Fluke 975V AirMeter w/ Air Velocity Probe

Model: 975V | UPC: 095969353090

Fluke 975V AirMeter w/ Air Velocity Probe

Model: 975V | UPC: 095969353090

CO2, CO, temperature, humidity, air velocity, MIN/MAX/AVG, backlight, alarms, datalogging with software/USB w/ Air Velocity Probe.

CO2, CO, temperature, humidity, air velocity, MIN/MAX/AVG, backlight, alarms, datalogging with software/USB w/ Air Velocity Probe.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

REED R9905 Data Logging Indoor Air Quality Meter-

REED R9905 Data Logging Indoor Air Quality Meter

Model: R9905

Measures carbon dioxide (CO2), temperature, humidity and automatically calculates time-weighted average (TWA) and short-term exposure Limit (STEL).


Not what you're looking for? Let’s do a search and help you find what you need.


Recommended Accessories


Fluke 975V Offers

Features

  • Calculates volumetric flow rate, and actual/standard velocity
  • Datalogging and downloading software included: Manual
  • Stores over 12,700 data samples over a user selectable time base
  • Articulated probe versions available ("-A")
  • Shipped as a kit which includes thermo-anemometer; straight or articulated probe; 4 alkaline batteries; USB cable and downloading software; manual; hard carrying case and NIST calibration certificate

Temperature

  • Range: -20 °C to 50 °C (-5 °F to 122 °F)
  • Display resolution: 0.1 °C (0.1 °F)
  • Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C; ± 0.5 °C/± 1.00°F from 5 °C to 40 °C; ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity

  • Range: 10 % to 90 % RH, non-condensing
  • Display Resolution: 1%
  • Accuracy: ± 2 % RH (10 % RH to 90 % RH)

Air velocity

  • Range: 50.0 fpm to 3000 fpm; 0.25 m/sec to 15 m/sec
  • Display Resolution: 1 fpm (0.005m/sec)
  • Accuracy: ±4 % or 4 fpm*; ±4 % or 0.02 m/sec* whichever is greater; *Accuracy specification only valid for velocity readings above 50 fpm

C0

  • Range: 0 to 500 ppm
  • Display Resolution: 1 ppm
  • Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH

C02

  • Range: 0 to 5000 ppm
  • Display Resolution: 1 ppm
  • Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Fluke 975V Specifications

Measured specifications
Temperature
Range -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution 0.1 °C (0.1 °F)
Accuracy ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range 10 % to 90 % RH, non-condensing
Display Resolution 1%
Accuracy ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range 50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution 1 fpm (0.005m/sec)
Accuracy ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
CO2
Range 0 to 500 ppm
Display Resolution 1 ppm
Accuracy ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH

Calculated specifications
Dew point temperature
Range -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution 0.1 °C (0.1 °F)
Accuracy ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution 0.1 °C, (0.1 °F)
Accuracy ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution 0.001 M3/min, (1 cfm)
Accuracy N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range 0 to 100%
Display Resolution 0.1
% outside air (based on CO2)
Range 0 to 100 %
Display Resolution 0.1 % N/A

General specifications
Operating and storage temperature

-20 °C to 50 °C (-4 °F to 122 °F)
Humidity

10 % to 90 % (non-condensing)
Altitude

Up to 2000 m (6562 ft)
Shock and vibration

MIL-PRF-28800F: Class 2
Multi-language interface

English, French, Spanish, Portuguese and German
Battery

Rechargeable Li-Ion (primary), three-AA (backup)
Data logging

25,000 records (continuous), 99 records (discrete)
Warranty

Two-years

Click here for complete specifications on the Fluke 975V

What's included with the Fluke 975V

  • Fluke 975V AirMeter w/ Air Velocity Probe

Click on a category to view a selection of compatible accessories with the Fluke 975V AirMeter w/ Air Velocity Probe.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TPAK ToolPak Magnetic Meter Hanger ToolPak
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.




Ask a question about Fluke 975V AirMeter w/ Air Velocity Probe

Customer Reviews for the Fluke 975V

Fluke 975V Offers

Features

  • Calculates volumetric flow rate, and actual/standard velocity
  • Datalogging and downloading software included: Manual
  • Stores over 12,700 data samples over a user selectable time base
  • Articulated probe versions available ("-A")
  • Shipped as a kit which includes thermo-anemometer; straight or articulated probe; 4 alkaline batteries; USB cable and downloading software; manual; hard carrying case and NIST calibration certificate

Temperature

  • Range: -20 °C to 50 °C (-5 °F to 122 °F)
  • Display resolution: 0.1 °C (0.1 °F)
  • Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C; ± 0.5 °C/± 1.00°F from 5 °C to 40 °C; ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity

  • Range: 10 % to 90 % RH, non-condensing
  • Display Resolution: 1%
  • Accuracy: ± 2 % RH (10 % RH to 90 % RH)

Air velocity

  • Range: 50.0 fpm to 3000 fpm; 0.25 m/sec to 15 m/sec
  • Display Resolution: 1 fpm (0.005m/sec)
  • Accuracy: ±4 % or 4 fpm*; ±4 % or 0.02 m/sec* whichever is greater; *Accuracy specification only valid for velocity readings above 50 fpm

C0

  • Range: 0 to 500 ppm
  • Display Resolution: 1 ppm
  • Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH

C02

  • Range: 0 to 5000 ppm
  • Display Resolution: 1 ppm
  • Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Fluke 975V Specifications

Measured specifications
Temperature
Range -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution 0.1 °C (0.1 °F)
Accuracy ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range 10 % to 90 % RH, non-condensing
Display Resolution 1%
Accuracy ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range 50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution 1 fpm (0.005m/sec)
Accuracy ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
CO2
Range 0 to 500 ppm
Display Resolution 1 ppm
Accuracy ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH

Calculated specifications
Dew point temperature
Range -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution 0.1 °C (0.1 °F)
Accuracy ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution 0.1 °C, (0.1 °F)
Accuracy ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution 0.001 M3/min, (1 cfm)
Accuracy N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range 0 to 100%
Display Resolution 0.1
% outside air (based on CO2)
Range 0 to 100 %
Display Resolution 0.1 % N/A

General specifications
Operating and storage temperature

-20 °C to 50 °C (-4 °F to 122 °F)
Humidity

10 % to 90 % (non-condensing)
Altitude

Up to 2000 m (6562 ft)
Shock and vibration

MIL-PRF-28800F: Class 2
Multi-language interface

English, French, Spanish, Portuguese and German
Battery

Rechargeable Li-Ion (primary), three-AA (backup)
Data logging

25,000 records (continuous), 99 records (discrete)
Warranty

Two-years

Click here for complete specifications on the Fluke 975V

What's included with the Fluke 975V

  • Fluke 975V AirMeter w/ Air Velocity Probe

Click on a category to view a selection of compatible accessories with the Fluke 975V AirMeter w/ Air Velocity Probe.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TPAK ToolPak Magnetic Meter Hanger ToolPak
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.




Ask a question about Fluke 975V AirMeter w/ Air Velocity Probe

Customer Reviews for the Fluke 975V

More Fluke Products