Keeping Your World Up & Running®

GET YOUR Get Your GSA Pricing PRICING

FREE STUFF! VALUE ADDED KITS!

FREE SHIPPING ON ONLINE ORDERS OVER $99*

Fluke CNX t3000 Temperature Measurement Kit

Model: CNX-T3000-KIT

Fluke CNX t3000 Temperature Measurement Kit

Model: CNX-T3000-KIT

A complete wireless measurement system that lets you make primary measurements on your multimeter while simultaneously viewing temperature measurements from the remote K-Type wireless thermocouple module. Includes the CNX 3000 Multimeter and CNX t3000 K-Type Wireless Temperature Module.

A complete wireless measurement system that lets you make primary measurements on your multimeter while simultaneously viewing temperature measurements from the remote K-Type wireless thermocouple module. Includes the CNX 3000 Multimeter and CNX t3000 K-Type Wireless Temperature Module.

This product has been discontinued. Click here for the replacement model(s).


For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range 1ResolutionAccuracy 2 3
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRange 1ResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
)))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF 11 μF10 %
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
FunctionRange 1ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA 30.1 mA
mA DC 260.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range 1ResolutionAccuracy
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scaleTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA

FunctionOverload ProtectionOverload
mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54

Fluke CNX t3000 Wireless K-Type Temperature Module


Specifications
Range K-Type: -200 °C to 1372 °C
Resolution 0.1 °C
Accuracy ±[0.5 % + 0.3 °C] counts
Input terminals K-Type mini
LCD w/backlight 3 digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
MemoryRecord up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature scale ITS-90
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance CAT I per IEC/EN 61010-1:2010
EN/IEC 61010-2-030:2010
Pollution degree 2
Temperature coefficient 0.01 % of reading +0.03 °C per °C
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42 with thermocouple attached
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Click here for complete specifications on the Fluke CNX-T3000-KIT

Included in the Fluke CNX t3000 Temperature Measurement Kit:

  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case

Customer Reviews for the Fluke CNX-T3000-KIT

Ask a question about Fluke CNX t3000 Temperature Measurement Kit

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range 1ResolutionAccuracy 2 3
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRange 1ResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
)))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF 11 μF10 %
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
FunctionRange 1ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA 30.1 mA
mA DC 260.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range 1ResolutionAccuracy
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scaleTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA

FunctionOverload ProtectionOverload
mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54

Fluke CNX t3000 Wireless K-Type Temperature Module


Specifications
Range K-Type: -200 °C to 1372 °C
Resolution 0.1 °C
Accuracy ±[0.5 % + 0.3 °C] counts
Input terminals K-Type mini
LCD w/backlight 3 digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
MemoryRecord up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature scale ITS-90
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance CAT I per IEC/EN 61010-1:2010
EN/IEC 61010-2-030:2010
Pollution degree 2
Temperature coefficient 0.01 % of reading +0.03 °C per °C
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42 with thermocouple attached
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Click here for complete specifications on the Fluke CNX-T3000-KIT

Included in the Fluke CNX t3000 Temperature Measurement Kit:

  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case

Ask a question about Fluke CNX t3000 Temperature Measurement Kit

Customer Reviews for the Fluke CNX-T3000-KIT

More Fluke Products

Calibration Lab