Fluke 1623 Offers

  • Adjustable stroke length can be set to limit the pressure per stroke
  • 1/4 in NPT male to 1/4 in BSP female
  • 1 meter of hose
  • (2) 1/8 in NPT male quick connects
  • 1/8 NPT female to 1/4 in BSP female
  • Seal Kit
  • Instruction sheet

Specifications:

RA 3-pole ground resistance measurement (IEC 1557-5)

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(2% of reading + 3 digit)
  • Operating Error: ±(5% of reading +3 digit)

RA 4-pole ground resistance measurement (IEC 1557-5)

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(2% of reading + 3 digit)
  • Operating Error: ±(5% of reading +3 digit)

RA 3-pole ground resistance measurement with current clamp

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

RA 4-pole selective ground resistance measurement with current clamp

  • Measuring Voltage: Vm = 48Vac
  • Short Circuit Current: >50 mA
  • Measure Frequency: 128Hz
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

Stakeless ground loop measurement

  • Measuring Voltage: Vm = 48Vac
  • Measure Frequency: 128Hz (125 Hz on request)
  • Noise Current (lext): Max. let = 10A(ac) (RA <20Ω)
  • Resolution: 0.001Ω to 10Ω
  • Measuring Range: 0.001Ω to 19.99kΩ
  • Intrinsic Error: ±(7% of reading + 3 digit)
  • Operating Error: ±(10% of reading +3 digit)

General Specifications

  • Display: 1999 digit LCD – display with special symbols, digit height 25 mm, fluorescent backlight
  • Dimensions length: 8.7 in (220 mm), width 4.8 in (122 mm), depth 3.5 in (89 mm)
  • Weight: 1.03 lb (467 g)
  • Material Wetted materials: aluminum, silicon, neoprene, stainless steel, Buna-N

What's included with the Fluke 1623

  • Fluke 1623 Basic GEO Earth Ground Tester
  • Customer Reviews for the Fluke 1623

    Ask a question about Fluke 1623 Basic GEO Earth Ground Tester

    Fluke 1623 Offers

    • Adjustable stroke length can be set to limit the pressure per stroke
    • 1/4 in NPT male to 1/4 in BSP female
    • 1 meter of hose
    • (2) 1/8 in NPT male quick connects
    • 1/8 NPT female to 1/4 in BSP female
    • Seal Kit
    • Instruction sheet

    Specifications:

    RA 3-pole ground resistance measurement (IEC 1557-5)

    • Measuring Voltage: Vm = 48Vac
    • Short Circuit Current: >50 mA
    • Measure Frequency: 128Hz
    • Resolution: 0.001Ω to 10Ω
    • Measuring Range: 0.001Ω to 19.99kΩ
    • Intrinsic Error: ±(2% of reading + 3 digit)
    • Operating Error: ±(5% of reading +3 digit)

    RA 4-pole ground resistance measurement (IEC 1557-5)

    • Measuring Voltage: Vm = 48Vac
    • Short Circuit Current: >50 mA
    • Measure Frequency: 128Hz
    • Resolution: 0.001Ω to 10Ω
    • Measuring Range: 0.001Ω to 19.99kΩ
    • Intrinsic Error: ±(2% of reading + 3 digit)
    • Operating Error: ±(5% of reading +3 digit)

    RA 3-pole ground resistance measurement with current clamp

    • Measuring Voltage: Vm = 48Vac
    • Short Circuit Current: >50 mA
    • Measure Frequency: 128Hz
    • Resolution: 0.001Ω to 10Ω
    • Measuring Range: 0.001Ω to 19.99kΩ
    • Intrinsic Error: ±(7% of reading + 3 digit)
    • Operating Error: ±(10% of reading +3 digit)

    RA 4-pole selective ground resistance measurement with current clamp

    • Measuring Voltage: Vm = 48Vac
    • Short Circuit Current: >50 mA
    • Measure Frequency: 128Hz
    • Resolution: 0.001Ω to 10Ω
    • Measuring Range: 0.001Ω to 19.99kΩ
    • Intrinsic Error: ±(7% of reading + 3 digit)
    • Operating Error: ±(10% of reading +3 digit)

    Stakeless ground loop measurement

    • Measuring Voltage: Vm = 48Vac
    • Measure Frequency: 128Hz (125 Hz on request)
    • Noise Current (lext): Max. let = 10A(ac) (RA <20Ω)
    • Resolution: 0.001Ω to 10Ω
    • Measuring Range: 0.001Ω to 19.99kΩ
    • Intrinsic Error: ±(7% of reading + 3 digit)
    • Operating Error: ±(10% of reading +3 digit)

    General Specifications

    • Display: 1999 digit LCD – display with special symbols, digit height 25 mm, fluorescent backlight
    • Dimensions length: 8.7 in (220 mm), width 4.8 in (122 mm), depth 3.5 in (89 mm)
    • Weight: 1.03 lb (467 g)
    • Material Wetted materials: aluminum, silicon, neoprene, stainless steel, Buna-N