The earth ground resistance tester measures grounding resistance by clamping to multiple grounded wires. It clamps ground wires with ease and provides AC measurement functionalities. It also measures currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
The earth ground resistance tester measures grounding resistance by clamping to multiple grounded wires. It clamps ground wires with ease and provides AC measurement functionalities. It also measures currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
| Display | Digital/LCD, maximum 2000 digits Display update rate: 2 times per seconds |
| Maximum Conductor Diameter for Measurement | Φ32 mm |
| Power Supply | LR6 alkaline battery × 2 |
| Continuous Operating Time | 20 hours With display lighting off, Bluetooth OFF (FT6381) |
| Auto Power Save | Power save state when 5 minutes have elapsed since the last operation |
| Operating Temperature and Humidity | 14 to 122°F (-10 to 50°C) 80% rh or less (no condensation) |
| Storage Temperature (No Condensation) | -10 to 50°C (14 to 122°F) 80% rh or less |
| Dust Proof and Waterproof | IP40 (EN60529) With Jaw Closed |
| Temperature Characteristics | In 14 to 122°F (-10 to 50°C) range: add 0.1 × Measurement accuracy /°C |
| Withstand Voltage | AC7400 Vrms for one minute between clamp sensor and casing |
| Applicable Standards | Safety: EN61010 EMC: EN61326 |
| Dimensions | 2.87 ×8.58 ×1.73" (73 × 218 × 44 mm) |
| Weight | 22.9 oz (650 g) |
| Display | Digital/LCD, maximum 2000 digits Display update rate: 2 times per seconds |
| Maximum Conductor Diameter for Measurement | Φ32 mm |
| Power Supply | LR6 alkaline battery × 2 |
| Continuous Operating Time | 20 hours With display lighting off, Bluetooth OFF (FT6381) |
| Auto Power Save | Power save state when 5 minutes have elapsed since the last operation |
| Operating Temperature and Humidity | 14 to 122°F (-10 to 50°C) 80% rh or less (no condensation) |
| Storage Temperature (No Condensation) | -10 to 50°C (14 to 122°F) 80% rh or less |
| Dust Proof and Waterproof | IP40 (EN60529) With Jaw Closed |
| Temperature Characteristics | In 14 to 122°F (-10 to 50°C) range: add 0.1 × Measurement accuracy /°C |
| Withstand Voltage | AC7400 Vrms for one minute between clamp sensor and casing |
| Applicable Standards | Safety: EN61010 EMC: EN61326 |
| Dimensions | 2.87 ×8.58 ×1.73" (73 × 218 × 44 mm) |
| Weight | 22.9 oz (650 g) |