The battery cell voltage generator accurately evaluates the performance of battery management systems (BMSs) used in lithium-ion battery packs found in electric vehicles (xEVs) and storage batteries. It also features high-precision voltage and current measurement capabilities.
The battery cell voltage generator accurately evaluates the performance of battery management systems (BMSs) used in lithium-ion battery packs found in electric vehicles (xEVs) and storage batteries. It also features high-precision voltage and current measurement capabilities.
The system's simple architecture makes building an environment for validating BMS (*1) functionality safer, more affordable and more productive than ever before.
Features
Applications
| Number of Channels | 12 |
| Maximum in-series Connections | In-series connections of instrument up to and including a maximum in-series output voltage of 1000 V |
| Output Range | DC voltage: 0.0000 V to 5.0250 V (set independently for all channels) Maximum output current: ±1.00000 A (set independently for all channels) |
| Measurement Range | DC voltage: -0.00100 V to 5.10000 V DC current (2-range architecture): ±1.20000 A (1 A range) ±120.0000 μA (100 μA range) |
| Integration Time | 1 PLC (50 Hz: 20 ms; 60 Hz: 16.7 ms) × number of smoothing iterations (user-configured) |
| Voltage Output Accuracy | ±0.0150% of setting ±500 μV |
| Voltage Measurement Accuracy | ±0.0100% of reading ±100 μV |
| Current Measurement Accuracy | 1 A range: ±0.0700% of reading ±100 μA 100 μA range: ±0.0350% of reading ±10 nA |
| Interfaces | LAN |
| Power Supply | Universal (100 V to 240 V AC), 50 Hz / 60 Hz |
| Dimensions | 16.93 x 5.2 x 19.02" (43 x 13.21 x 48.31 cm) |
| Weight | 363.3 oz (10.3 kg) |
| Number of Channels | 12 |
| Maximum in-series Connections | In-series connections of instrument up to and including a maximum in-series output voltage of 1000 V |
| Output Range | DC voltage: 0.0000 V to 5.0250 V (set independently for all channels) Maximum output current: ±1.00000 A (set independently for all channels) |
| Measurement Range | DC voltage: -0.00100 V to 5.10000 V DC current (2-range architecture): ±1.20000 A (1 A range) ±120.0000 μA (100 μA range) |
| Integration Time | 1 PLC (50 Hz: 20 ms; 60 Hz: 16.7 ms) × number of smoothing iterations (user-configured) |
| Voltage Output Accuracy | ±0.0150% of setting ±500 μV |
| Voltage Measurement Accuracy | ±0.0100% of reading ±100 μV |
| Current Measurement Accuracy | 1 A range: ±0.0700% of reading ±100 μA 100 μA range: ±0.0350% of reading ±10 nA |
| Interfaces | LAN |
| Power Supply | Universal (100 V to 240 V AC), 50 Hz / 60 Hz |
| Dimensions | 16.93 x 5.2 x 19.02" (43 x 13.21 x 48.31 cm) |
| Weight | 363.3 oz (10.3 kg) |