Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Model: TI125/IND-30HZ | UPC: 095969674584

Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Model: TI125/IND-30HZ | UPC: 095969674584

Includes both the Ti125 Thermal Imager and the complete CNX-3000 Industrial Kit. A complete wireless measurement and thermal system that lets you make primary measurements on your multimeter while simultaneously viewing measurements from the remote voltage and current modules.

Includes both the Ti125 Thermal Imager and the complete CNX-3000 Industrial Kit. A complete wireless measurement and thermal system that lets you make primary measurements on your multimeter while simultaneously viewing measurements from the remote voltage and current modules.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Fluke Ti300+ Thermal Imaging Camera, 320 x 240, -4 to 1202°F-

Fluke Ti300+ Thermal Imaging Camera, 320 x 240, -4 to 1202°F

Model: Ti300+ 60HZ | Order No: Ti300+60HZ

Identify issues before they occur and capture high-quality and focused images with this thermal imager that features LaserSharp™ AutoFocus and a 320 x 240 resolution. Easy to use and reliable, this thermal imager provides the accuracy required to expose temperature differentials or demonstrate progressive heat changes over time.


Not what you're looking for? Let’s do a search and help you find what you need.


Fluke TI125/IND-30HZ Specifications

Infrared resolution 160 x 120
Focus mechanism IR-OptiFlex™ focus system
Thermal sensitivity (NETD) < 0.10°C at 30 °C target temp (100 mK)
Temperatue measurement range
(not calibrated below -10 °C)
-20 °C to +350 °C
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal,
whichever is greater)
IR-Fusion® Technology Full infrared, PIP, Full visible,
AutoBlend™, Color alarms
IR-Photonotes® annotation system Yes
Electronic compass Yes
Multi-mode video recording .AVI w/ MPEG encoding and
.IS3 radiometric
Voice annotation Yes (60 seconds)
Laser pointer/torch Laser pointer and torch
Streaming video output USB video output
Rechargeable batteries
(4+ hours each)
2 rugged lithium-ion smart batteries
Ruggedness and reliability 2-meter drop test, IP54 and
integrated lens cap
Weight 0.726 kg
Warranty 2 years, with additional available
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
RangeResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage ranges are specified from 1 % of range to 100 % of range.
Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
)))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF1 μF10 %
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
FunctionRangeResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA0.1 mA
mA DC60.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
All AC current ranges are specified from 5 % of range to 100 % of range.
Input burden voltage (typical): 400 mA input 2 mV/mA.
400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz 
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scaleTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA
FunctionOverload ProtectionOverload
mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage
RangeResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
6.000 V0.001 V1.0 % + 32.0 % + 3
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage  ranges are specified  from 1 % of range  to 100  % of range.
Crest factor of ≤ 3 at full scale  up to 500  V, decreasing linearly  to crest  factor ≤ 1.5 at 1000 V.
For non-sinusoidal waveforms, add  -(2 % of reading + 2 % full scale) typical, for crest  factor up to 3.
General Specifications

LCD w/backlight

3½  digits, 6000 counts,  updates 4/sec

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400  Hours

Memory

Record up to 65,000 readings

Unbound listen interval

5 seconds

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10  °C to +50 °C

Storage temperature

-40  °C to +60 °C

Operating humidity

90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600  V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008

Pollution degree

2

Temperature coefficient

0.1 X (specified  accuracy)/°C (< 18 °C or > 28 °C)

Safety rating

CAT IV 600  V, CAT III 1000 V

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42

Size  (HxWxD)

16.5  cm x 6.35  cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)

Weight

.22 kg (8 oz)

Specifications
Range2500 A AC
Resolution0.1 A
Accuracy3 % ± 5 digits
Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display3-1/2 digits,  LCD w/backlight
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
Memory recordup to 65,000 readings
Unbound listen interval5 seconds
RF communications2.4 GHZ ISM Band
RF communication range20 Meters
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMCEN 61326-1:2006
Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree2
Temperature coefficientAdd 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP42
Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm
 (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
Jaw opening25.4 cm (10 in) coil
Click here for complete specifications on the Fluke TI125/IND-30HZ

What's included with the Fluke TI125/IND-30HZ

  • Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Click on a category to view a selection of compatible accessories with the Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TI-SBP3 Spare Battery Pack TI-SBP3
Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.




Fluke i2500-10 iFlex Flexible 10" Current Probe i2500-10
The iFlex 2500 is a 10" flexible current probe that offers a measuring capability up to 2500 A AC current and up to 1000 V AC.




Fluke C280 Polyester Soft Carrying Case C280
Compatible with Fluke 287 and 289 DMMs or other similar format test tools




Fluke TL175 TwistGuard Test Leads Set TL175
Built from WearGuard lead wire and silicone insulation, this test lead has an adjustable tip shroud that retracts and extends from 0.75 to 0.16" when you twist it. Additionally, the patented TwistGuard design allows easy adjustments to reduce or increase tip exposure to comply with new electrical safety requirements.




Fluke TL224 SureGrip Silicone Insulated Test Leads TL224
Provides convenience and variety for test lead configurations by attaching clips, hooks, and grabbers as needed.




Fluke AC285 SureGrip Alligator Clips AC285
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.








Ask a question about Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Customer Reviews for the Fluke TI125/IND-30HZ

Fluke TI125/IND-30HZ Specifications

Infrared resolution 160 x 120
Focus mechanism IR-OptiFlex™ focus system
Thermal sensitivity (NETD) < 0.10°C at 30 °C target temp (100 mK)
Temperatue measurement range
(not calibrated below -10 °C)
-20 °C to +350 °C
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal,
whichever is greater)
IR-Fusion® Technology Full infrared, PIP, Full visible,
AutoBlend™, Color alarms
IR-Photonotes® annotation system Yes
Electronic compass Yes
Multi-mode video recording .AVI w/ MPEG encoding and
.IS3 radiometric
Voice annotation Yes (60 seconds)
Laser pointer/torch Laser pointer and torch
Streaming video output USB video output
Rechargeable batteries
(4+ hours each)
2 rugged lithium-ion smart batteries
Ruggedness and reliability 2-meter drop test, IP54 and
integrated lens cap
Weight 0.726 kg
Warranty 2 years, with additional available
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
RangeResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage ranges are specified from 1 % of range to 100 % of range.
Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
)))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF1 μF10 %
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
FunctionRangeResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA0.1 mA
mA DC60.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
All AC current ranges are specified from 5 % of range to 100 % of range.
Input burden voltage (typical): 400 mA input 2 mV/mA.
400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz 
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scaleTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA
FunctionOverload ProtectionOverload
mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage
RangeResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
6.000 V0.001 V1.0 % + 32.0 % + 3
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage  ranges are specified  from 1 % of range  to 100  % of range.
Crest factor of ≤ 3 at full scale  up to 500  V, decreasing linearly  to crest  factor ≤ 1.5 at 1000 V.
For non-sinusoidal waveforms, add  -(2 % of reading + 2 % full scale) typical, for crest  factor up to 3.
General Specifications

LCD w/backlight

3½  digits, 6000 counts,  updates 4/sec

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400  Hours

Memory

Record up to 65,000 readings

Unbound listen interval

5 seconds

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10  °C to +50 °C

Storage temperature

-40  °C to +60 °C

Operating humidity

90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600  V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008

Pollution degree

2

Temperature coefficient

0.1 X (specified  accuracy)/°C (< 18 °C or > 28 °C)

Safety rating

CAT IV 600  V, CAT III 1000 V

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42

Size  (HxWxD)

16.5  cm x 6.35  cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)

Weight

.22 kg (8 oz)

Specifications
Range2500 A AC
Resolution0.1 A
Accuracy3 % ± 5 digits
Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display3-1/2 digits,  LCD w/backlight
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
Memory recordup to 65,000 readings
Unbound listen interval5 seconds
RF communications2.4 GHZ ISM Band
RF communication range20 Meters
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMCEN 61326-1:2006
Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree2
Temperature coefficientAdd 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP42
Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm
 (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
Jaw opening25.4 cm (10 in) coil
Click here for complete specifications on the Fluke TI125/IND-30HZ

What's included with the Fluke TI125/IND-30HZ

  • Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Click on a category to view a selection of compatible accessories with the Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TI-SBP3 Spare Battery Pack TI-SBP3
Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.




Fluke i2500-10 iFlex Flexible 10" Current Probe i2500-10
The iFlex 2500 is a 10" flexible current probe that offers a measuring capability up to 2500 A AC current and up to 1000 V AC.




Fluke C280 Polyester Soft Carrying Case C280
Compatible with Fluke 287 and 289 DMMs or other similar format test tools




Fluke TL175 TwistGuard Test Leads Set TL175
Built from WearGuard lead wire and silicone insulation, this test lead has an adjustable tip shroud that retracts and extends from 0.75 to 0.16" when you twist it. Additionally, the patented TwistGuard design allows easy adjustments to reduce or increase tip exposure to comply with new electrical safety requirements.




Fluke TL224 SureGrip Silicone Insulated Test Leads TL224
Provides convenience and variety for test lead configurations by attaching clips, hooks, and grabbers as needed.




Fluke AC285 SureGrip Alligator Clips AC285
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.








Ask a question about Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Customer Reviews for the Fluke TI125/IND-30HZ

More Fluke Products

Fluke Made for more!