Fluke Networks DSX2-5-IE-K1 CableAnalyzer Industrial Ethernet Copper Certifier Kit, versiv 2

Model: DSX2-5-IE-K1 | UPC: 754082149675

Fluke Networks DSX2-5-IE-K1 CableAnalyzer Industrial Ethernet Copper Certifier Kit, versiv 2

Model: DSX2-5-IE-K1 | UPC: 754082149675

A copper cabling certification tester for industrial Ethernet networks, supporting RJ45 and M12 connectors for commissioning and documentation. It delivers fast pass/fail certification with detailed diagnostics to troubleshoot issues like crosstalk and return loss.

A copper cabling certification tester for industrial Ethernet networks, supporting RJ45 and M12 connectors for commissioning and documentation. It delivers fast pass/fail certification with detailed diagnostics to troubleshoot issues like crosstalk and return loss.

Your Price $15471.00 USD
Availability 2 to 3 Weeks
Quantity

Fluke Networks DSX2-5-IE-K1 Offers

The DSX-5000 CableAnalyzer improves the efficiency of copper certification with unmatched speed for testing Cat 6A and Class FAwhile meeting draft IEC Level V – the most stringent accuracy requirement. The ProjX Management System helps ensure jobs are done correctly the first time and helps tracks progress from set-up to systems acceptance. Versiv platform supports modules for fiber testing (Both OLTS and OTDR) and Wi-Fi Analysis and Ethernet troubleshooting. The platform is easily upgradeable to support future standards. Troubleshoot faults faster with the Taptive user interface which graphically displays the source of failures including crosstalk, return loss and shield faults. Analyze test results and create professional test reports using LinkWare™ Management Software.

Fluke Networks' DSX-5000 CableAnalyzer is Intertek (ETL) Verified in accordance with the IEC-61935-1 specifications for accuracy Level IV, and draft accuracy Level V, and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

Unique Features:

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem

Standards:

  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA/EIA-568-C.2
  • Next generation balance drafts – IEEE 802.3, TIA TR42.7

Performance:

  • Ten second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • 1 billion links reported on LinkWare management software

ProjX™ Management System

Versiv’s ProjX™ System manages jobs from setup to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email. Easy just met efficient.

Taptive™ User Interface

Now you can test across multiple media types and requirements as easy as using a smartphone. Simply, select the job you’re working on, and the large display confirms the test that needs to be performed. Taptive helps you tap into the overall cabling infrastructure faster and more easily.

LinkWare™ Management Software

Project managers have full capabilities to monitor workflow and consolidate test results.

LinkWare pulls data together into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare stats, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.

Applications

  • Data center monitoring and maintenance

Fluke Networks DSX2-5-IE-K1 Specifications

Cable Types
Shielded and Unshielded Pair LAN Cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent Link Adapters Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum Frequency 1000 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds
Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-5000 module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm)
Weight Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32 to 113°F (0 to 45°C)
Storage Temperature -4 to 122°F (-20 to 50°C)
Operating relative humidity 0% to 90%, 32 to 95°F (0 to 35°C)
0% to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories) DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling Without Remote
Range 2600' (800 m)
Resolution 1' (0.1 m )
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
Length of Twisted Pair Cabling With Remote
Range 490' (150 m)
Resolution 1' (0.1 m)
Accuracy ± (0.3 m + 2 %)
Propagation Delay Without Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Propagation Delay With Remote
Range 750 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Click here for complete specifications on the Fluke Networks DSX2-5-IE-K1

What's included with the Fluke Networks DSX2-5-IE-K1

  • Versiv Mainframe and Remote
  • Statement of Calibration
  • 2 x Copper CableAnalyzer Modules
  • Channel Adapters
  • M12X Adapters
  • M12D Adapters
  • Reference Module
  • 2 x Headsets
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • USB Interface Cable
  • 2 x AC Chargers
  • Intergrated Wi-Fi
  • Carrying Case
  • Getting Started Guide

Ask a question about Fluke Networks DSX2-5-IE-K1 CableAnalyzer Industrial Ethernet Copper Certifier Kit, versiv 2

Customer Reviews for the Fluke Networks DSX2-5-IE-K1

Fluke Networks DSX2-5-IE-K1 Offers

The DSX-5000 CableAnalyzer improves the efficiency of copper certification with unmatched speed for testing Cat 6A and Class FAwhile meeting draft IEC Level V – the most stringent accuracy requirement. The ProjX Management System helps ensure jobs are done correctly the first time and helps tracks progress from set-up to systems acceptance. Versiv platform supports modules for fiber testing (Both OLTS and OTDR) and Wi-Fi Analysis and Ethernet troubleshooting. The platform is easily upgradeable to support future standards. Troubleshoot faults faster with the Taptive user interface which graphically displays the source of failures including crosstalk, return loss and shield faults. Analyze test results and create professional test reports using LinkWare™ Management Software.

Fluke Networks' DSX-5000 CableAnalyzer is Intertek (ETL) Verified in accordance with the IEC-61935-1 specifications for accuracy Level IV, and draft accuracy Level V, and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

Unique Features:

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem

Standards:

  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA/EIA-568-C.2
  • Next generation balance drafts – IEEE 802.3, TIA TR42.7

Performance:

  • Ten second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • 1 billion links reported on LinkWare management software

ProjX™ Management System

Versiv’s ProjX™ System manages jobs from setup to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email. Easy just met efficient.

Taptive™ User Interface

Now you can test across multiple media types and requirements as easy as using a smartphone. Simply, select the job you’re working on, and the large display confirms the test that needs to be performed. Taptive helps you tap into the overall cabling infrastructure faster and more easily.

LinkWare™ Management Software

Project managers have full capabilities to monitor workflow and consolidate test results.

LinkWare pulls data together into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare stats, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.

Applications

  • Data center monitoring and maintenance

Fluke Networks DSX2-5-IE-K1 Specifications

Cable Types
Shielded and Unshielded Pair LAN Cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent Link Adapters Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum Frequency 1000 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds
Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-5000 module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm)
Weight Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32 to 113°F (0 to 45°C)
Storage Temperature -4 to 122°F (-20 to 50°C)
Operating relative humidity 0% to 90%, 32 to 95°F (0 to 35°C)
0% to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories) DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling Without Remote
Range 2600' (800 m)
Resolution 1' (0.1 m )
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
Length of Twisted Pair Cabling With Remote
Range 490' (150 m)
Resolution 1' (0.1 m)
Accuracy ± (0.3 m + 2 %)
Propagation Delay Without Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Propagation Delay With Remote
Range 750 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Click here for complete specifications on the Fluke Networks DSX2-5-IE-K1

What's included with the Fluke Networks DSX2-5-IE-K1

  • Versiv Mainframe and Remote
  • Statement of Calibration
  • 2 x Copper CableAnalyzer Modules
  • Channel Adapters
  • M12X Adapters
  • M12D Adapters
  • Reference Module
  • 2 x Headsets
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • USB Interface Cable
  • 2 x AC Chargers
  • Intergrated Wi-Fi
  • Carrying Case
  • Getting Started Guide

Ask a question about Fluke Networks DSX2-5-IE-K1 CableAnalyzer Industrial Ethernet Copper Certifier Kit, versiv 2

Customer Reviews for the Fluke Networks DSX2-5-IE-K1

More Fluke Networks Products