This series of food and beverage grade tri-clamp process connection pressure transmitters offer pressure ranges from 0 to 30" WC through 0 to 1000 psi. Features a rugged design that also meets 3A sanitary standards for dairy applications, along with 316L stainless steel construction. Fitting sizes as small as 3/4" helps to reduce surface area exposure.
This series of food and beverage grade tri-clamp process connection pressure transmitters offer pressure ranges from 0 to 30" WC through 0 to 1000 psi. Features a rugged design that also meets 3A sanitary standards for dairy applications, along with 316L stainless steel construction. Fitting sizes as small as 3/4" helps to reduce surface area exposure.
Features
*NOTE: Depending on configuration
Applications
| Pressure Ranges | From 0 to 30" WC thru 0 to 1000 psi 2, 2 1/2 and 3" tri-clamp fitting (≥2 to 300 psi) 1, 1 1/2" tri-clamp fitting (≥2 to 1000 psi) 1/2 and ¾" tri-clamp fitting (≥50 to 1000 psi) |
| Supply Voltage | 13 to 37 Vdc |
| Output Signal (@ 70°F) | 4 to 20 mA ±2% FSO |
| Load Resistance | 1200Ω max. at 37 Vdc, 550Ω max. at 24 Vdc |
| Circuit Protection | RFI and EMI |
| Connection | 20 ft 6-conductor vented Hytrel jacketed cable |
| Static Accuracy (BFSL) | Hytrel jacketed, 4-conductor, 18 AWG with vent tube and hydrophobic filter, 8' long |
| Wetted Parts | 316 stainless steel, NEMA-4X (3A 74-03 compliant) rated |
| Housing | 316 stainless steel |
| Process Connection | Tri-clamp 1/2 through 3" |
| Pressure | Proof: 3X FSO Burst: 6X FSO |
| Operating Process | -20 to 200°F (-29 to 93°C) |
| Effect on Zero/Span | <±2% FSO/100°F |
| Weight | 14 oz. nominal, dependent on pressure fitting |
| Pressure Ranges | From 0 to 30" WC thru 0 to 1000 psi 2, 2 1/2 and 3" tri-clamp fitting (≥2 to 300 psi) 1, 1 1/2" tri-clamp fitting (≥2 to 1000 psi) 1/2 and ¾" tri-clamp fitting (≥50 to 1000 psi) |
| Supply Voltage | 13 to 37 Vdc |
| Output Signal (@ 70°F) | 4 to 20 mA ±2% FSO |
| Load Resistance | 1200Ω max. at 37 Vdc, 550Ω max. at 24 Vdc |
| Circuit Protection | RFI and EMI |
| Connection | 20 ft 6-conductor vented Hytrel jacketed cable |
| Static Accuracy (BFSL) | Hytrel jacketed, 4-conductor, 18 AWG with vent tube and hydrophobic filter, 8' long |
| Wetted Parts | 316 stainless steel, NEMA-4X (3A 74-03 compliant) rated |
| Housing | 316 stainless steel |
| Process Connection | Tri-clamp 1/2 through 3" |
| Pressure | Proof: 3X FSO Burst: 6X FSO |
| Operating Process | -20 to 200°F (-29 to 93°C) |
| Effect on Zero/Span | <±2% FSO/100°F |
| Weight | 14 oz. nominal, dependent on pressure fitting |