Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Model: 4181 | Order No: 4181-156 | UPC: 095969441124

Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Model: 4181 | Order No: 4181-156 | UPC: 095969441124

Increasing your IR temperature measurement accuracy has never been easier with this precision infrared calibrator. Intuitive and easy-to-use, the calibrator provides accuracy and traceability for infrared thermometers and thermal imagers and reaches temperatures from 95 to 932°F (35 to 500°C).

Increasing your IR temperature measurement accuracy has never been easier with this precision infrared calibrator. Intuitive and easy-to-use, the calibrator provides accuracy and traceability for infrared thermometers and thermal imagers and reaches temperatures from 95 to 932°F (35 to 500°C).

Your Price $9851.00 USD
Availability 4 to 5 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 4181 Infrared Temperature Calibrator

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 4181 Infrared Temperature Calibrator

Recommended Accessories


Fluke 4181-156 Offers

Coming from one of the world’s most trusted temperature calibration laboratories, this precision infrared calibrator is incomparable, and the perfect solution for any infrared thermometer or thermal imager within its temperature range. Reliable with accuracies as good as ±32.6°F (0.35 °C), the calibrator can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Features

  • Large target Dimensions of 152mm (6") captures "peripheral vision" of infrared thermometers and minimizes Dimensions of source effect errors
  • Compensates for errors caused by individual infrared thermometer emissivity settings
  • Sample calibration procedures for Fluke and Raytek thermometers are built right in
  • Accuracy as good as ±0.35°C
  • Test Uncertainty Ratios (TUR) as good as 4:1
  • Excellent stability and uniformity
  • Reaches temperature setpoint quickly
  • Intuitive, easy-to-read display that indicates when temperature is stable

Fluke 4181 Specifications

Temperature Range (at 23°C ambient, 0.95 emissivity) 95 to 932°F (35 to 500°C)
Power 115 V AC (±10%), 50/60 Hz, 250 W 230 V ac (±10%), 50/60 Hz, 1100 W
Display Accuracy ±0.35°C at 35°C, ±0.50°C at 100°C, ±0.70°C at 200°C, ±1.20°C at 350°C, ±1.60°C at 500°C
Stabilility ±0.05°C at 35°C, ±0.20°C at 200°C, ±0.40°C at 500°C
Uniformity (5" (12.7 cm) diameter of center of target) ±0.10°C at 35°C, ±0.50°C at 200°C, ±1.00°C at 500°C
Uniformity (2" (5.08 cm) diameter of center of target) ± 0.10°C at 35°C, ±0.25°C at 200°C, ±0.50°C at 500°C
Heating Time 20 min: 95 to 932°F (35 to 500°C)
Cooling Time 100 min: 932 to 95°F (500 to 35°C)
40 min: 932 to 212° (500 to 100°C)
Stabilization Time 10 minutes
Nominal Emissivity 0.95
Thermometer Emissivity Compensation Range 0.9 to 1.0
Ambient Temperature 5 to 35°C (41 to 95⪚F)
Ambient Relative Humidity maximum 80% for temperature <31°C, decreasing linearly to 50% at 40°C
Fuses 115 V: F 10 A, 250 V
230 V: F 5 A, 250 V
Altitude <6561' (2000 m)
Target Diameter 6" (152.4 mm)
Computer Interface RS-232
Dimensions 356 x 241 x 216 mm (14 x 9.5 x 8.5 in)
Weight 21 lbs (9.5 kg)
Safety IEC 61010-1: Overvoltage Category II, Pollution Degree 2 IEC 61010-2-010
Click here for complete specifications on the Fluke 4181

What's included with the Fluke 4181

  • Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Click on a category to view a selection of compatible accessories with the Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke 4180-DCAS Carrying Case for Infrared Calibrator 4180-DCAS
Wheeled carrying case is lightweight and features recessed steel handles and latches with foam lined for impact protection.




Fluke 4180-APRT Aperture 50mm 4180-APRT
Many radiometers require the use of an aperture to reduce the effect of scatter. This is a simple-to-use, 2-inch non-water cooled aperture designed for use with the 4180 or 4181 Precision Infrared Calibrators.




Ask a question about Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Customer Reviews for the Fluke 4181

Fluke 4181-156 Offers

Coming from one of the world’s most trusted temperature calibration laboratories, this precision infrared calibrator is incomparable, and the perfect solution for any infrared thermometer or thermal imager within its temperature range. Reliable with accuracies as good as ±32.6°F (0.35 °C), the calibrator can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Features

  • Large target Dimensions of 152mm (6") captures "peripheral vision" of infrared thermometers and minimizes Dimensions of source effect errors
  • Compensates for errors caused by individual infrared thermometer emissivity settings
  • Sample calibration procedures for Fluke and Raytek thermometers are built right in
  • Accuracy as good as ±0.35°C
  • Test Uncertainty Ratios (TUR) as good as 4:1
  • Excellent stability and uniformity
  • Reaches temperature setpoint quickly
  • Intuitive, easy-to-read display that indicates when temperature is stable

Fluke 4181 Specifications

Temperature Range (at 23°C ambient, 0.95 emissivity) 95 to 932°F (35 to 500°C)
Power 115 V AC (±10%), 50/60 Hz, 250 W 230 V ac (±10%), 50/60 Hz, 1100 W
Display Accuracy ±0.35°C at 35°C, ±0.50°C at 100°C, ±0.70°C at 200°C, ±1.20°C at 350°C, ±1.60°C at 500°C
Stabilility ±0.05°C at 35°C, ±0.20°C at 200°C, ±0.40°C at 500°C
Uniformity (5" (12.7 cm) diameter of center of target) ±0.10°C at 35°C, ±0.50°C at 200°C, ±1.00°C at 500°C
Uniformity (2" (5.08 cm) diameter of center of target) ± 0.10°C at 35°C, ±0.25°C at 200°C, ±0.50°C at 500°C
Heating Time 20 min: 95 to 932°F (35 to 500°C)
Cooling Time 100 min: 932 to 95°F (500 to 35°C)
40 min: 932 to 212° (500 to 100°C)
Stabilization Time 10 minutes
Nominal Emissivity 0.95
Thermometer Emissivity Compensation Range 0.9 to 1.0
Ambient Temperature 5 to 35°C (41 to 95⪚F)
Ambient Relative Humidity maximum 80% for temperature <31°C, decreasing linearly to 50% at 40°C
Fuses 115 V: F 10 A, 250 V
230 V: F 5 A, 250 V
Altitude <6561' (2000 m)
Target Diameter 6" (152.4 mm)
Computer Interface RS-232
Dimensions 356 x 241 x 216 mm (14 x 9.5 x 8.5 in)
Weight 21 lbs (9.5 kg)
Safety IEC 61010-1: Overvoltage Category II, Pollution Degree 2 IEC 61010-2-010
Click here for complete specifications on the Fluke 4181

What's included with the Fluke 4181

  • Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Click on a category to view a selection of compatible accessories with the Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke 4180-DCAS Carrying Case for Infrared Calibrator 4180-DCAS
Wheeled carrying case is lightweight and features recessed steel handles and latches with foam lined for impact protection.




Fluke 4180-APRT Aperture 50mm 4180-APRT
Many radiometers require the use of an aperture to reduce the effect of scatter. This is a simple-to-use, 2-inch non-water cooled aperture designed for use with the 4180 or 4181 Precision Infrared Calibrators.




Ask a question about Fluke 4181 Infrared Temperature Calibrator, HART, 95 to 932°F

Customer Reviews for the Fluke 4181

More Fluke Products

Calibration Lab