Hioki DT4281 Digital Multimeter

Model: DT4281

Hioki DT4281 Digital Multimeter

Model: DT4281

World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.

World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.

Sale Price $507.30 USD
Regular Price $534.00 USD
Availability 4 to 5 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your DT4281 Digital Multimeter

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your DT4281 Digital Multimeter

Hioki DT4281 Offers

The Hioki DT4281 Digital Multimeter gives you high accuracy and fast response time and improves efficiency with useful functions suitable for professional testing such as new energy development and facility maintenance.

In maintenance inspections of electrical equipment in buildings and manufacturing plants, and research and development as well as maintenance inspections of equipment such as inverters and solar power systems, the ability to make high-precision measurements without compromising work efficiency is essential. The HIOKI Digital Multimeters DT4281 and DT4282 were developed to help professionals do their jobs quickly by enabling efficient, high-precision measurement.

Both instruments feature reduced measurement times, allowing them to deliver the fastest response speed of any portable multimeter. As reflected by safety performance that allows use in applications up to CAT IV (600V), the most demanding measurement category, and a broad operating temperature range, they are also inherently safe products that can be used with confidence and peace of mind. Furthermore, with basic accuracy of ±0.025% for DC voltage measurement and an AC voltage frequency band of 20 to 100 kHz, the new DMMs deliver the highest accuracy and broadest frequency band of any portable multimeter.

Features

  • 60,000 count, 5-digit display, high-resolution measurements
  • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
  • Terminal shutter mechanism (prevents erroneous test lead insertion)
  • Dual display lets you check voltage and frequency simultaneously

Voltage, Current and Input Safety 

The instrument measures DC, AC and AC+DC voltage up to 1000 V and meets CAT III 1000 V and CAT IV 600 V safety ratings. For direct AC/DC current measurement, it provides the ranges 600 μA, 6 mA, 60 mA and 600 mA, while compatible HIOKI current sensors extend AC current measurement from 10 A to 1000 A. Terminal shutters linked to the rotary switch block unused input terminals and help prevent incorrect test lead insertion. 

During AC voltage and AC current measurement, the instrument displays frequency simultaneously as a secondary reading. The frequency measurement range extends from 99.999 Hz to 500.00 kHz with an accuracy of ±0.005% of reading + 3 digits. Additional measurement functions include resistance, continuity, diode test, capacitance and temperature measurement with a K thermocouple such as the optional DT4910. 

Current Measurement with Current Sensors 

For AC current measurement beyond the direct input range, the DT4281 supports compatible HIOKI current sensors. The sensors are connected via the 9704 BNC adapter. When the current range selected on the instrument matches the range selected on the connected sensor, the measured value is displayed directly as a current value on the instrument. Manual conversion of the sensor output signal is not required. 

With the compatible 9010-50, 9018-50 and 9132-50 current sensors, the instrument covers AC current measurement from 10 A to 1000 A. The 9010-50 and 9018-50 support ranges up to 500 A, while the 9132-50 extends the range up to 1000 A. For applications up to 500 A, the 9010-50 covers current measurement up to 1 kHz, while the 9018-50 extends the frequency range up to 3 kHz and provides higher amplitude and phase accuracy. 

For Service, Maintenance and Process Signals 

The DT4281 covers AC voltage measurements from 20 Hz to 100 kHz. In addition, the analog low pass filter with a 630 Hz cut off suppresses higher frequency components so that the fundamental waveform can be evaluated more clearly. For service and maintenance tasks, the instrument also provides MAX/MIN and peak value measurement as well as HOLD and AUTO HOLD functions. The relative display function shows subsequent readings relative to a reference value, and zero adjustment compensates offsets before measurement, for example when low resistance values are evaluated. Excessively high input is indicated by the red screen backlight and a buzzer.

For process related measurements, 4 to 20 mA and 0 to 20 mA signals can be displayed directly as percentage values from 0 to 100%, which is useful for checking transmitter and process signals without manual conversion from mA values. Measured values can be stored in the internal memory with up to 400 data points and transferred to a PC with the optional DT4900-01 Communication Package. 

For Everyday Use in Service and in the Field 

The DT4281 is built for everyday use in service, maintenance and commissioning, with an operating temperature range from -15 °C to 55 °C, drop resistance from a height of 1 m and a continuous operating time of approximately 100 hours with four AA alkaline batteries. The rear kickstand supports setup at the measurement location, while the test leads can be stored directly on the back of the instrument. The supplied L9300 test lead uses a movable finger guard instead of separate protective caps. This allows adaptation of the exposed metal tip length to the relevant measurement category without loose accessories that can be misplaced during daily work. 

For mounting at the measurement location, the DT4281 can be combined with optional magnetic straps. The Z5004 is sufficient for typical attachment to magnetic steel surfaces such as distribution cabinets. Where additional cable weight is present, especially with connected current clamps, the stronger Z5020 provides a higher holding force and greater stability if the instrument or connected leads are bumped or shifted during work.

Applications

  • Detecting voltage
  • Electrical contractors
  • HVAC/R technicians
  • Plant maintenance

Hioki DT4281 Specifications

DC Voltage
Range 60 mV to 1000 V
Accuracy 60 mV: ±0.2% rdg. ±25 dgt.
600 mV: ±0.025% rdg. ±5 dgt.
6 V: ±0.025% rdg. ±2 dgt.
60 V: ±0.025% rdg. ±2 dgt.
600 V: ±0.03% rdg. ±2 dgt.
1000 V: ±0.03% rdg. ±2 dgt.
Input Impedance 60 mV: 1 GΩ or more: 100 pF or less
600 mV: 1 GΩ or more: 100 pF or less
6 V: 11 MΩ ±2% : 100 pF or less
60 V: 10.3 MΩ ±2% : 100 pF or less
600 V: 10.2 MΩ ±2% : 100 pF or less
1000 V: 10.2 MΩ ±2% : 100 pF or less
DCA Measurement
Range 600 μA to 600 mA
Accuracy 600 μA: ±0.05% rdg. ±25 dgt.
6000 μA: ±0.05% rdg. ±5 dgt.
60 mA: ±0.05% rdg. ±25 dgt.
600 mA: ±0.15% rdg. ±5 dgt.
Shunt Resistance 600 to 6000 μA: 101 Ω
60 to 600 mA: 1 Ω
Resistance Measurement
Range 60 Ω to 600 mΩ
Accuracy 60 Ω: ±0.3% rdg. ±20 dgt.
600 Ω: ±0.03% rdg. ±10 dgt.
6 to 60 kΩ: ±0.03% rdg. ±2 dgt.
600 kΩ: ±0.03% rdg. ±2 dgt.
6 MΩ: ±0.15% rdg. ±4 dgt.
60 MΩ: ±1.5% rdg. ±10 dgt.
600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt.
Measurement Current 60 to 600 Ω: 640 μA ±10%
6 kΩ: 96 μA ±10%
60 kΩ: 9.3 μA ±10%
600 kΩ: 0.96 μA ±10%
6 to 600 MΩ: 96 nA ±10%
Open-Terminal Voltage 2.5V DC or less
Continuity Check
Range 600.0 Ω
Accuracy ±0.5% rdg. ±5 dgt.
Measurement Current 640 μA ±10%
Open-Terminal Voltage 2.5 V DC or less
Electrostatic Capacity
Range 1 nF to 100 mF
Accuracy 1 nF: ±1.0% rdg. ±20 dgt.
10 nF to 1 μF: ±1.0% rdg. ±5 dgt.
10 μF to 10 mF: ±2.0% rdg. ±5 dgt.
100 mF: ±2.0% rdg. ±20 dgt
Measurement Current 1 nF to 1 μF: 32 μA ±10%
10 μF to 100 mF: 680 μA ±10%
Open-Circuit Voltage 1 nF to 1 μF: DC2.5 V or less
10 to 100 μF: DC3.1 V or less
1 to 100 mF: DC2.1 V or less
Click here for complete specifications on the Hioki DT4281

What's included with the Hioki DT4281

  • Digital Multimeter
  • Test Lead
  • 4 x LR6 Batteries
  • Manual

Ask a question about Hioki DT4281 Digital Multimeter

Customer Reviews for the Hioki DT4281

Hioki DT4281 Offers

The Hioki DT4281 Digital Multimeter gives you high accuracy and fast response time and improves efficiency with useful functions suitable for professional testing such as new energy development and facility maintenance.

In maintenance inspections of electrical equipment in buildings and manufacturing plants, and research and development as well as maintenance inspections of equipment such as inverters and solar power systems, the ability to make high-precision measurements without compromising work efficiency is essential. The HIOKI Digital Multimeters DT4281 and DT4282 were developed to help professionals do their jobs quickly by enabling efficient, high-precision measurement.

Both instruments feature reduced measurement times, allowing them to deliver the fastest response speed of any portable multimeter. As reflected by safety performance that allows use in applications up to CAT IV (600V), the most demanding measurement category, and a broad operating temperature range, they are also inherently safe products that can be used with confidence and peace of mind. Furthermore, with basic accuracy of ±0.025% for DC voltage measurement and an AC voltage frequency band of 20 to 100 kHz, the new DMMs deliver the highest accuracy and broadest frequency band of any portable multimeter.

Features

  • 60,000 count, 5-digit display, high-resolution measurements
  • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
  • Terminal shutter mechanism (prevents erroneous test lead insertion)
  • Dual display lets you check voltage and frequency simultaneously

Voltage, Current and Input Safety 

The instrument measures DC, AC and AC+DC voltage up to 1000 V and meets CAT III 1000 V and CAT IV 600 V safety ratings. For direct AC/DC current measurement, it provides the ranges 600 μA, 6 mA, 60 mA and 600 mA, while compatible HIOKI current sensors extend AC current measurement from 10 A to 1000 A. Terminal shutters linked to the rotary switch block unused input terminals and help prevent incorrect test lead insertion. 

During AC voltage and AC current measurement, the instrument displays frequency simultaneously as a secondary reading. The frequency measurement range extends from 99.999 Hz to 500.00 kHz with an accuracy of ±0.005% of reading + 3 digits. Additional measurement functions include resistance, continuity, diode test, capacitance and temperature measurement with a K thermocouple such as the optional DT4910. 

Current Measurement with Current Sensors 

For AC current measurement beyond the direct input range, the DT4281 supports compatible HIOKI current sensors. The sensors are connected via the 9704 BNC adapter. When the current range selected on the instrument matches the range selected on the connected sensor, the measured value is displayed directly as a current value on the instrument. Manual conversion of the sensor output signal is not required. 

With the compatible 9010-50, 9018-50 and 9132-50 current sensors, the instrument covers AC current measurement from 10 A to 1000 A. The 9010-50 and 9018-50 support ranges up to 500 A, while the 9132-50 extends the range up to 1000 A. For applications up to 500 A, the 9010-50 covers current measurement up to 1 kHz, while the 9018-50 extends the frequency range up to 3 kHz and provides higher amplitude and phase accuracy. 

For Service, Maintenance and Process Signals 

The DT4281 covers AC voltage measurements from 20 Hz to 100 kHz. In addition, the analog low pass filter with a 630 Hz cut off suppresses higher frequency components so that the fundamental waveform can be evaluated more clearly. For service and maintenance tasks, the instrument also provides MAX/MIN and peak value measurement as well as HOLD and AUTO HOLD functions. The relative display function shows subsequent readings relative to a reference value, and zero adjustment compensates offsets before measurement, for example when low resistance values are evaluated. Excessively high input is indicated by the red screen backlight and a buzzer.

For process related measurements, 4 to 20 mA and 0 to 20 mA signals can be displayed directly as percentage values from 0 to 100%, which is useful for checking transmitter and process signals without manual conversion from mA values. Measured values can be stored in the internal memory with up to 400 data points and transferred to a PC with the optional DT4900-01 Communication Package. 

For Everyday Use in Service and in the Field 

The DT4281 is built for everyday use in service, maintenance and commissioning, with an operating temperature range from -15 °C to 55 °C, drop resistance from a height of 1 m and a continuous operating time of approximately 100 hours with four AA alkaline batteries. The rear kickstand supports setup at the measurement location, while the test leads can be stored directly on the back of the instrument. The supplied L9300 test lead uses a movable finger guard instead of separate protective caps. This allows adaptation of the exposed metal tip length to the relevant measurement category without loose accessories that can be misplaced during daily work. 

For mounting at the measurement location, the DT4281 can be combined with optional magnetic straps. The Z5004 is sufficient for typical attachment to magnetic steel surfaces such as distribution cabinets. Where additional cable weight is present, especially with connected current clamps, the stronger Z5020 provides a higher holding force and greater stability if the instrument or connected leads are bumped or shifted during work.

Applications

  • Detecting voltage
  • Electrical contractors
  • HVAC/R technicians
  • Plant maintenance

Hioki DT4281 Specifications

DC Voltage
Range 60 mV to 1000 V
Accuracy 60 mV: ±0.2% rdg. ±25 dgt.
600 mV: ±0.025% rdg. ±5 dgt.
6 V: ±0.025% rdg. ±2 dgt.
60 V: ±0.025% rdg. ±2 dgt.
600 V: ±0.03% rdg. ±2 dgt.
1000 V: ±0.03% rdg. ±2 dgt.
Input Impedance 60 mV: 1 GΩ or more: 100 pF or less
600 mV: 1 GΩ or more: 100 pF or less
6 V: 11 MΩ ±2% : 100 pF or less
60 V: 10.3 MΩ ±2% : 100 pF or less
600 V: 10.2 MΩ ±2% : 100 pF or less
1000 V: 10.2 MΩ ±2% : 100 pF or less
DCA Measurement
Range 600 μA to 600 mA
Accuracy 600 μA: ±0.05% rdg. ±25 dgt.
6000 μA: ±0.05% rdg. ±5 dgt.
60 mA: ±0.05% rdg. ±25 dgt.
600 mA: ±0.15% rdg. ±5 dgt.
Shunt Resistance 600 to 6000 μA: 101 Ω
60 to 600 mA: 1 Ω
Resistance Measurement
Range 60 Ω to 600 mΩ
Accuracy 60 Ω: ±0.3% rdg. ±20 dgt.
600 Ω: ±0.03% rdg. ±10 dgt.
6 to 60 kΩ: ±0.03% rdg. ±2 dgt.
600 kΩ: ±0.03% rdg. ±2 dgt.
6 MΩ: ±0.15% rdg. ±4 dgt.
60 MΩ: ±1.5% rdg. ±10 dgt.
600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt.
Measurement Current 60 to 600 Ω: 640 μA ±10%
6 kΩ: 96 μA ±10%
60 kΩ: 9.3 μA ±10%
600 kΩ: 0.96 μA ±10%
6 to 600 MΩ: 96 nA ±10%
Open-Terminal Voltage 2.5V DC or less
Continuity Check
Range 600.0 Ω
Accuracy ±0.5% rdg. ±5 dgt.
Measurement Current 640 μA ±10%
Open-Terminal Voltage 2.5 V DC or less
Electrostatic Capacity
Range 1 nF to 100 mF
Accuracy 1 nF: ±1.0% rdg. ±20 dgt.
10 nF to 1 μF: ±1.0% rdg. ±5 dgt.
10 μF to 10 mF: ±2.0% rdg. ±5 dgt.
100 mF: ±2.0% rdg. ±20 dgt
Measurement Current 1 nF to 1 μF: 32 μA ±10%
10 μF to 100 mF: 680 μA ±10%
Open-Circuit Voltage 1 nF to 1 μF: DC2.5 V or less
10 to 100 μF: DC3.1 V or less
1 to 100 mF: DC2.1 V or less
Click here for complete specifications on the Hioki DT4281

What's included with the Hioki DT4281

  • Digital Multimeter
  • Test Lead
  • 4 x LR6 Batteries
  • Manual

Ask a question about Hioki DT4281 Digital Multimeter

Customer Reviews for the Hioki DT4281

More Hioki Products