Fuji Electric PXR3 Series Temperature Controller

Fuji Electric PXR3 Series Temperature Controller

Digital thermostat PXR3 is an on-off temperature alarm that accepts signals from a thermocouple or a thermistor and transmits relay contact output signals when the input reaches the alarm setpoint. It is most suited to overheat detection of a wide range of equipment.

Digital thermostat PXR3 is an on-off temperature alarm that accepts signals from a thermocouple or a thermistor and transmits relay contact output signals when the input reaches the alarm setpoint. It is most suited to overheat detection of a wide range of equipment.

Configure This Product:

Front Panel Size
Control Output 1
Control Output 2
Control Output 3
Revision Code
Alarm Output
Power Supply
Additional Functions
Programming
To view your pricing & availability, choose your options and add this item to your cart.
Ordering Number
Digital thermostat PXR3 is an on-off temperature alarm that accepts signals from a thermocouple or a thermistor and transmits relay contact output signals when the input reaches the alarm setpoint. It is most suited to overheat detection of a wide range of equipment.
Your Price $
Availability
Quantity

Fuji Electric PXR3 Series Offers

Digital thermostat PXR3 is an on-off temperature alarm that accepts signals from a thermocouple or a thermistor and transmits relay contact output signals when the input reaches the alarm setpoint. It is most suited to overheat detection of a wide range of equipment.

Features

  • Compact design
  • Accepts thermocouples or thermistor
  • Temperature display
  • Alarm setting available in 1°C steps
  • Waterproof front panel
  • Two relay outputs (option)

Fuji Electric PXR3 Series Specifications

Range & accuracy Type J thermocouple: 0–800°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type K thermocouple: 0–1200°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type R thermocouple: 0–1600°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type T thermocouple: 0–400°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type E thermocouple: 0–600°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Thermistor: 0–100°C, accuracy ±4°C
Note 1: Switching between thermistor and thermocouple is not allowed.
Note 2: Thermocouple type setting can be changed by front key operation.
Note 3: Reading error of thermistor sensor or thermocouple is not included.
Measurement cycle ≤ 0.5 s
Burnout Thermocouple (UUU), thermocouple (LLL)
Input correction Configurable within ±10% of range
Display Green LED
Measured value, alarm setpoint, parameter name, parameter setpoint
Operation keys 3 keys
Alarm value setting resolution: 1°C
Key lock available
Alarm output SPST 1 or 2 points
High or low limit alarm (HL, HH, LL are available on two outputs version)
Mechanical life of contact: 10 million times
Contact capacity: 220 V AC or 30 V DC, 1A (resistive load)
Alarm hysteresis width: configurable within 0–110% of range
Power supply voltage 100–240 V AC, 50/60 Hz
Operating environment -10°C to +50°C, RH90% or less (non condensation)
Mounting Panel mount
Optional DIN rail mounting adapter (ZZP*CTK368715P1) allows rail-mount or wall-mount
Dimensions and weight 24 × 48 × 85 mm, approx. 150 g
Terminal Screw clamp terminal
Others For thermistor input version, a thermistor sensor is provided.

What's included with the Fuji Electric PXR3 Series

  • Fuji Electric PXR3 Series Temperature Controller

Ask a question about Fuji Electric PXR3 Series Temperature Controller

Customer Reviews for the Fuji Electric PXR3 Series

Fuji Electric PXR3 Series Offers

Digital thermostat PXR3 is an on-off temperature alarm that accepts signals from a thermocouple or a thermistor and transmits relay contact output signals when the input reaches the alarm setpoint. It is most suited to overheat detection of a wide range of equipment.

Features

  • Compact design
  • Accepts thermocouples or thermistor
  • Temperature display
  • Alarm setting available in 1°C steps
  • Waterproof front panel
  • Two relay outputs (option)

Fuji Electric PXR3 Series Specifications

Range & accuracy Type J thermocouple: 0–800°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type K thermocouple: 0–1200°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type R thermocouple: 0–1600°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type T thermocouple: 0–400°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Type E thermocouple: 0–600°C, accuracy ±0.5% FS ± 1 digit ± 1°C
Thermistor: 0–100°C, accuracy ±4°C
Note 1: Switching between thermistor and thermocouple is not allowed.
Note 2: Thermocouple type setting can be changed by front key operation.
Note 3: Reading error of thermistor sensor or thermocouple is not included.
Measurement cycle ≤ 0.5 s
Burnout Thermocouple (UUU), thermocouple (LLL)
Input correction Configurable within ±10% of range
Display Green LED
Measured value, alarm setpoint, parameter name, parameter setpoint
Operation keys 3 keys
Alarm value setting resolution: 1°C
Key lock available
Alarm output SPST 1 or 2 points
High or low limit alarm (HL, HH, LL are available on two outputs version)
Mechanical life of contact: 10 million times
Contact capacity: 220 V AC or 30 V DC, 1A (resistive load)
Alarm hysteresis width: configurable within 0–110% of range
Power supply voltage 100–240 V AC, 50/60 Hz
Operating environment -10°C to +50°C, RH90% or less (non condensation)
Mounting Panel mount
Optional DIN rail mounting adapter (ZZP*CTK368715P1) allows rail-mount or wall-mount
Dimensions and weight 24 × 48 × 85 mm, approx. 150 g
Terminal Screw clamp terminal
Others For thermistor input version, a thermistor sensor is provided.

What's included with the Fuji Electric PXR3 Series

  • Fuji Electric PXR3 Series Temperature Controller