Fluke FLK-TI300 9HZ Specifications

Fluke Ti200 Fluke Ti300 Fluke Ti400
Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F) -20 °C to +650 °C (-4 °F to +1202 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (by number and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type Focal Plane Array, uncooled microbolometer, 320 x 240 pixels Focal Plane Array, uncooled microbolometer, 240 X 180 pixels Focal Plane Array, uncooled microbolometer, 200 X 150 pixels
Thermal sensitivity (NETD) < 0.05 °C at 30 °C target temp (50 mK) < 0.075 °C at 30 °C target temp (75 mK)
Total pixels 76,800 43,200 30,000
Infrared spectral band 7.5 ?m to 14 ?m (long wave)
Visual (visible light) camera Industrial performance 5.0 megapixel
Standard infrared lens type
Field of view 24 ° x 17 °
Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad
Minimum focus distance 15 cm (approx. 6 in)
Optional telephoto infrared lens type
Field of view 12 ° x 9 °
Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad
Minimum focus distance 45 cm (approx. 18 in)
Optional wide-angle infrared lens type
Field of view 46 ° x 34 °
Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad
Minimum focus distance 15 cm (approx. 6 in)
Focus mechanism
LaserSharp™ Auto Focus System Yes
Advanced Manual Focus Yes
Image presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
IR-Fusion® information
Picture-In-Picture (PIP) Yes
Full screen infrared Yes
AutoBlend™ mode Yes
Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
Image capture and data storage
Image capture, review, save mechanism One-handed image capture, review, and save capability
Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
Other time-saving and productivity features
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes™ Yes
Wi-Fi connectivity Yes, to PC, iPhone® , iPad® and WiFi to LAN*
Text annotation* Yes
Video recording* Standard and Radiometric
Streaming Video Via USB to PC and HDMI to HDMI compatible screen
CNX™ Wireless System* Yes*
Cardinal Compass* Yes*
Auto capture (temperature and interval)* Yes*
Remote control and operation (for special and advanced applications) Yes No No
General Specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image
Expandable-contractable Measurement Box with MIN-AVG-MAX temp
Color alarms
User selectable backlight setting
Graphical information display preference
Software SmartView® and SmartView Mobile App - full analysis and reporting software included
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power saving User selectable sleep and power off modes
Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Subpart B Class B
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
Weight (battery included) 1.04 Kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
Click here for complete specifications on the Fluke FLK-TI300 9HZ

What's included with the Fluke FLK-TI300 9HZ

  • Fluke Ti300 9hz Thermal Imager
  • Click on a category to view a selection of compatible accessories with the Fluke Ti300 9hz Thermal Imager.

    Fluke LENS/25MAC2 Optional Thermal Imaging Lens, 25 µm Macro LENS/25MAC2
    Optional macro lens for the TI200/300/400 thermal imaging cameras.




    Fluke LENS/4XTELE2 Optional Thermal Imaging Lens, 4x Telephoto LENS/4XTELE2
    Optional 4X Telephoto Lens for the TI200/300/400 Thermal Imaging Cameras.




    Customer Reviews for the Fluke FLK-TI300 9HZ

    Ask a question about Fluke Ti300 9hz Thermal Imager

    Fluke FLK-TI300 9HZ Specifications

    Fluke Ti200 Fluke Ti300 Fluke Ti400
    Temperature
    Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F) -20 °C to +650 °C (-4 °F to +1202 °F)
    Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
    On-screen emissivity correction Yes (by number and table)
    On-screen reflected background temperature compensation Yes
    On-screen transmission correction Yes
    Imaging performance
    Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
    Detector type Focal Plane Array, uncooled microbolometer, 320 x 240 pixels Focal Plane Array, uncooled microbolometer, 240 X 180 pixels Focal Plane Array, uncooled microbolometer, 200 X 150 pixels
    Thermal sensitivity (NETD) < 0.05 °C at 30 °C target temp (50 mK) < 0.075 °C at 30 °C target temp (75 mK)
    Total pixels 76,800 43,200 30,000
    Infrared spectral band 7.5 ?m to 14 ?m (long wave)
    Visual (visible light) camera Industrial performance 5.0 megapixel
    Standard infrared lens type
    Field of view 24 ° x 17 °
    Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad
    Minimum focus distance 15 cm (approx. 6 in)
    Optional telephoto infrared lens type
    Field of view 12 ° x 9 °
    Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad
    Minimum focus distance 45 cm (approx. 18 in)
    Optional wide-angle infrared lens type
    Field of view 46 ° x 34 °
    Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad
    Minimum focus distance 15 cm (approx. 6 in)
    Focus mechanism
    LaserSharp™ Auto Focus System Yes
    Advanced Manual Focus Yes
    Image presentation
    Palettes
    Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
    Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
    Level and span Smooth auto-scaling and manual scaling of level and span
    Fast auto toggle between manual and auto modes Yes
    Fast auto-rescale in manual mode Yes
    Minimum span (in manual mode) 2.0 °C (3.6 °F)
    Minimum span (in auto mode) 3.0 °C (5.4 °F)
    IR-Fusion® information
    Picture-In-Picture (PIP) Yes
    Full screen infrared Yes
    AutoBlend™ mode Yes
    Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
    Image capture and data storage
    Image capture, review, save mechanism One-handed image capture, review, and save capability
    Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
    File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
    No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
    Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
    Memory review Thumbnail view navigation and review selection
    Other time-saving and productivity features
    Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
    IR-PhotoNotes™ Yes
    Wi-Fi connectivity Yes, to PC, iPhone® , iPad® and WiFi to LAN*
    Text annotation* Yes
    Video recording* Standard and Radiometric
    Streaming Video Via USB to PC and HDMI to HDMI compatible screen
    CNX™ Wireless System* Yes*
    Cardinal Compass* Yes*
    Auto capture (temperature and interval)* Yes*
    Remote control and operation (for special and advanced applications) Yes No No
    General Specifications
    Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
    Relative humidity 10 % to 95 % non-condensing
    Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
    Controls and adjustments User selectable temperature scale (°C/°F)
    Language selection
    Time/Date set
    Emissivity selection
    Reflected background temperature compensation
    Transmission correction
    User selectable hot spot and cold spot, and center point on the image
    Expandable-contractable Measurement Box with MIN-AVG-MAX temp
    Color alarms
    User selectable backlight setting
    Graphical information display preference
    Software SmartView® and SmartView Mobile App - full analysis and reporting software included
    Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
    Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
    Battery charge time 2.5 hours to full charge
    AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models
    AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
    Power saving User selectable sleep and power off modes
    Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
    Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
    C Tick IEC/EN 61326-1
    US FCC CFR 47, Part 15 Subpart B Class B
    Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
    Shock 25 g, IEC 68-2-29
    Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
    Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
    Weight (battery included) 1.04 Kg (2.3 lb)
    Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
    Warranty Two-years (standard), extended warranties are available
    Recommended calibration cycle Two-years (assumes normal operation and normal aging)
    Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
    Click here for complete specifications on the Fluke FLK-TI300 9HZ

    What's included with the Fluke FLK-TI300 9HZ

  • Fluke Ti300 9hz Thermal Imager
  • Click on a category to view a selection of compatible accessories with the Fluke Ti300 9hz Thermal Imager.

    Fluke LENS/25MAC2 Optional Thermal Imaging Lens, 25 µm Macro LENS/25MAC2
    Optional macro lens for the TI200/300/400 thermal imaging cameras.




    Fluke LENS/4XTELE2 Optional Thermal Imaging Lens, 4x Telephoto LENS/4XTELE2
    Optional 4X Telephoto Lens for the TI200/300/400 Thermal Imaging Cameras.




    Ask a question about Fluke Ti300 9hz Thermal Imager

    Customer Reviews for the Fluke FLK-TI300 9HZ

    More Fluke Products

    Calibration Lab