The clamp on earth tester measures grounding resistance by clamping to multiple grounded ground wires. It also provides AC current measurement and can measure currents ranging from leakage current of several mA to load currents of up to 60 A.
The clamp on earth tester measures grounding resistance by clamping to multiple grounded ground wires. It also provides AC current measurement and can measure currents ranging from leakage current of several mA to load currents of up to 60 A.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Get things done with this super slim jaw clamp on meter from Hioki.
| Measurement Principle | Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value. |
| Earthing Resistance Range | 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω, Accuracy: ±1.5% rdg. ±0.02 Ω |
| AC Current Range | 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA, Accuracy: ±2.0% rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less) |
| Maximum Allowable Input | 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50/60 Hz, requires derating at frequency) |
| Maximum Rated Voltage to Earth | 600 V AC CAT IV |
| Memory Function | 2000 data |
| Alarm Function | For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold |
| Display | Digital LCD, maximum 2000 dgt., Display refresh rate: 500 ms (2 times/s) |
| Waterproof and Dustproof | IP40 (EN60529) with clamp sensor closed |
| Power Supply | LR6 (AA) alkaline battery ×2, maximum rated power: 450 mVA, Continuous use : 35 hr (in-house testing conditions) |
| Core Jaw Diameter | Φ 1.26" (32 mm) |
| Dimensions | 2.87 x 8.58 x 1.69" (73 x 218 x 43 mm) |
| Weight | 21.9 oz (620 g) |
| Measurement Principle | Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value. |
| Earthing Resistance Range | 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω, Accuracy: ±1.5% rdg. ±0.02 Ω |
| AC Current Range | 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA, Accuracy: ±2.0% rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less) |
| Maximum Allowable Input | 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50/60 Hz, requires derating at frequency) |
| Maximum Rated Voltage to Earth | 600 V AC CAT IV |
| Memory Function | 2000 data |
| Alarm Function | For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold |
| Display | Digital LCD, maximum 2000 dgt., Display refresh rate: 500 ms (2 times/s) |
| Waterproof and Dustproof | IP40 (EN60529) with clamp sensor closed |
| Power Supply | LR6 (AA) alkaline battery ×2, maximum rated power: 450 mVA, Continuous use : 35 hr (in-house testing conditions) |
| Core Jaw Diameter | Φ 1.26" (32 mm) |
| Dimensions | 2.87 x 8.58 x 1.69" (73 x 218 x 43 mm) |