Hanna HI 98199 pH/EC/DO Meter with digital pH electrode

Model: HI 98199

Hanna HI 98199 pH/EC/DO Meter with digital pH electrode

Model: HI 98199

The meter is rugged as well as portable with a single digital probe input. It is equipped with a host of intuitive functions, including logging capabilities, making the tracking of measurements a breeze. Also, its digital probe input allows the connection of either a pH, conductivity, or dissolved oxygen probe.

The meter is rugged as well as portable with a single digital probe input. It is equipped with a host of intuitive functions, including logging capabilities, making the tracking of measurements a breeze. Also, its digital probe input allows the connection of either a pH, conductivity, or dissolved oxygen probe.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

OAKTON 35660-80 PCD380 3-Channel pH, ORP, Conductivity, TDS, Resistivity, Salinity, and DO Smart Meter Kit-

OAKTON 35660-80 PCD380 3-Channel pH, ORP, Conductivity, TDS, Resistivity, Salinity, and DO Smart Meter Kit

Model: 35660-80 | Order No: WD-35660-80

Featuring easy-to-read and accurate readings with auto-hold, auto-stable, and real-time measurements with stability indicators, the 3-channel pH, ORP, conductivity, TDS, resistivity, salinity, and DO smart meter kit utilize smart sensor technology for automatic sensor recognition. Stores up to 10,000 data sets with a date-and-time stamp for accurate and easy analysis. Quickly transfer data from meter to computer seamlessly via USB cable or wirelessly via Wi-Fi.


Not what you're looking for? Let’s do a search and help you find what you need.


Hanna HI 98199 Offers



Features

  • Measures pH, conductivity and dissolved oxygen
  • Digital display shows multiple measurements at once
  • Easy-to-use control panel with number keys
  • Logging function lets you store and review data
  • Includes a digital pH electrode with a long cable
  • Rugged construction holds up in most environments

Hanna HI 98199 Specifications


pH Range: 0.00 to 14.00 pH
Resolution: 0.01 pH
Accuracy: ±0.02 pH
Calibration: automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Temperature Compensation: Yes
mV Range: ±600.0 mV
Resolution: 0.1 mV
Accuracy: ±0.5 mV
EC Range: 0 to 200 mS/cm
Resolution: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
Accuracy: ±1.5% of reading or ±2 μS/cm whichever is greater
Calibration: automatic single-point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range: 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)
Resolution: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)
Accuracy: ±1% of reading or ±1 ppm (mg/L) whichever is greater
Calibration: based on conductivity calibration
EC/TDS Temperature Compensation Yes
Temperature Correction Coefficient 0.00 to 6.00%/°C
EC to TDS Conversion Factor 0.00 to 1.00
Reference Temperature 25°C or 20°C
Cell Type Four ring
Salinity (PSU) Range: 0.00 to 70.00 PSU
Resolution: 0.01 PSU
Accuracy: ±2% of reading or ±0.01 PSU whichever is greater
Calibration: based on conductivity calibration
Salinity (Seawater Sigma) Range: 0.0 to 50.0 σt, σ0, σ15
Resolution: 0.1 σt, σ0, σ15
Accuracy: ±1 σt, σ0, σ15
Calibration: based on conductivity calibration
Resistivity Range: 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resolution: 1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm
Calibration: based on conductivity calibration
Dissolved Oxygen Measurement Type: Galvanic
Range: 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Resolution: 0.1%; 0.01 ppm (mg/L)
Accuracy: 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg/L) ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading
Calibration: automatic one or two points at 0, 100% or one custom point
Atmospheric Pressure Resolution: 0.1 mmHg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy: ±3 mmHg within ±15 °C from the temperature during calibration
Calibration: automatic at one custom point
Temperature Range: 23 to 131°F (-5 to 55°C); 268.15 to 328.15 K
Resolution: 0.01°F (0.01°C); 0.01 K
Accuracy: ±0.27°F (±0.15°C); ±0.15 K
Calibration: automatic at one custom point
Compensation: automatic from 23 to 131°F (-5 to 55°C)
Logging Type: continuous logging or log-on-demand
Memory: 45000 records
Interval: one second to three hours
Connectivity via USB-C with Hanna software
Automatic Shut-Off Not used (disabled), 5, 10, 15, 20, 30, 60 minutes
Display dot matrix
Battery Type/Life 1.5 V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight)
IP Protection IP67
Environment 32 to 122°F (0 to 50°C); RH 100%
Dimensions 7.3 x 3.6 x 1.4” (185 x 93 x 35.2 mm)
Weight 14.2 oz (400 g)

What's included with the Hanna HI 98199

  • pH/EC/DO Meter
  • Quality Certificate
  • HI829113 Probe
  • 13' (4 m) Cable
  • pH Calibration Solution Sachets
  • PC Software
  • Micro USB Cable
  • Rugged Carrying Case
  • Batteries
  • User Manual

Ask a question about Hanna HI 98199 pH/EC/DO Meter with digital pH electrode

Customer Reviews for the Hanna HI 98199

Hanna HI 98199 Offers



Features

  • Measures pH, conductivity and dissolved oxygen
  • Digital display shows multiple measurements at once
  • Easy-to-use control panel with number keys
  • Logging function lets you store and review data
  • Includes a digital pH electrode with a long cable
  • Rugged construction holds up in most environments

Hanna HI 98199 Specifications


pH Range: 0.00 to 14.00 pH
Resolution: 0.01 pH
Accuracy: ±0.02 pH
Calibration: automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Temperature Compensation: Yes
mV Range: ±600.0 mV
Resolution: 0.1 mV
Accuracy: ±0.5 mV
EC Range: 0 to 200 mS/cm
Resolution: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
Accuracy: ±1.5% of reading or ±2 μS/cm whichever is greater
Calibration: automatic single-point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range: 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)
Resolution: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)
Accuracy: ±1% of reading or ±1 ppm (mg/L) whichever is greater
Calibration: based on conductivity calibration
EC/TDS Temperature Compensation Yes
Temperature Correction Coefficient 0.00 to 6.00%/°C
EC to TDS Conversion Factor 0.00 to 1.00
Reference Temperature 25°C or 20°C
Cell Type Four ring
Salinity (PSU) Range: 0.00 to 70.00 PSU
Resolution: 0.01 PSU
Accuracy: ±2% of reading or ±0.01 PSU whichever is greater
Calibration: based on conductivity calibration
Salinity (Seawater Sigma) Range: 0.0 to 50.0 σt, σ0, σ15
Resolution: 0.1 σt, σ0, σ15
Accuracy: ±1 σt, σ0, σ15
Calibration: based on conductivity calibration
Resistivity Range: 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resolution: 1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm
Calibration: based on conductivity calibration
Dissolved Oxygen Measurement Type: Galvanic
Range: 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Resolution: 0.1%; 0.01 ppm (mg/L)
Accuracy: 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg/L) ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading
Calibration: automatic one or two points at 0, 100% or one custom point
Atmospheric Pressure Resolution: 0.1 mmHg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy: ±3 mmHg within ±15 °C from the temperature during calibration
Calibration: automatic at one custom point
Temperature Range: 23 to 131°F (-5 to 55°C); 268.15 to 328.15 K
Resolution: 0.01°F (0.01°C); 0.01 K
Accuracy: ±0.27°F (±0.15°C); ±0.15 K
Calibration: automatic at one custom point
Compensation: automatic from 23 to 131°F (-5 to 55°C)
Logging Type: continuous logging or log-on-demand
Memory: 45000 records
Interval: one second to three hours
Connectivity via USB-C with Hanna software
Automatic Shut-Off Not used (disabled), 5, 10, 15, 20, 30, 60 minutes
Display dot matrix
Battery Type/Life 1.5 V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight)
IP Protection IP67
Environment 32 to 122°F (0 to 50°C); RH 100%
Dimensions 7.3 x 3.6 x 1.4” (185 x 93 x 35.2 mm)
Weight 14.2 oz (400 g)

What's included with the Hanna HI 98199

  • pH/EC/DO Meter
  • Quality Certificate
  • HI829113 Probe
  • 13' (4 m) Cable
  • pH Calibration Solution Sachets
  • PC Software
  • Micro USB Cable
  • Rugged Carrying Case
  • Batteries
  • User Manual

Ask a question about Hanna HI 98199 pH/EC/DO Meter with digital pH electrode

Customer Reviews for the Hanna HI 98199

More Hanna Products

Calibration Lab