Measurement functions Number of channels: 16, for voltage measurement/temperature measurement with thermocouple
Input connectors Voltage input/Thermocouple input: screw-type terminal strip, recommended wire diameter *1, detachable terminal block (with cover) *1 Recommended cable, singlewire: 0.14 to 1.5 mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16 Input impedance: 1 M?, 850 k? with line fault detection ON, Max. rated voltage to earth: 33 Vrms or 70 V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Voltage measurement range 5m, 50m, 500m, 2 V/division, 4 ranges, full scale: 20 divisions, measurement range: ±100% of full scale, digital filter: 50/60/10 Hz, measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Temperature measurement range (Upper and lower limit values depend on measurement input range of sensor) 10°C/division (-100°C/ to +200°C), 50°C/division (-200°C/ to +1000°C), 100°C/division (-200°C/ to +2000°C), 3 ranges, full scale: 20 divisions, digital filter: 50/60/10 Hz, measurement resolution 1/1000 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Thermocouple range (JIS C 1602-1995) (ASTM E-988-96) K: -200 to 1350°C, J: -200 to 1200°C, E: -200 to 1000°C, T: -200 to 400°C, N: -200 to 1300°C, R: 0 to 1700°C, S: 0 to 1700°C, B: 400 to 1800°C, W (WRe5-26): 0 to 2000°C, reference junction compensation: internal/ external (switchable), line fault detection ON/OFF switchable
Accuracy Voltage: ±0.2% of full scale, thermocouple (K, J, E, T, N): ±0.05% of full scale ±1°C, (R, S, B, W): ±0.05% of full scale ±2°C (400°C or more), ±0.05% of full scale ±3.5°C (less than 400°C), reference junction compensation accuracy: ±1°C (added to measurement accuracy with internal reference junction compensation)
Max. allowable input 40 V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass approx. 170 (6.69in) W × 20 (0.79in) H × 183 (7.20in) D mm, approx. 385 g (13.6 oz)
Accessories Flathead screwdriver × 1, short bar × 2
What's included with the Hioki 8958
Hioki 8958 16 Ch SCANNER UNIT
Ask a question about Hioki 8958 16 Ch SCANNER UNIT
Measurement functions Number of channels: 16, for voltage measurement/temperature measurement with thermocouple
Input connectors Voltage input/Thermocouple input: screw-type terminal strip, recommended wire diameter *1, detachable terminal block (with cover) *1 Recommended cable, singlewire: 0.14 to 1.5 mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16 Input impedance: 1 M?, 850 k? with line fault detection ON, Max. rated voltage to earth: 33 Vrms or 70 V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Voltage measurement range 5m, 50m, 500m, 2 V/division, 4 ranges, full scale: 20 divisions, measurement range: ±100% of full scale, digital filter: 50/60/10 Hz, measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Temperature measurement range (Upper and lower limit values depend on measurement input range of sensor) 10°C/division (-100°C/ to +200°C), 50°C/division (-200°C/ to +1000°C), 100°C/division (-200°C/ to +2000°C), 3 ranges, full scale: 20 divisions, digital filter: 50/60/10 Hz, measurement resolution 1/1000 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Thermocouple range (JIS C 1602-1995) (ASTM E-988-96) K: -200 to 1350°C, J: -200 to 1200°C, E: -200 to 1000°C, T: -200 to 400°C, N: -200 to 1300°C, R: 0 to 1700°C, S: 0 to 1700°C, B: 400 to 1800°C, W (WRe5-26): 0 to 2000°C, reference junction compensation: internal/ external (switchable), line fault detection ON/OFF switchable
Accuracy Voltage: ±0.2% of full scale, thermocouple (K, J, E, T, N): ±0.05% of full scale ±1°C, (R, S, B, W): ±0.05% of full scale ±2°C (400°C or more), ±0.05% of full scale ±3.5°C (less than 400°C), reference junction compensation accuracy: ±1°C (added to measurement accuracy with internal reference junction compensation)
Max. allowable input 40 V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass approx. 170 (6.69in) W × 20 (0.79in) H × 183 (7.20in) D mm, approx. 385 g (13.6 oz)
Accessories Flathead screwdriver × 1, short bar × 2
Our website gives you access to the best pricing we can offer. We encourage you to use our Build a Quote tool to build yourself a quote with the item(s) you’re interested in.
Your quote will then be emailed to you with all of the information you require. This also locks in your pricing for 30 days!
Check your Order Status
Check the status of your online order by entering your information below. Verify your order information is correct and the email address is what was used when you placed your order.
Ask our experts
To ask our Hioki experts a question please include your contact details. * Required Fields
Email Me When Available
Receive updates on when this product will be available for ordering.
*We don’t share your email. You can unsubscribe at any time.
Be the first to know!
Be the first to know when we have news, discounts, special offers and promotions.
*We don’t share your email. You can unsubscribe at any time.
Be the first to receive updates!
The Energy Monitoring System You've Been Waiting For!
Launching 2022
*We don’t share your email. You can unsubscribe at any time.
Exclusive Member Store
Don’t have a Member Account? Our Member Store gives you access to the following advantages:
Exclusive Member Pricing*
Exclusive Special Offers
Free Shipping on Online Orders over $199
Express Checkouts
Access to an additional 200 000+ Products via our Extended Search tool
Multiple Shipping Addresses
Additional Shipping Options
*Where applicable. Some of our pricing is already discounted.