A Standard for quality testing of lithium-ion batteries, the battery hi-tester features high-precision measurement capabilities. Augmented with improved tolerances for path resistance to keep measurement errors from halting automatic testing lines and significantly improved resistance to static electricity.
A Standard for quality testing of lithium-ion batteries, the battery hi-tester features high-precision measurement capabilities. Augmented with improved tolerances for path resistance to keep measurement errors from halting automatic testing lines and significantly improved resistance to static electricity.
Fully automated production line testing of large cells for xEVs or mid-sized packs of up to 100 V.
Applications
Resistance Measurement Ranges | 3 mΩ maximum display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA 30 mΩ maximum display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA 300 mΩ maximum display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA 3 Ω maximum display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA 30 Ω maximum display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA 300 Ω maximum display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA 3 kΩ maximum display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA |
Basic Accuracy | ±0.5% rdg ±10 dgt (3 mΩ range), ±0.5% rdg ±5 dgt (30 mΩ range or more) |
Measurement Frequency | 1 kHz ±0.2 Hz |
Measurement Method | AC four-terminal method |
Voltage Measurement Ranges | 6 V (maximum display: 6.00000 V, resolution: 10 μV) 60 V (maximum display: 60.0000 V, resolution: 100 μV) 100 V (maximum display: 100.000 V, resolution: 1 mV) |
Response Time | 10 ms |
Functions | Contact check, zero adjustment (±1000 counts), pulse measurement, comparator (Hi/ IN/ Lo), statistical calculations (maximum 30,000), delay, average, panel saving/loading, memory storage, LabVIEW driver |
Interfaces | LAN (TCP/IP, 10BASE-T/100BASE-TX) |
Power Supply | 100 to 240 V AC, 50 Hz/60 Hz, 35 VA maximum |
Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) |
Weight | 5.2 lbs (2.4 kg) |
Resistance Measurement Ranges | 3 mΩ maximum display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA 30 mΩ maximum display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA 300 mΩ maximum display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA 3 Ω maximum display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA 30 Ω maximum display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA 300 Ω maximum display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA 3 kΩ maximum display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA |
Basic Accuracy | ±0.5% rdg ±10 dgt (3 mΩ range), ±0.5% rdg ±5 dgt (30 mΩ range or more) |
Measurement Frequency | 1 kHz ±0.2 Hz |
Measurement Method | AC four-terminal method |
Voltage Measurement Ranges | 6 V (maximum display: 6.00000 V, resolution: 10 μV) 60 V (maximum display: 60.0000 V, resolution: 100 μV) 100 V (maximum display: 100.000 V, resolution: 1 mV) |
Response Time | 10 ms |
Functions | Contact check, zero adjustment (±1000 counts), pulse measurement, comparator (Hi/ IN/ Lo), statistical calculations (maximum 30,000), delay, average, panel saving/loading, memory storage, LabVIEW driver |
Interfaces | LAN (TCP/IP, 10BASE-T/100BASE-TX) |
Power Supply | 100 to 240 V AC, 50 Hz/60 Hz, 35 VA maximum |
Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) |
Weight | 5.2 lbs (2.4 kg) |