D-Tek 3 Refrigerant Leak Detector is an updated version of the Inficon D-Tek with additional features such as an easy-to-change-sensor, quick-charge lithium-ion battery and a new ergonomic design. Plus, a new optional CO2 sensor that gives a service technician two instruments in one and the versatility to handle everyday refrigeration and air conditioning maintenance and repairs for both residential and commercial facilities. In addition, the D-TEK 3 also has an optional sensor for flammable refrigerants (p/n 724-701-G3) such as R290, R600a, and R441a.
D-Tek 3 Refrigerant Leak Detector is an updated version of the Inficon D-Tek with additional features such as an easy-to-change-sensor, quick-charge lithium-ion battery and a new ergonomic design. Plus, a new optional CO2 sensor that gives a service technician two instruments in one and the versatility to handle everyday refrigeration and air conditioning maintenance and repairs for both residential and commercial facilities. In addition, the D-TEK 3 also has an optional sensor for flammable refrigerants (p/n 724-701-G3) such as R290, R600a, and R441a.
Longest sensor life in the industry and easy field replacement. Plus, a new optional CO2 sensor that gives a service technician two instruments in one and the versatility to handle everyday refrigeration and air conditioning maintenance and repairs for both residential and commercial facilities. In addition, the D-TEK 3 also has an optional sensor for flammable refrigerants (p/n 724-701-G3) such as R290, R600a, and R441a.
The Inficon D-TEK 3 makes it quick and easy to switch to one of the optional sensors to look for refrigerant CO2 or flammable refrigerant leaks and automatically recognizes when a different sensor has been installed.
Top 5 Reasons to own a D-TEK 3 Refrigerant Leak Detector
1) High sensitivity: D-TEK 3 is highly sensitive to all refrigerants including CFCs, HCFCs, HFCs and HFOs.
2) Long-lasting sensor: The all-new, redesigned infrared sensor is among the longest-lasting in the industry and does not degrade over time - making your leak detector as accurate and reliable as it was on day one until the day the sensor dies.
3) A2L certified: No need to carry an extra tool on A2L jobs - D-TEK 3 is certified for use with A2L semi-flammable refrigerants, such as R1234yf and R134a.
4) Field-replaceable components: Minimize downtime with D-TEK 3's field-replaceable sensor and rechargeable lithium-ion battery.
5) 3-in-1 versatility: Swap D-TEK 3's refrigerant sensor for the optional flammable refrigerant sensor or CO2 sensor to detect almost any type of refrigerant - using one tool!
Advantage: Longest sensor life in the industry.
Overview:
One of the most important requirements when using a leak detector is the sensor sensitivity. The Inficon D-Tek 3 leak detector has increased sensitivity and versatility allowing you to quickly and reliably locate CFCs, HCFCs, HFC, HFOs, and blends (including A2Ls). The D-Tek 3 infrared refrigerant leak detector uses an all-new infrared sensor that is easy to remove and replace in the field. This newly redesigned sensor has a sensitivity of 0. 03 oz. /yr (1g/yr) as well as having the longest sensor life (1000 hours) in the industry. In addition to the standard sensor, Inficon also offers a CO2-specific sensor for the D-Tek 3 for refrigeration and air conditioning applications (not included - p/n 721-204-G1). Both sensors are easily changed out while in the field. A new and intuitive interface allows you to easily switch between operating modes or sensitivity levels. Pinpoint mode zeroes to the background refrigerant automatically and has four different sensitivity levels to help you pinpoint leaks of any size. The manual mode allows you to manually zero to the background refrigerant with the press of a button and the alarm will not sound unless higher concentrations of refrigerant are detected. The hydrophobic filter on the Inficon refrigerant leak detector allows air and refrigerants to pass through while filtering out water, dirt, and oil to ensure the sensor stays clean. Need a longer probe to check those hard-to-reach areas? The D-Tek 3 standard 17 probe is easy to remove so you can quickly install the optional extra-long probe (27) for those hard-to-reach areas.
The D-Tek 3 721-202-G1 is powered by a quick-charge lithium-ion battery that lasts up to 10 hours with just a three-hour charge time.
Available Inficon D-Tek 3 Refrigerant Leak Detector 721-204-G1 with CO2 Sensor.
Features
Applications
Usage | Indoor/outdoor |
Sensor Type | Infrared |
Compatible Refrigerants | All CFCs, HCFCs, HFCs, HFOs, and blends (including A2Ls) R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a/b, R454a/b, R507 (AZ50), R1234yf/ze and more |
Minimum Sensitivity (pinpoint mode, Super sensitivity) | 0.03 oz./yr. (1 g/yr.) |
Battery Type | Lithium ion battery (rechargeable) |
Charging Input Type | Micro USB (can operate while charging) |
Battery Life | ~10 hours |
Warm-Up Period | 45-90 seconds |
Operating Temperature | -4 to 122°F (-20 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Charging Temperature | 32 to 113°F (0 to 45°C) |
Humidity | 95% RH NC maximum |
Sensitivity per EN14624 | 1 g/yr. |
Sensitivity for R744 (CO2) | 0.07 oz./yr. (2 g/yr.) (requires CO2 sensor) |
Certifications | EN14624:2020, A2L certified, CE, UKCA |
Patents (pending) | Application #10 2018 208 826.8 |
Probe Length | ~17" (43 cm) |
Weight | 0.97 lbs (440 g) |
Click on a category to view a selection of compatible accessories with the INFICON 721-202-G1 D-Tek 3 Refrigerant Leak Detector.
Usage | Indoor/outdoor |
Sensor Type | Infrared |
Compatible Refrigerants | All CFCs, HCFCs, HFCs, HFOs, and blends (including A2Ls) R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a/b, R454a/b, R507 (AZ50), R1234yf/ze and more |
Minimum Sensitivity (pinpoint mode, Super sensitivity) | 0.03 oz./yr. (1 g/yr.) |
Battery Type | Lithium ion battery (rechargeable) |
Charging Input Type | Micro USB (can operate while charging) |
Battery Life | ~10 hours |
Warm-Up Period | 45-90 seconds |
Operating Temperature | -4 to 122°F (-20 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Charging Temperature | 32 to 113°F (0 to 45°C) |
Humidity | 95% RH NC maximum |
Sensitivity per EN14624 | 1 g/yr. |
Sensitivity for R744 (CO2) | 0.07 oz./yr. (2 g/yr.) (requires CO2 sensor) |
Certifications | EN14624:2020, A2L certified, CE, UKCA |
Patents (pending) | Application #10 2018 208 826.8 |
Probe Length | ~17" (43 cm) |
Weight | 0.97 lbs (440 g) |
Click on a category to view a selection of compatible accessories with the INFICON 721-202-G1 D-Tek 3 Refrigerant Leak Detector.