Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ

Model: IR5050

Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ

Model: IR5050

Ideal for high-voltage testing, this easy-to-use, compact, and lightweight insulation tester features stable measurement technology, noise rejection, and a GUARD terminal. Moreover, it has five measurement ranges and offers stable readings, intuitive rotary control, and advanced diagnostics with PI, DAR, and DD.

Ideal for high-voltage testing, this easy-to-use, compact, and lightweight insulation tester features stable measurement technology, noise rejection, and a GUARD terminal. Moreover, it has five measurement ranges and offers stable readings, intuitive rotary control, and advanced diagnostics with PI, DAR, and DD.

Your Price $2048.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your IR5050 High Voltage Insulation Tester

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your IR5050 High Voltage Insulation Tester

Hioki IR5050 Offers

The IR5050 is a compact, lightweight, high-voltage insulation resistance tester capable of outputting up to 5 kV. Its unique measurement technology enables stable measurements of up to 10 TΩ.

Features

  • Ideal for high-voltage insulation resistance testing: Best suited for high-voltage insulation resistance testing, the IR5050 is equipped with advanced measurement technology that guarantees stable readings across a range of applications, including high-voltage cables, transformers, and motors
  • Features an intuitive rotary knob for straightforward operation, enhancing its versatility and user-friendliness for diverse industrial uses
  • Advanced insulation diagnostic features: The IR5050 offers specialized insulation diagnostic functions such as step and ramp voltage testing. It automatically displays results in indices like PI (Polarization Index), DAR (Dielectric Absorption Ratio), and DD (Dielectric Discharge), streamlining the diagnostic process
  • Accurate, easy-to-use insulation resistance meter
  • Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
  • Wide testing voltage range, up to 5000 V from 250 V DC
  • Wide measurement insulation range, up to 10 TΩ
  • Automatically calculated and displayed insulation diagnostics (PI, DAR, and DD)
  • Data memory functions increase your work efficiency by eliminating human errors from manual reporting
  • Functions and performance for stable measurement: Shielded wire, GUARD terminal, filter function, inductive noise rejection function, minuscule current measurement technology
  • Selectable Interface Compatibility: Offers both wireless and USB connectivity options
  • Report function: Easily create PDF reports with measurement results
  • Excel® direct input function: Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®
  • Transfer data via USB after measurement: Transfer measured values and logging data saved on the instrument to a PC via USB,this function requires Sequence Maker, a free Excel add-in
  • Streamlined data management and reporting: Enhancing efficiency, the IR5050 comes with data memory, and options for wireless and USB connectivity
  • Facilitates real-time graph trending on mobile devices and enables quick report generation, simplifying data handling and documentation
  • Dustproof and waterproof case for outdoor work: The carrying case is a rigid case with IP65 dust and water protection. It provides space for the insulation resistance meter and test leads so that they can be transported easily
  • Compact and lightweight, equipped with an IP65-rated carrying case
  • Compatible with store-bought rechargeable batteries, which are both economical and environmentally friendly

Tailored measurement methods with advanced insulation diagnostic functions

When a high test voltage is continuously applied to the circuit under test, the insulation may break down. Failures caused by the application of a high voltage can be prevented by keeping the applied voltage as low as possible while testing the insulation. The IR5050 is equipped with various insulation diagnostic functions, allowing you to choose the optimal measurement method according to the testing application.

Automatically calculated and displayed insulation diagnostics

After measurement completes, the instrument can display more than just the insulation resistance and leakage current, but also judgement index values of PI, DD, and DAR. It calculates these indexes based on the measured values and displays it as a pass/fail judgment.

High-safety design insulation resistance meter

CAT III, CAT IV rated IR5050 hold the highest standards in safety performance. You may think that insulation resistance measurement is not dangerous because it is performed under power outage conditions, but on the contrary, accidents can be dangerous. The IR5050 have enhanced safety performance in case of such an accident.

Start test: Press and hold for 1 seconds to start measurement. This feature helps prevent inadvertent activation of a high voltage. To encourage caution, the MEASURE button flashes when a high voltage is being generated or discharged.

Complete: The IR5050 will start discharging automatically as soon as the test is over. During this time, the test start button will flash red to indicate that it is discharging.

Wireless (sold separately) and USB connectivity options for even greater convenience

  • Installing the Wireless Adapter Z3210 (sold separately) on the instrument enables Bluetooth® wireless communication, facilitating the transfer of measurements to your smartphone or tablet
  • Enhance your insulation resistance meter with GENNECT Cross
  • A time-series graph of the current provides a visualization of the insulation state of a high-voltage cable. Utilize the logging function of GENNECT Cross to generate time-series graphs of data recorded at one-second intervals, enhancing the analysis and understanding of trends
  • Field Maintenance function: Using a picture of the site, this function can display the measurement values where the measurements are made

Applications

  • High-voltage cable insulation testing
  • Transformer insulation diagnostics
  • Motor insulation measurement
  • Advanced insulation diagnostics
  • Data management and reporting
  • Outdoor testing

Hioki IR5050 Specifications

Basic Specifications (Input, Output, Measurement) Measurement items: Insulation resistance, leakage current, voltage, capacitance (DD function)
Maximum rated voltage to terminals: 1000 V AC, 2000 V DC
Maximum rated voltage to ground: 1000 V (CAT IV), 600 V (CAT III)
Insulation Resistance Measurement Test voltage: Constant voltage applied by the instrument to measure insulation resistance
Range of test voltage: 250 V to 5.20 kV DC
User-set test voltage: 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments
Open-circuit voltage: From 0% to 10% of test voltage
Rated current: 1 to 1.2 mA
Short-circuit current: 2 mA or less
Effect of capacitive components: Within ±10% error of measurement value when the DUT has a capacitance of 5 μF or less
Possible number of measurements: 200 times or more on one set of fully-charged batteries
Overload protection: 1100 V AC (10 sec., between +/- terminals); 6000 V DC (10 seconds, between +/- terminals)
Induced noise removal: 3 mA maximum

250 V
Guaranteed accuracy range: 0 MΩ to 2.5 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 2.51 GΩ to 500 GΩ
Accuracy: ±20% reading

500 V
Guaranteed accuracy range: 0 MΩ to 5 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 5.01 GΩ to 1 TΩ
Accuracy: ±20% reading

1000 V
Guaranteed accuracy range: 0 MΩ to 10 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 10.1 GΩ to 2 TΩ
Accuracy: ±20% reading

2500 V
Guaranteed accuracy range: 0 MΩ to 25 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 25.1 GΩ to 5 TΩ
Accuracy: ±20% reading

5000 V
Guaranteed accuracy range: 0 MΩ to 50 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 50.1 GΩ to 10 TΩ
Accuracy: ±20% reading
Leakage Current Measurement Accuracy: ±3% reading ±3 digit (guaranteed accuracy range: 1.00 nA to 3.00 mA)

Measurement Range: 10 nA
Display range: 0 to 9.99 nA
Resolution: 0.01 nA

Measurement range: 100 nA
Display range: 9 to 99.9 nA
Resolution: 0.1 nA

Measurement range: 1000 nA
Display range: 90 to 999 nA
Resolution: 1 nA

Measurement range: 10 μA
Display range: 0.90 to 9.99 μA
Resolution: 0.01 μA

Measurement range: 100 μA
Display range: 9 to 99.9 μA
Resolution: 0.1 μA

Measurement range: 1 mA
Display range: 90 to 999 μA
Resolution: 1 μA
Display Range: 0.90 to 3 mA
Resolution: 0.01 mA
Voltage Measurement Guaranteed accuracy range: 30 V to 1000 V AC (45 Hz to 65 Hz), ±10 V to ±2000 V DC
Accuracy: ±3% reading ±3 digit
Input resistance: 500 kΩ or more (DC, 45 to 65 Hz)
Overload protection: 1100 V AC (1 minute, between +/- terminals), 2200 V DC (1 minute, between +/- terminals)
Capacitance Measurement Capacitance is automatically measured after insulation resistance measurement is over (not measured if output voltage is 250 V or less)

Accuracy: ±10% reading ±5 nF (guaranteed accuracy range: 10.0 nF to 25.0 μF)
Measurement range: 100 nF
Display range: 0.0 nF to 99.9 nF
Resolution: 0.1 nF

Measurement range: 1000 nF
Display range: 100 nF to 999 nF
Resolution: 1 nF

Measurement range: 10 μF
Display range: 1.00 μF to 9.99 μF
Resolution: 0.01 μF
Display range: 10.0 μF to 25.0 μF
Resolution: 0.1 μF
Functions Insulation diagnosis: PI, DAR, DD, SV, Ramp, Timer 2
Others Battery charge indicator, live circuit indicator, automatic power save, automatic discharge, backlight, buzzer, manual recording, logging recording, temperature and humidity input, elapsed time display, clock, filter, hardware filter, data-hold, system reset, USB communication (only when DT4900-01 (sold separately) is installed), wireless communication (only when Z3210 (sold separately) is installed), comparator, resistance gauge display, switching of insulation diagnosis function, breakdown cut-off
Environmental Conditions Operating environment indoors: up to 6562.20' (2000 m)

Operating temperature and humidity range: -4 to 104°F (-20 to 40°C), less than 80% RH (no condensation)
104 to 113°F (40 to 45°C), less than 60% RH (no condensation)
113 to 122°F (45 to 50°C), less than 50% RH (no condensation)

Storage temperature and humidity range: -13 to 149°F (-25 to 65°C), less than 80% RH (no condensation)
Dustproof/waterproof IP40 (with protector attached, excluding terminals)
IP65 (Carrying case C0212)
Standards Safety: EN IEC 61010-2-034: 2021, EN IEC 61010-2-033: 2021
Electromagnetic Compatibility (EMC): EN 61326
Insulation Resistance Tester: IEC 61557-1, IEC 61557-2
Power Supply 8 x AA alkaline battery
8 x HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery
Maximum power consumption: 12 VA
Continuous operating time, reference value at 73°F (23°C)
Approximately 5 hours without Z3210 (sold separately) installed; approximately 4 hours with Z3210 (sold separately) installed and using wireless communication
Conditions: when using alkaline batteries, 5 kV generated, +/- terminals open, backlight off, and comparator off
Dimensions 7.68 × 10 × 3.50" (195 × 254 × 89 mm)
Weight With batteries: 59.97 oz. (1.7 kg)
Click here for complete specifications on the Hioki IR5050

What's included with the Hioki IR5050

  • Insulation Tester
  • 9.84' (3 m) Red Test Lead
  • 9.84' (3 m) Black Test Lead
  • 9.84' (3 m) Blue Test Lead
  • Red Alligator Clip
  • Black Alligator Clip
  • Blue Alligator Clip
  • Carrying Case
  • 8 x LR6 (AA) Alkaline Battery
  • Instruction Manual
  • Operating Precautions

Click on a category to view a selection of compatible accessories with the Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ.

Hioki DT4900-01 Communication Package, USB DT4900-01
Use this communication package to connect your compatible Hioki model to your PC. The package features USB connectivity for simple setup.




Hioki Z3210 Wireless Adapter for the FT6031-50/FT6380-50/CM4002/IR4057-50/PD3259-50/BT3554-50/CM4003/CM4001 Z3210
Offers a Bluetooth wireless adapter, this wireless adapter creates and shares graphical reports and works with earth testers, clamp meters, insulation tester, phase detector, and battery tester. In addition, it has an operating temperature of -22 to 158°F (-30 to 70°C).




Ask a question about Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ

Customer Reviews for the Hioki IR5050

Hioki IR5050 Offers

The IR5050 is a compact, lightweight, high-voltage insulation resistance tester capable of outputting up to 5 kV. Its unique measurement technology enables stable measurements of up to 10 TΩ.

Features

  • Ideal for high-voltage insulation resistance testing: Best suited for high-voltage insulation resistance testing, the IR5050 is equipped with advanced measurement technology that guarantees stable readings across a range of applications, including high-voltage cables, transformers, and motors
  • Features an intuitive rotary knob for straightforward operation, enhancing its versatility and user-friendliness for diverse industrial uses
  • Advanced insulation diagnostic features: The IR5050 offers specialized insulation diagnostic functions such as step and ramp voltage testing. It automatically displays results in indices like PI (Polarization Index), DAR (Dielectric Absorption Ratio), and DD (Dielectric Discharge), streamlining the diagnostic process
  • Accurate, easy-to-use insulation resistance meter
  • Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
  • Wide testing voltage range, up to 5000 V from 250 V DC
  • Wide measurement insulation range, up to 10 TΩ
  • Automatically calculated and displayed insulation diagnostics (PI, DAR, and DD)
  • Data memory functions increase your work efficiency by eliminating human errors from manual reporting
  • Functions and performance for stable measurement: Shielded wire, GUARD terminal, filter function, inductive noise rejection function, minuscule current measurement technology
  • Selectable Interface Compatibility: Offers both wireless and USB connectivity options
  • Report function: Easily create PDF reports with measurement results
  • Excel® direct input function: Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®
  • Transfer data via USB after measurement: Transfer measured values and logging data saved on the instrument to a PC via USB,this function requires Sequence Maker, a free Excel add-in
  • Streamlined data management and reporting: Enhancing efficiency, the IR5050 comes with data memory, and options for wireless and USB connectivity
  • Facilitates real-time graph trending on mobile devices and enables quick report generation, simplifying data handling and documentation
  • Dustproof and waterproof case for outdoor work: The carrying case is a rigid case with IP65 dust and water protection. It provides space for the insulation resistance meter and test leads so that they can be transported easily
  • Compact and lightweight, equipped with an IP65-rated carrying case
  • Compatible with store-bought rechargeable batteries, which are both economical and environmentally friendly

Tailored measurement methods with advanced insulation diagnostic functions

When a high test voltage is continuously applied to the circuit under test, the insulation may break down. Failures caused by the application of a high voltage can be prevented by keeping the applied voltage as low as possible while testing the insulation. The IR5050 is equipped with various insulation diagnostic functions, allowing you to choose the optimal measurement method according to the testing application.

Automatically calculated and displayed insulation diagnostics

After measurement completes, the instrument can display more than just the insulation resistance and leakage current, but also judgement index values of PI, DD, and DAR. It calculates these indexes based on the measured values and displays it as a pass/fail judgment.

High-safety design insulation resistance meter

CAT III, CAT IV rated IR5050 hold the highest standards in safety performance. You may think that insulation resistance measurement is not dangerous because it is performed under power outage conditions, but on the contrary, accidents can be dangerous. The IR5050 have enhanced safety performance in case of such an accident.

Start test: Press and hold for 1 seconds to start measurement. This feature helps prevent inadvertent activation of a high voltage. To encourage caution, the MEASURE button flashes when a high voltage is being generated or discharged.

Complete: The IR5050 will start discharging automatically as soon as the test is over. During this time, the test start button will flash red to indicate that it is discharging.

Wireless (sold separately) and USB connectivity options for even greater convenience

  • Installing the Wireless Adapter Z3210 (sold separately) on the instrument enables Bluetooth® wireless communication, facilitating the transfer of measurements to your smartphone or tablet
  • Enhance your insulation resistance meter with GENNECT Cross
  • A time-series graph of the current provides a visualization of the insulation state of a high-voltage cable. Utilize the logging function of GENNECT Cross to generate time-series graphs of data recorded at one-second intervals, enhancing the analysis and understanding of trends
  • Field Maintenance function: Using a picture of the site, this function can display the measurement values where the measurements are made

Applications

  • High-voltage cable insulation testing
  • Transformer insulation diagnostics
  • Motor insulation measurement
  • Advanced insulation diagnostics
  • Data management and reporting
  • Outdoor testing

Hioki IR5050 Specifications

Basic Specifications (Input, Output, Measurement) Measurement items: Insulation resistance, leakage current, voltage, capacitance (DD function)
Maximum rated voltage to terminals: 1000 V AC, 2000 V DC
Maximum rated voltage to ground: 1000 V (CAT IV), 600 V (CAT III)
Insulation Resistance Measurement Test voltage: Constant voltage applied by the instrument to measure insulation resistance
Range of test voltage: 250 V to 5.20 kV DC
User-set test voltage: 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments
Open-circuit voltage: From 0% to 10% of test voltage
Rated current: 1 to 1.2 mA
Short-circuit current: 2 mA or less
Effect of capacitive components: Within ±10% error of measurement value when the DUT has a capacitance of 5 μF or less
Possible number of measurements: 200 times or more on one set of fully-charged batteries
Overload protection: 1100 V AC (10 sec., between +/- terminals); 6000 V DC (10 seconds, between +/- terminals)
Induced noise removal: 3 mA maximum

250 V
Guaranteed accuracy range: 0 MΩ to 2.5 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 2.51 GΩ to 500 GΩ
Accuracy: ±20% reading

500 V
Guaranteed accuracy range: 0 MΩ to 5 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 5.01 GΩ to 1 TΩ
Accuracy: ±20% reading

1000 V
Guaranteed accuracy range: 0 MΩ to 10 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 10.1 GΩ to 2 TΩ
Accuracy: ±20% reading

2500 V
Guaranteed accuracy range: 0 MΩ to 25 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 25.1 GΩ to 5 TΩ
Accuracy: ±20% reading

5000 V
Guaranteed accuracy range: 0 MΩ to 50 GΩ
Accuracy: ±5% reading ±5 digit
Guaranteed accuracy range: 50.1 GΩ to 10 TΩ
Accuracy: ±20% reading
Leakage Current Measurement Accuracy: ±3% reading ±3 digit (guaranteed accuracy range: 1.00 nA to 3.00 mA)

Measurement Range: 10 nA
Display range: 0 to 9.99 nA
Resolution: 0.01 nA

Measurement range: 100 nA
Display range: 9 to 99.9 nA
Resolution: 0.1 nA

Measurement range: 1000 nA
Display range: 90 to 999 nA
Resolution: 1 nA

Measurement range: 10 μA
Display range: 0.90 to 9.99 μA
Resolution: 0.01 μA

Measurement range: 100 μA
Display range: 9 to 99.9 μA
Resolution: 0.1 μA

Measurement range: 1 mA
Display range: 90 to 999 μA
Resolution: 1 μA
Display Range: 0.90 to 3 mA
Resolution: 0.01 mA
Voltage Measurement Guaranteed accuracy range: 30 V to 1000 V AC (45 Hz to 65 Hz), ±10 V to ±2000 V DC
Accuracy: ±3% reading ±3 digit
Input resistance: 500 kΩ or more (DC, 45 to 65 Hz)
Overload protection: 1100 V AC (1 minute, between +/- terminals), 2200 V DC (1 minute, between +/- terminals)
Capacitance Measurement Capacitance is automatically measured after insulation resistance measurement is over (not measured if output voltage is 250 V or less)

Accuracy: ±10% reading ±5 nF (guaranteed accuracy range: 10.0 nF to 25.0 μF)
Measurement range: 100 nF
Display range: 0.0 nF to 99.9 nF
Resolution: 0.1 nF

Measurement range: 1000 nF
Display range: 100 nF to 999 nF
Resolution: 1 nF

Measurement range: 10 μF
Display range: 1.00 μF to 9.99 μF
Resolution: 0.01 μF
Display range: 10.0 μF to 25.0 μF
Resolution: 0.1 μF
Functions Insulation diagnosis: PI, DAR, DD, SV, Ramp, Timer 2
Others Battery charge indicator, live circuit indicator, automatic power save, automatic discharge, backlight, buzzer, manual recording, logging recording, temperature and humidity input, elapsed time display, clock, filter, hardware filter, data-hold, system reset, USB communication (only when DT4900-01 (sold separately) is installed), wireless communication (only when Z3210 (sold separately) is installed), comparator, resistance gauge display, switching of insulation diagnosis function, breakdown cut-off
Environmental Conditions Operating environment indoors: up to 6562.20' (2000 m)

Operating temperature and humidity range: -4 to 104°F (-20 to 40°C), less than 80% RH (no condensation)
104 to 113°F (40 to 45°C), less than 60% RH (no condensation)
113 to 122°F (45 to 50°C), less than 50% RH (no condensation)

Storage temperature and humidity range: -13 to 149°F (-25 to 65°C), less than 80% RH (no condensation)
Dustproof/waterproof IP40 (with protector attached, excluding terminals)
IP65 (Carrying case C0212)
Standards Safety: EN IEC 61010-2-034: 2021, EN IEC 61010-2-033: 2021
Electromagnetic Compatibility (EMC): EN 61326
Insulation Resistance Tester: IEC 61557-1, IEC 61557-2
Power Supply 8 x AA alkaline battery
8 x HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery
Maximum power consumption: 12 VA
Continuous operating time, reference value at 73°F (23°C)
Approximately 5 hours without Z3210 (sold separately) installed; approximately 4 hours with Z3210 (sold separately) installed and using wireless communication
Conditions: when using alkaline batteries, 5 kV generated, +/- terminals open, backlight off, and comparator off
Dimensions 7.68 × 10 × 3.50" (195 × 254 × 89 mm)
Weight With batteries: 59.97 oz. (1.7 kg)
Click here for complete specifications on the Hioki IR5050

What's included with the Hioki IR5050

  • Insulation Tester
  • 9.84' (3 m) Red Test Lead
  • 9.84' (3 m) Black Test Lead
  • 9.84' (3 m) Blue Test Lead
  • Red Alligator Clip
  • Black Alligator Clip
  • Blue Alligator Clip
  • Carrying Case
  • 8 x LR6 (AA) Alkaline Battery
  • Instruction Manual
  • Operating Precautions

Click on a category to view a selection of compatible accessories with the Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ.

Hioki DT4900-01 Communication Package, USB DT4900-01
Use this communication package to connect your compatible Hioki model to your PC. The package features USB connectivity for simple setup.




Hioki Z3210 Wireless Adapter for the FT6031-50/FT6380-50/CM4002/IR4057-50/PD3259-50/BT3554-50/CM4003/CM4001 Z3210
Offers a Bluetooth wireless adapter, this wireless adapter creates and shares graphical reports and works with earth testers, clamp meters, insulation tester, phase detector, and battery tester. In addition, it has an operating temperature of -22 to 158°F (-30 to 70°C).




Ask a question about Hioki IR5050 High Voltage Insulation Tester, 5 kV, 10 TΩ

Customer Reviews for the Hioki IR5050

More Hioki Products

Calibration Lab