Keeping Your World Up & Running®

GET YOUR Get Your GSA Pricing PRICING

FREE STUFF! VALUE ADDED KITS!

FREE SHIPPING ON ONLINE ORDERS OVER $99*

Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Model: TI125/IND-30HZ | UPC: 095969674584

Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

Model: TI125/IND-30HZ | UPC: 095969674584

Includes both the Ti125 Thermal Imager and the complete CNX-3000 Industrial Kit. A complete wireless measurement and thermal system that lets you make primary measurements on your multimeter while simultaneously viewing measurements from the remote voltage and current modules.

Includes both the Ti125 Thermal Imager and the complete CNX-3000 Industrial Kit. A complete wireless measurement and thermal system that lets you make primary measurements on your multimeter while simultaneously viewing measurements from the remote voltage and current modules.

This product has been discontinued. Contact us for more information.


Fluke Ti125 Specs:

Infrared resolution 160 x 120
Focus mechanism IR-OptiFlex™ focus system
Thermal sensitivity (NETD) < 0.10°C at 30 °C target temp (100 mK)
Temperatue measurement range
(not calibrated below -10 °C)
-20 °C to +350 °C
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal,
whichever is greater)
IR-Fusion® Technology Full infrared, PIP, Full visible,
AutoBlend™, Color alarms
IR-Photonotes® annotation system Yes
Electronic compass Yes
Multi-mode video recording .AVI w/ MPEG encoding and
.IS3 radiometric
Voice annotation Yes (60 seconds)
Laser pointer/torch Laser pointer and torch
Streaming video output USB video output
Rechargeable batteries
(4+ hours each)
2 rugged lithium-ion smart batteries
Ruggedness and reliability 2-meter drop test, IP54 and
integrated lens cap
Weight 0.726 kg
Warranty 2 years, with additional available

Fluke CNX-3000 Industrial System Specs:

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage ranges are specified from 1 % of range to 100 % of range.
Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRange ResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
)))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF 1 μF10 %
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
FunctionRange ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA 0.1 mA
mA DC 60.00 mA0.01 mA0.5 % + 3
400.0 mA0.1 mA
All AC current ranges are specified from 5 % of range to 100 % of range.
Input burden voltage (typical): 400 mA input 2 mV/mA.
400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range ResolutionAccuracy
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
FunctionOverload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scaleTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA

FunctionOverload ProtectionOverload
mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life300 hours minimum
TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency2.4 GHz ISM Band 20 meter range
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP54

Fluke CNX v3000 AC Wireless Voltage Module Specifications:

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage
Range ResolutionAccuracy
45 Hz to 500 Hz500 Hz to 1 kHz
6.000 V0.001 V1.0 % + 32.0 % + 3
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
All AC voltage  ranges are specified  from 1 % of range  to 100  % of range.
Crest factor of ≤ 3 at full scale  up to 500  V, decreasing linearly  to crest  factor ≤ 1.5 at 1000 V.
For non-sinusoidal waveforms, add  -(2 % of reading + 2 % full scale) typical, for crest  factor up to 3.

General Specifications

LCD w/backlight

3½  digits, 6000 counts,  updates 4/sec

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400  Hours

Memory

Record up to 65,000 readings

Unbound listen interval

5 seconds

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10  °C to +50 °C

Storage temperature

-40  °C to +60 °C

Operating humidity

90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600  V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008

Pollution degree

2

Temperature coefficient

0.1 X (specified  accuracy)/°C (< 18 °C or > 28 °C)

Safety rating

CAT IV 600  V, CAT III 1000 V

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42

Size  (HxWxD)

16.5  cm x 6.35  cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)

Weight

.22 kg (8 oz)

CNX i3000 iFlex AC Wireless Current Module Specifications:

Specifications
Range2500 A AC
Resolution0.1 A
Accuracy3 % ± 5 digits
Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display3-1/2 digits,  LCD w/backlight
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
Memory recordup to 65,000 readings
Unbound listen interval5 seconds
RF communications2.4 GHZ ISM Band
RF communication range20 Meters
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMCEN 61326-1:2006
Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree2
Temperature coefficientAdd 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) ratingIP42
Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm
 (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
Jaw opening25.4 cm (10 in) coil
Click here for complete specifications on the Fluke TI125/IND-30HZ

What's included with the Fluke TI125/IND-30HZ

  • Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit
  • Click on a category to view a selection of compatible accessories with the Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit.



    Fluke BOOK-ITP Introduction to Thermography Principles Book BOOK-ITP
    Provides an overview of the latest information on the safe, efficient, and practical use of thermal imagers. Full-color, soft-cover book that depicts and describes many thermal images of electrical, electro-mechanical, HVAC/R, process, and building inspection applications with real-world examples illustrate commercial, industrial, municipal, and residential environments and applications.




    Fluke TI-SBP3 Spare Battery Pack TI-SBP3
    Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.








    Fluke i2500-10 iFlex Flexible 10" Current Probe i2500-10
    The iFlex 2500 is a 10" flexible current probe that offers a measuring capability up to 2500 A AC current and up to 1000 V AC.




    Fluke C280 Polyester Soft Carrying Case C280
    Compatible with Fluke 287 and 289 DMMs or other similar format test tools




    Fluke AC285 SureGrip™ Alligator Clips AC285
    Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.




    Fluke TL175 TwistGuard Test Leads Set TL175
    By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 inch to 0.16 inch).




    Fluke TL224 SureGrip™ Silicone Insulated Test Leads TL224
    These insulated test leads provide the convenience and variety for test lead configurations by attaching clips, hooks and grabbers as needed.




    Customer Reviews for the Fluke TI125/IND-30HZ

    Ask a question about Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

    Fluke Ti125 Specs:

    Infrared resolution 160 x 120
    Focus mechanism IR-OptiFlex™ focus system
    Thermal sensitivity (NETD) < 0.10°C at 30 °C target temp (100 mK)
    Temperatue measurement range
    (not calibrated below -10 °C)
    -20 °C to +350 °C
    Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal,
    whichever is greater)
    IR-Fusion® Technology Full infrared, PIP, Full visible,
    AutoBlend™, Color alarms
    IR-Photonotes® annotation system Yes
    Electronic compass Yes
    Multi-mode video recording .AVI w/ MPEG encoding and
    .IS3 radiometric
    Voice annotation Yes (60 seconds)
    Laser pointer/torch Laser pointer and torch
    Streaming video output USB video output
    Rechargeable batteries
    (4+ hours each)
    2 rugged lithium-ion smart batteries
    Ruggedness and reliability 2-meter drop test, IP54 and
    integrated lens cap
    Weight 0.726 kg
    Warranty 2 years, with additional available

    Fluke CNX-3000 Industrial System Specs:

    For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

    Detailed Specifications
    AC Voltage
    Range ResolutionAccuracy
    45 Hz to 500 Hz500 Hz to 1 kHz
    600.0 mV0.1 mV1.0 % + 32.0 % + 3
    6.000 V0.001 V
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V
    All AC voltage ranges are specified from 1 % of range to 100 % of range.
    Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    FunctionRange ResolutionAccuracy
    mV600.0 mV0.1 mV0.09 % + 2
    V6.000 V0.001 V0.09 % + 2
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V0.15 % + 2
    )))600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω600.0 Ω0.1 Ω0.5 % + 2
    6.000 kΩ0.001 kΩ0.5 % + 1
    60.00 kΩ0.01 kΩ
    60.00 kΩ0.1 kΩ
    600.0 kΩ0.001 MΩ
    50.00 MΩ0.01 MΩ1.5 % + 3
    Diode test2.000 V0.001 V1 % + 2
    µF1000 nF1 nF1.2 % + 2
    10.00 μF0.01 μF
    100.0 μF0.1 μF
    9999 μF 1 μF10 %
    In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

    AC and DC Current
    FunctionRange ResolutionAccuracy
    mA AC
    (45 Hz to 1 kHz)
    60.00 mA0.01 mA1.5 % + 3
    400.0 mA 0.1 mA
    mA DC 60.00 mA0.01 mA0.5 % + 3
    400.0 mA0.1 mA
    All AC current ranges are specified from 5 % of range to 100 % of range.
    Input burden voltage (typical): 400 mA input 2 mV/mA.
    400.0 mA accuracy specified up to 600 mA overload.

    Frequency
    Range ResolutionAccuracy
    99.99 Hz0.01 Hz0.1 % + 1
    999.9 Hz0.1 Hz
    9.999 kHz0.001 kHz
    99.99 kHz0.01 kHz
    Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

    Input Characteristics
    FunctionOverload
    Protection
    Input Impedance
    (nominal)
    Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
    1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
    1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
    1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
    Open circuit test voltageFull scaleTypical short circuit current
    To 6 MΩ50 MΩ
    1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
    1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA

    FunctionOverload ProtectionOverload
    mAFused, 44/100 A, 1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum

    MIN/MAX Recording
    FunctionAccuracy
    DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
    AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

    General Specifications
    Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
    Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD)Update rate: 4/sec
    Volts, amps, ohms: 6000 counts
    Frequency: 10,000 counts
    Capacitance: 1,000 counts
    Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life300 hours minimum
    TemperatureOperating: -10 °C to 50 °C Storage: -40 °C to 60 °C
    Relative humidity0 % to 90 % (0 °C to 35 °C)
    0 % to 75 % (35 °C to 40 °C)
    0 % to 45 % (40 °C to 50 °C)
    AltitudeOperating: 2,000 m
    Storage: 12,000 m
    Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Wireless frequency2.4 GHz ISM Band 20 meter range
    Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
    Weight340 g (12 oz)
    Safety standardsUS ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    CE European: IEC/EN 61010-1:2010
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) ratingIP54

    Fluke CNX v3000 AC Wireless Voltage Module Specifications:

    Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

    AC Voltage
    Range ResolutionAccuracy
    45 Hz to 500 Hz500 Hz to 1 kHz
    6.000 V0.001 V1.0 % + 32.0 % + 3
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V
    All AC voltage  ranges are specified  from 1 % of range  to 100  % of range.
    Crest factor of ≤ 3 at full scale  up to 500  V, decreasing linearly  to crest  factor ≤ 1.5 at 1000 V.
    For non-sinusoidal waveforms, add  -(2 % of reading + 2 % full scale) typical, for crest  factor up to 3.

    General Specifications

    LCD w/backlight

    3½  digits, 6000 counts,  updates 4/sec

    Battery type

    2 AA, NEDA 15 A, IEC LR6

    Battery life

    400  Hours

    Memory

    Record up to 65,000 readings

    Unbound listen interval

    5 seconds

    RF communications

    2.4 GHZ ISM Band

    RF communication range

    20 Meters

    Operating temperature

    -10  °C to +50 °C

    Storage temperature

    -40  °C to +60 °C

    Operating humidity

    90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C

    EMC

    EN 61326-1:2006

    Safety compliance

    EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600  V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
    EN/IEC 61010-031:2002+A1:2008

    Pollution degree

    2

    Temperature coefficient

    0.1 X (specified  accuracy)/°C (< 18 °C or > 28 °C)

    Safety rating

    CAT IV 600  V, CAT III 1000 V

    Certifications

    CSA, FCC T68-FWCS IC:6627A-FWCS

    Ingress Protection (IP) rating

    IP42

    Size  (HxWxD)

    16.5  cm x 6.35  cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)

    Weight

    .22 kg (8 oz)

    CNX i3000 iFlex AC Wireless Current Module Specifications:

    Specifications
    Range2500 A AC
    Resolution0.1 A
    Accuracy3 % ± 5 digits
    Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
    Display3-1/2 digits,  LCD w/backlight
    Log rate/interval1 sec minimum/adjustable by PC or front panel
    Battery type2 AA, NEDA 15 A, IEC LR6
    Battery life400 hours
    Memory recordup to 65,000 readings
    Unbound listen interval5 seconds
    RF communications2.4 GHZ ISM Band
    RF communication range20 Meters
    Operating temperature-10 °C to +50 °C
    Storage temperature-40 °C to +60 °C
    Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
    EMCEN 61326-1:2006
    Safety complianceEN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV
    EN/IEC 61010-2-030:2010
    EN/IEC 610101-2-031:2002
    EN/IEC 61010-2-032:2002
    Pollution degree2
    Temperature coefficientAdd 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
    Safety ratingCAT IV 600 V, CAT III 1000 V
    CertificationsCSA, FCC T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) ratingIP42
    Size (HxWxD)16.5 cm x 6.35 cm x 3.56 cm
     (6.5 in x 2.5 in x 1.4 in)
    Weight.22 kg (8 oz)
    Jaw opening25.4 cm (10 in) coil
    Click here for complete specifications on the Fluke TI125/IND-30HZ

    What's included with the Fluke TI125/IND-30HZ

  • Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit
  • Click on a category to view a selection of compatible accessories with the Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit.



    Fluke BOOK-ITP Introduction to Thermography Principles Book BOOK-ITP
    Provides an overview of the latest information on the safe, efficient, and practical use of thermal imagers. Full-color, soft-cover book that depicts and describes many thermal images of electrical, electro-mechanical, HVAC/R, process, and building inspection applications with real-world examples illustrate commercial, industrial, municipal, and residential environments and applications.




    Fluke TI-SBP3 Spare Battery Pack TI-SBP3
    Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.








    Fluke i2500-10 iFlex Flexible 10" Current Probe i2500-10
    The iFlex 2500 is a 10" flexible current probe that offers a measuring capability up to 2500 A AC current and up to 1000 V AC.




    Fluke C280 Polyester Soft Carrying Case C280
    Compatible with Fluke 287 and 289 DMMs or other similar format test tools




    Fluke AC285 SureGrip™ Alligator Clips AC285
    Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.




    Fluke TL175 TwistGuard Test Leads Set TL175
    By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 inch to 0.16 inch).




    Fluke TL224 SureGrip™ Silicone Insulated Test Leads TL224
    These insulated test leads provide the convenience and variety for test lead configurations by attaching clips, hooks and grabbers as needed.




    Ask a question about Fluke Ti125 Thermal Imager and CNX-3000 Industrial System Combo Kit

    Customer Reviews for the Fluke TI125/IND-30HZ

    More Fluke Products

    Calibration Lab