Honeywell BW 301C Commercial Gas Detection Controller with data logging and Title 24 compliance, 96 transmitters, 126 zones

Model: 301C24-DLC

Honeywell BW 301C Commercial Gas Detection Controller with data logging and Title 24 compliance, 96 transmitters, 126 zones

Model: 301C24-DLC

Designed for simple installation and operation, this Title 24-compliant controller continuously monitors and controls toxic/combustible gases and oxygen hazards and has data logging capabilities. In addition, with an addressable RS-485 communication, it uses daisy chain wiring to connect up to 96 transmitters in three loops.

Designed for simple installation and operation, this Title 24-compliant controller continuously monitors and controls toxic/combustible gases and oxygen hazards and has data logging capabilities. In addition, with an addressable RS-485 communication, it uses daisy chain wiring to connect up to 96 transmitters in three loops.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Controllers category for similar products.

Or let's do a search and help you find what you need:


BW 301C24-DLC Offers

Rely on this gas detection controller for safety, energy efficiency, and easy installation of your gas detection network. In addition, with flexible logic capabilities, this controller reduces operational costs.

Features

  • Continuously monitors and controls toxic, combustible, and refrigerant gases as well as oxygen
  • User friendly
  • Zero maintenance
  • Automatic quick self-test and warm-up
  • Continuous alphanumeric display
  • Inexpensive, reliable, and energy efficient
  • Low installation costs
  • Allows for up to 126 zoning groups which can save energy and extend fan and relay life
  • Manages up to 180 events with programmable latching alarms
  • California Title 24 network option
  • Flexible operation
  • Interchangeable transmitters able to detect different gases
  • Expands to handle up to 96 transmitters or relay modules
  • Programmable time delays
  • Integrated time clock enables scheduling of system operations
  • A full array of visual indicators and integrated 65 dBA alarm levels
  • Fully programmable relays (can be set as fail-safe or not)

Zoning/averaging

This controller offers unique zoning capabilities which permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not activate relays. For example, a car idling in a parking structure may locally increase reading at a nearby transmitter. Rather than activating a fan as a result of the temporary localized fluctuation, zoning can be used to limit relay activation until the average reading for a zone exceeds a set point. This can reduce the run time of fans, yielding savings in both energy usage and wear and tear. This commercial gas detection controller has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters that can be associated with up to 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.

Applications

  • Commercial gas detection
  • Parking structures
  • Boiler rooms
  • Data logging option

BW 301C24-DLC Specifications

Use Controller for centralized gas detection monitoring with real-time gas reading, selective alarm activation and low-cost installation
Network Capacity Three RS-485 channels for up to 96 transmitter inputs
Communication Line Lengths Up to 2000' (609 m) per channel
T-Tap: 65' (20 m), the maximum per T-Tap
130' (40 m), the maximum for all T-Tap combined
Relay Output 5 A, 30 V DC or 250 V AC (resistive load)
Alarm Levels Four fully programmable alarm levels
Time Delays 0, 30, 45 seconds, 1 to 99 minutes before and after the alarm
Outputs 4 x DPDT relays (alarms and/or fault); 65 dBA buzzer
Events Flexible programming that can include: alarms, gas concentrations, faults, real-time clock, voting, optional outlier detection, and time since calibration
Security Password protection for tamper resistance
Zoning Up to 126 programmable zones
Memory 2 GB removable SD card for configuration, readings, and events
Display Large 122 x 32 dot matrix display
Operating Temperature Range -4 to 122°F (-20 to 50°C)
Operating Humidity Range 0 to 95% RH (non-condensing)
Power Requirement 17 to 27 V AC, 24 to 38 V DC, 500 mA
Ratings and Certification Certified to:
For USA: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements (ANSI/UL 61010-1, 2nd edition, dated July 12, 2004, including revisions through October 28, 2008)
For Canada: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements (CAN/CSA C22.2 No. 61010-1:04, 2nd edition, dated July 12, 2004, including general instruction 1 - October 2008 (reaffirmed 2009))

Certified by:
Intertek

Designed to comply with:
IEC 61010-1:2010 (third edition)
California Title 24, Part 6, and associated administrative regulations in Part 1
Dimensions 11 x 8 x 2.8" (28 x 20.3 x 7 cm)
Weight 2.4 lbs (1.1 kg)
Click here for complete specifications on the BW 301C24-DLC

What's included with the BW 301C24-DLC

  • Controller
  • One-Year Warranty

Ask a question about Honeywell BW 301C Commercial Gas Detection Controller with data logging and Title 24 compliance, 96 transmitters, 126 zones

Customer Reviews for the BW 301C24-DLC

BW 301C24-DLC Offers

Rely on this gas detection controller for safety, energy efficiency, and easy installation of your gas detection network. In addition, with flexible logic capabilities, this controller reduces operational costs.

Features

  • Continuously monitors and controls toxic, combustible, and refrigerant gases as well as oxygen
  • User friendly
  • Zero maintenance
  • Automatic quick self-test and warm-up
  • Continuous alphanumeric display
  • Inexpensive, reliable, and energy efficient
  • Low installation costs
  • Allows for up to 126 zoning groups which can save energy and extend fan and relay life
  • Manages up to 180 events with programmable latching alarms
  • California Title 24 network option
  • Flexible operation
  • Interchangeable transmitters able to detect different gases
  • Expands to handle up to 96 transmitters or relay modules
  • Programmable time delays
  • Integrated time clock enables scheduling of system operations
  • A full array of visual indicators and integrated 65 dBA alarm levels
  • Fully programmable relays (can be set as fail-safe or not)

Zoning/averaging

This controller offers unique zoning capabilities which permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not activate relays. For example, a car idling in a parking structure may locally increase reading at a nearby transmitter. Rather than activating a fan as a result of the temporary localized fluctuation, zoning can be used to limit relay activation until the average reading for a zone exceeds a set point. This can reduce the run time of fans, yielding savings in both energy usage and wear and tear. This commercial gas detection controller has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters that can be associated with up to 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.

Applications

  • Commercial gas detection
  • Parking structures
  • Boiler rooms
  • Data logging option

BW 301C24-DLC Specifications

Use Controller for centralized gas detection monitoring with real-time gas reading, selective alarm activation and low-cost installation
Network Capacity Three RS-485 channels for up to 96 transmitter inputs
Communication Line Lengths Up to 2000' (609 m) per channel
T-Tap: 65' (20 m), the maximum per T-Tap
130' (40 m), the maximum for all T-Tap combined
Relay Output 5 A, 30 V DC or 250 V AC (resistive load)
Alarm Levels Four fully programmable alarm levels
Time Delays 0, 30, 45 seconds, 1 to 99 minutes before and after the alarm
Outputs 4 x DPDT relays (alarms and/or fault); 65 dBA buzzer
Events Flexible programming that can include: alarms, gas concentrations, faults, real-time clock, voting, optional outlier detection, and time since calibration
Security Password protection for tamper resistance
Zoning Up to 126 programmable zones
Memory 2 GB removable SD card for configuration, readings, and events
Display Large 122 x 32 dot matrix display
Operating Temperature Range -4 to 122°F (-20 to 50°C)
Operating Humidity Range 0 to 95% RH (non-condensing)
Power Requirement 17 to 27 V AC, 24 to 38 V DC, 500 mA
Ratings and Certification Certified to:
For USA: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements (ANSI/UL 61010-1, 2nd edition, dated July 12, 2004, including revisions through October 28, 2008)
For Canada: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements (CAN/CSA C22.2 No. 61010-1:04, 2nd edition, dated July 12, 2004, including general instruction 1 - October 2008 (reaffirmed 2009))

Certified by:
Intertek

Designed to comply with:
IEC 61010-1:2010 (third edition)
California Title 24, Part 6, and associated administrative regulations in Part 1
Dimensions 11 x 8 x 2.8" (28 x 20.3 x 7 cm)
Weight 2.4 lbs (1.1 kg)
Click here for complete specifications on the BW 301C24-DLC

What's included with the BW 301C24-DLC

  • Controller
  • One-Year Warranty