Spare Filters
  • Ac Wall Charger
  • Carrying Case
  • Two-Year Over The Counter Warranty

Click on a category to view a selection of compatible accessories with the INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector.

INFICON 033-0019-G1 Charging Adapter and Cord, 120V 033-0019-G1
120-volt Adapter and Cord.




INFICON 716-703-G1 Sensor Access Door 716-703-G1
Sensor access door.




INFICON 716-702-G1 Storage Case 716-702-G1
Storage case.




INFICON 716-701-G1 CO2 Sensor Infrared Cell 716-701-G1
CO2 infrared cell (sensor).




INFICON 703-055-P1 Power Cord with Car Adapter 703-055-P1
12-volt Power Cord with cigarette plug is compatible with Inficon D-TEK Select Refrigerant Leak Detectors.




INFICON 712-700-G1 Power Stick Rechargeable NiMH Battery 712-700-G1
NiMH Battery Power Stick is a replacement part for the Inficon Compass and D-TEK CO2 refrigerant leak detectors.




INFICON 712-701-G1 Infrared Cell Sensor Replacement 712-701-G1
Infrared Cell Sensor Replacement is compatible with Inficon D-TEK Select Refrigerant Leak Detector.












INFICON 712-706-G1 Replaceable Filter Upgrade Kit 712-706-G1
Filter Upgrade Kit (includes base, cap and filter cartridges) for '04/'05 models of Inficon D-TEK Select Refrigerant Leak Detectors.




INFICON 712-707-G1 Replacement Filter Cartridge Kit 712-707-G1
Filter Cartridge Kit (contains 5 filters).




INFICON 724-701-G3 Flammable Refrigerant Sensor for the D-TEK series 724-701-G3
Flammable refrigerant sensor for detecting R290, R600a, and R441a gases. Designed for use with INFICON refrigerant leak detection systems.




INFICON 721-604-G1 Battery and Charging Cradle Bundle for the D-TEK series 721-604-G1
Battery and charging cradle bundle for INFICON D-TEK series refrigerant leak detectors. It provides convenient power management and charging.




INFICON 724-706-G1 Probe Gasket for the D-TEK series, 3-pack 724-706-G1
Probe gaskets designed for use with INFICON's D-TEK 3 and stratus refrigerant leak detectors. These gaskets ensure a secure seal between the probe and the detector, coming in a pack of 3.




INFICON 724-700-G1 Carrying Case 724-700-G1
Compatible with the D-TEK® 3, D-TEK Stratus®, and AST300PPM, this durable and purpose-built carrying case is designed to safely store and transport refrigerant leak detectors ensuring a secure fit and reliable protection for your equipment in the field.




INFICON 721-607-G1 Earbuds 721-607-G1
Compatible with the D-TEK® 3, D-TEK Stratus®, AST300PPM, and AST200IR refrigerant leak detectors, these earbuds are designed to deliver clear and reliable audio feedback during leak detection.




INFICON 703-080-G29 TEK-Check™ Reference Leak, R600a 703-080-G29
Providing a reliable and continuous R600a refrigerant leak for over two years, this reference leak offers an easy and dependable way to verify the performance of your leak detectors. In addition, this compact and user-friendly reference source ensures your instruments remain accurate and operational, making it a safe and convenient accessory for routine leak detector checks.




INFICON 703-080-G10 TEK-Check™ Reference Leak, R134a 703-080-G10
Providing a reliable and continuous R134a refrigerant leak for over two years, this reference leak offers an easy and dependable way to verify the performance of your leak detectors. In addition, this compact and user-friendly reference source ensures your instruments remain accurate and operational, making it a safe and convenient accessory for routine leak detector checks.




INFICON 721-606-G1 Wall Charger with USB cable, US and international 721-606-G1
Designed for global use, this wall charger with USB cable ensures reliable power delivery to your refrigerant leak detection tools. Additionally, this versatile charger is compatible with multiple detector models, making it an essential accessory for both U.S. and international service professionals.




Ask a question about INFICON 721-204-G1 D-Tek 3 CO2 Refrigerant Leak Detector

Customer Reviews for the INFICON 721-204-G1

More INFICON Products

Calibration Lab