Keeping Your World Up & Running®

GET YOUR Get Your GSA Pricing PRICING

FREE STUFF! VALUE ADDED KITS!

FREE SHIPPING ON ONLINE ORDERS OVER $99*

Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Model: 414D/62-MAX+ | Order No: 414D/62MAX+ | UPC: 095969659239

Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Model: 414D/62-MAX+ | Order No: 414D/62MAX+ | UPC: 095969659239

The rugged Fluke 62 MAX+ IR Thermometer teamed with the easy to use Fluke 414D Laser Distance Meter. Configure, layout and troubleshoot electrical/HVAC/R problems quickly.

The rugged Fluke 62 MAX+ IR Thermometer teamed with the easy to use Fluke 414D Laser Distance Meter. Configure, layout and troubleshoot electrical/HVAC/R problems quickly.

This product has been discontinued. Click here for the replacement model(s).


Recommended Accessories

Fluke C50 Meter Case-
Fluke C550 Premium Tool Bag-

Fluke 414D/62-MAX+ Offers

Fluke 414D Features

  • Tripod mode allows you to mount to a tripod for measuring long distances
  • Stake out function
  • Enhanced Pythagoras calculation for determining distance indirectly from three other measurements
  • Audible keypad feedback
  • Storage of the last twenty measurements for quick recall of distance
  • Strong environmental protection with IP54 (water spray and dust proof) sealing
  • The most advanced laser technology for distance measurement
  • Instant measurement with one-button operation
  • Easy targeting with bright laser
  • Quick calculation of area (square footage) and volume
  • Easy addition and subtraction of measurements
  • Minimum/maximum function
  • Improved battery life from automatic shut-off feature
  • Pythagoras calculation for determining distance indirectly from two other measurements
  • Pouch with Fluke logo

Fluke 62MAX+ Features

  • Ergonomically designed: Completely redesigned for a more natural hand fit
  • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
  • Distance to spot: Precise laser technology makes for more accurate and repeatable measurements
  • Dual lasers: The 62 MAX+ has dual rotating lasers to help you identify area to be measured.The measurement area is the spot between the dots
  • Large, backlit display: Large screen makes data easier to read, even in dark areas
  • Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements
  • Alarm: Hi and Lo alarms for rapid display of measurements outside the limits
  • Power: Both the 62 MAX and 62 MAX+ are powered by a single, standard AA battery

Fluke 414D Specification

414D419D424D
Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3]± 1.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3] ± 2.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft80 m / 260 ft100 m / 330 ft
Typical Range[1] 40 m / 130 ft80 m / 260 ft80 m / 260 ft
Range at unfavorable condition[4] 35 m / 115 ft60 m / 195 ft60 m / 195 ft
Smallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
(10 / 50 / 100 m)
∅ laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m)
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No No ± 0.2°
Measuring tolerance to housing[5] No No ± 0.2°
Range No No 360°
General
Laser class 2
Laser type 635 nm, <1 mW
Protection class IP40 IP54
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurements
Up to 5,000
measurements
Size (H X W X L) 116mm Length
53mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
Weight (with batteries) 113 g 153 g 158 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F)

0 °C to +40 °C
(32 °F to +104 °F)
-25 °C to +70°C
(-13 °F to +158 °F)

-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle Not applicable Not applicable Tilt and compass
Maximum altitude 3000 m 3000 m 3000 m
Maximum relative humidity 85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.

Fluke 62 MAX+ Specifications

Specifications

Temperature Range

Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX <500 ms (95% of reading)
Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

Fluke 62 MAX 10:1 (calculated at 90% energy)
Fluke 62+ MAX 12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
Fluke 62 MAX 10 hours with laser and backlight on
Fluke 62+ MAX 8 hours with laser and backlight on

Physical Specifications

Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
Click here for complete specifications on the Fluke 414D/62-MAX+

What's included with the Fluke 414D/62-MAX+

  • Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
  • Click on a category to view a selection of compatible accessories with the Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit.





    Fluke C50 Meter Case C50
    Case includes an inside pocket, belt loop and inside meter strap.




    Fluke C550 Premium Tool Bag C550
    Tool Bag with steel reinforced frame.




    Fluke H5 Electrical Tester Holster H5
    Compatible with the Fluke T3 and T5 testers. Additionally, this electrical tester holster features a rugged fabric holster, flap for lead storage, and built-in belt loop.




    Customer Reviews for the Fluke 414D/62-MAX+

    Ask a question about Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

    Fluke 414D/62-MAX+ Offers

    Fluke 414D Features

    • Tripod mode allows you to mount to a tripod for measuring long distances
    • Stake out function
    • Enhanced Pythagoras calculation for determining distance indirectly from three other measurements
    • Audible keypad feedback
    • Storage of the last twenty measurements for quick recall of distance
    • Strong environmental protection with IP54 (water spray and dust proof) sealing
    • The most advanced laser technology for distance measurement
    • Instant measurement with one-button operation
    • Easy targeting with bright laser
    • Quick calculation of area (square footage) and volume
    • Easy addition and subtraction of measurements
    • Minimum/maximum function
    • Improved battery life from automatic shut-off feature
    • Pythagoras calculation for determining distance indirectly from two other measurements
    • Pouch with Fluke logo

    Fluke 62MAX+ Features

    • Ergonomically designed: Completely redesigned for a more natural hand fit
    • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
    • Distance to spot: Precise laser technology makes for more accurate and repeatable measurements
    • Dual lasers: The 62 MAX+ has dual rotating lasers to help you identify area to be measured.The measurement area is the spot between the dots
    • Large, backlit display: Large screen makes data easier to read, even in dark areas
    • Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements
    • Alarm: Hi and Lo alarms for rapid display of measurements outside the limits
    • Power: Both the 62 MAX and 62 MAX+ are powered by a single, standard AA battery

    Fluke 414D Specification

    414D419D424D
    Distance Measurement
    Typical Measuring Tolerance[1] ± 2.0 mm [3]± 1.0 mm [3]
    Maximum Measuring Tolerance[2] ± 3.0 mm [3] ± 2.0 mm [3]
    Range at Leica target plate GZM26 50 m / 165 ft80 m / 260 ft100 m / 330 ft
    Typical Range[1] 40 m / 130 ft80 m / 260 ft80 m / 260 ft
    Range at unfavorable condition[4] 35 m / 115 ft60 m / 195 ft60 m / 195 ft
    Smallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
    (10 / 50 / 100 m)
    ∅ laser point at distances 6 /30 / 60 mm
    (10 / 50 / 100 m)
    6 /30 / 60 mm
    (10 / 50 / 100 m)
    Tilt measurement
    Measuring tolerance to laser beam[5] No No ± 0.2°
    Measuring tolerance to housing[5] No No ± 0.2°
    Range No No 360°
    General
    Laser class 2
    Laser type 635 nm, <1 mW
    Protection class IP40 IP54
    Automatic laser off After 90 seconds
    Automatic power off after 180 seconds
    Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
    measurements
    Up to 5,000
    measurements
    Size (H X W X L) 116mm Length
    53mm Width
    33mm Depth
    127mm Length
    56mm Width
    33mm Depth
    127mm Length
    56mm Width
    33mm Depth
    Weight (with batteries) 113 g 153 g 158 g
    Temperature range: Storage Operation -25 °C to +70°C
    (-13 °F to +158 °F)

    0 °C to +40 °C
    (32 °F to +104 °F)
    -25 °C to +70°C
    (-13 °F to +158 °F)

    -10 °C to +50 °C
    (14 °F to +122 °F)
    Calibration cycle Not applicable Not applicable Tilt and compass
    Maximum altitude 3000 m 3000 m 3000 m
    Maximum relative humidity 85% at 20 °F to 120°F
    (-7 °C to 50 °C)
    85% at 20 °F to 120°F
    (-7 °C to 50 °C)
    85% at 20 °F to 120°F
    (-7 °C to 50 °C)
    Safety IEC Standard No. 61010-1:2001
    EN60825-1:2007 (Class II)
    EMC EN 55022:2010
    EN 61000-4-3:2010
    EN 61000-4-8:2010
    [1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
    [2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
    [3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
    [4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
    [5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.

    Fluke 62 MAX+ Specifications

    Specifications

    Temperature Range

    Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
    Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
    Accuracy
    Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
    -10 °C to 0 °C: ±2.0
    -30 °C to -10 °C: ±3.0
    Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater
    -10 °C to 0 °C: ±2.0
    -30 °C to -10 °C: ±3.0
    Response Time (95%)
    Fluke 62 MAX <500 ms (95% of reading)
    Fluke 62+ MAX <300 ms (95% of reading)
    Spectral Response 8 to 14 microns
    Emissivity 0.10 to 1.00

    Optical Resolution

    Fluke 62 MAX 10:1 (calculated at 90% energy)
    Fluke 62+ MAX 12:1 (calculated at 90% energy)
    Display Resolution
    0.1 °C (0.2 °F)
    Repeatability of Readings
    Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
    Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
    Power
    AA battery
    Battery Life
    Fluke 62 MAX 10 hours with laser and backlight on
    Fluke 62+ MAX 8 hours with laser and backlight on

    Physical Specifications

    Weight 255 g (8.99 oz)
    Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
    Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
    Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
    Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
    Operating Altitude 2000 meters above mean sea level
    Storage Altitude 12,000 meters above mean sea level
    IP Rating IP 54 per IEC 60529
    Drop Test 3 meters
    Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
    EMC EN 61326-1:2006 EN 61326-2:2006

    Standards and Agency Approval

    Compliance EN/IEC 61010-1: 2001
    Laser Safety FDA and EN 60825-1 Class II
    Click here for complete specifications on the Fluke 414D/62-MAX+

    What's included with the Fluke 414D/62-MAX+

  • Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
  • Click on a category to view a selection of compatible accessories with the Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit.





    Fluke C50 Meter Case C50
    Case includes an inside pocket, belt loop and inside meter strap.




    Fluke C550 Premium Tool Bag C550
    Tool Bag with steel reinforced frame.




    Fluke H5 Electrical Tester Holster H5
    Compatible with the Fluke T3 and T5 testers. Additionally, this electrical tester holster features a rugged fabric holster, flap for lead storage, and built-in belt loop.




    Ask a question about Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

    Customer Reviews for the Fluke 414D/62-MAX+

    More Fluke Products

    Calibration Lab