Designed to provide safe and accurate measurements, this power logger measures single to 3-phase 4-wire circuits. Capable of measuring 90 to 780 V, this logger also stores data on SD or SDHC cards, and its Quick Set function provides an on-screen guide to ensure that you make the correct connection. Clamps are sold separately.
Designed to provide safe and accurate measurements, this power logger measures single to 3-phase 4-wire circuits. Capable of measuring 90 to 780 V, this logger also stores data on SD or SDHC cards, and its Quick Set function provides an on-screen guide to ensure that you make the correct connection. Clamps are sold separately.
Features
Measurement | Line: 50/60 Hz Circuits: Single-phase 2-wire (1/2/3 circuits), single-phase 3-wire (1 circuit), 3-phase 3-wire (1 circuit), 3-phase 4 wires (1 circuit) |
Number of Channels | 1 to 3 (current only) |
Measurement Items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input |
Range | Voltage: 600 VAC (effective measurement range: 90 to 780 V) Current: 500 mA to 5 kA AC (depends on current sensor in use), 50 mA to 5 A AC (leak clamp on sensor only) Power: 300 W to 9 MW |
Accuracy | Voltage: ±0.3% of reading ±0.1% full scale, Current: ±0.3% of reading ±0.1% full scale + clamp sensor, Active Power: ±0.3% of reading ±0.1% full scale + clamp sensor (at power factor = 1) |
Display Refresh Rate | 0.5 seconds |
Data Save | Destination: SD card, internal memory (at real time) Intervals: 1 to 30 seconds, 1 to 60 minutes, 14 selections |
Save Items | Measurement Value Save: Average only/average, max/min value, Screen Copy: BMP form (saved every 5 minutes at minimum interval time), Waveform Save: binary waveform data |
Interface | SD/SDHC memory card, 100Base-TX LAN, USB 2.0, Pulse output: proportional to active power consumption when measuring integral power consumption, isolated open-collector signal |
Functions | Connection check, quick set navigation guide, clock, pulse input |
Power Supply | 100 to 240 VAC 50/60 Hz 40 VA Z1006 AC adapter, 7.2 VDC 3 VA 9459 battery pack |
Dimensions | 1.89 x 7.09 x 3.94" (48 x 180 x 100 mm) |
Weight | 19.4 oz (550 g) |
Click on a category to view a selection of compatible accessories with the Hioki PW3360-20 Clamp-On Power Logger, 90 to 780 V.
Measurement | Line: 50/60 Hz Circuits: Single-phase 2-wire (1/2/3 circuits), single-phase 3-wire (1 circuit), 3-phase 3-wire (1 circuit), 3-phase 4 wires (1 circuit) |
Number of Channels | 1 to 3 (current only) |
Measurement Items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input |
Range | Voltage: 600 VAC (effective measurement range: 90 to 780 V) Current: 500 mA to 5 kA AC (depends on current sensor in use), 50 mA to 5 A AC (leak clamp on sensor only) Power: 300 W to 9 MW |
Accuracy | Voltage: ±0.3% of reading ±0.1% full scale, Current: ±0.3% of reading ±0.1% full scale + clamp sensor, Active Power: ±0.3% of reading ±0.1% full scale + clamp sensor (at power factor = 1) |
Display Refresh Rate | 0.5 seconds |
Data Save | Destination: SD card, internal memory (at real time) Intervals: 1 to 30 seconds, 1 to 60 minutes, 14 selections |
Save Items | Measurement Value Save: Average only/average, max/min value, Screen Copy: BMP form (saved every 5 minutes at minimum interval time), Waveform Save: binary waveform data |
Interface | SD/SDHC memory card, 100Base-TX LAN, USB 2.0, Pulse output: proportional to active power consumption when measuring integral power consumption, isolated open-collector signal |
Functions | Connection check, quick set navigation guide, clock, pulse input |
Power Supply | 100 to 240 VAC 50/60 Hz 40 VA Z1006 AC adapter, 7.2 VDC 3 VA 9459 battery pack |
Dimensions | 1.89 x 7.09 x 3.94" (48 x 180 x 100 mm) |
Weight | 19.4 oz (550 g) |
Click on a category to view a selection of compatible accessories with the Hioki PW3360-20 Clamp-On Power Logger, 90 to 780 V.