Delivering AC/DC voltage measurements up to 600 V and current up to 10 A, this palm-sized digital multimeter features a CAT III safety rating for reliable electrical testing. It also supports resistance and continuity measurements for detecting broken wires, along with a data hold function for safe operation. Ideal for field technicians performing everyday electrical diagnostics.
Delivering AC/DC voltage measurements up to 600 V and current up to 10 A, this palm-sized digital multimeter features a CAT III safety rating for reliable electrical testing. It also supports resistance and continuity measurements for detecting broken wires, along with a data hold function for safe operation. Ideal for field technicians performing everyday electrical diagnostics.
The Fluke 106 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 106 delivers reliable measurements time after time.
Features
Applications
| Function | |
| AC volts (40 Hz to 500 Hz)1 | Range: 6.000 V/Resolution: 0.001 V/Accuracy: 1.0% + 3 Range: 60.00 V/Resolution: 0.01 V/Accuracy: 1.0% + 3 Range: 600.0 V/Resolution: 0.1 V/Accuracy: 1.0% + 3/ |
| DC volts | Range: 6.000 V/Resolution: 0.001 V/Accuracy: 0.5% + 3 Range: 60.00 V/Resolution: 0.01 V/Accuracy: 0.5% + 3 Range: 600.0 V/Resolution: 0.1 V/Accuracy: 0.5% + 3 |
| AC millivolts | Range: 600.0 mV/Resolution: 0.1 mV/Accuracy: 3.0% + 3 |
| Resistance (ohms) | Range: 400.0 Ω/Resolution: 0.1 Ω/Accuracy: 0.5% + 3 Range: 4.000 kΩ/Resolution: 0.001 kΩ/Accuracy: 0.5% + 2 Range: 40.00 kΩ/Resolution: 0.01 kΩ/Accuracy: 0.5% + 2 Range: 400.0 kΩ/Resolution: 0.1 kΩ/Accuracy: 0.5% + 2 Range: 4.000 MΩ/Resolution: 0.001 MΩ/Accuracy: 0.5% + 2 Range: 40.00 MΩ/Resolution: 0.01 MΩ/Accuracy: 1.5% + 3 |
| Capacitance2 | Range: 50.00 nF/Resolution: 0.01 nF/Accuracy: 2% + 5/ Range: 500.0 nF/Resolution: 0.1 nF/Accuracy: 2% + 5/ Range: 5.000 µF/Resolution: 0.001 µF/Accuracy: 5% + 5/ Range: 50.00 µF/Resolution: 0.01 µF/Accuracy: 5% + 5 Range: 500.0 µF/Resolution: 0.1 µF/Accuracy: 5% + 5 Range: 1000 µF/Resolution: 1 µF/Accuracy: 5% + 5 |
| AC current (40 Hz to 200 Hz) | Range: 4.000 A/Resolution: 0.001 A/Accuracy: 1.5% + 3 Range: 10.00 A/Resolution: 0.01 A/Accuracy: 1.5% + 3 |
| DC current | Range: 4.000 A/Resolution: 0.001 A/Accuracy: 1.5% + 3 Range: 10.00 A/Resolution: 0.01 A/Accuracy: 1.5% + 3 |
| Notes* | Accuracy is specified for 1 year after calibration, at operating temperatures of 64 to 82°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) 1 All AC are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2 Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). |
| Electrical | |
| AC volts Functions | Overload protection: 600 V1 Input impedance (nominal): > 10 MΩ/< 100 pF2 Common mode rejection ratio: > 60 dB at dc, 50 Hz or 60 Hz |
| AC millivolts Functions | Overload protection: 600 mV1 Input impedance (nominal): > 1 M/< 100 pF Common mode rejection ratio: > 80 dB at 50 Hz or 60 Hz |
| DC volts Functions | Overload protection: 600 V2 Input impedance (nominal): > > 10 MΩ/< 100 pF Common mode rejection ratio: > 100 dB at dc, 50 Hz or 60 Hz Normal mode rejection ratio: > 45 dB at 50 Hz or 60 Hz |
| Notes* | 1 6 x 105 V Hz Max 2 For mV (AC), input impedance is approximately 1 MΩ |
| General | |
| Maximum voltage between any terminal and earth ground | 600 V |
| Display | LCD 6000 counts, updates 3/sec |
| Altitude | Operating: 6561' (2000 m) Storage: 39370' (12,000 m) |
| Temperature coefficient | 0.1 x (specified accuracy)/°F (< 64.4°F (18°C) or > 82.4°F (28°C)) |
| Fuse protection for current inputs | 11 A, 1000 V fast fuse, Fluke specified part only |
| IP rating | IEC 60529: IP40 |
| Safety | IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT III 600 V, 10 A |
| Electromagnetic | Environment: IEC 61326-1: Portable Compatibility: Korea only; Class A equipment (industrial broadcasting and communication equipment) |
| Environmentals Condition | Operating temperature: 32 to 104°F (0 to 40°C) Storage temperature: -22 to 140°F (-30 to 60°C) Relative humidity (operating): Non condensing when < 50°F (10°C); ≤ 90% at 50 to 86°F (10 to 30°C); ≤ 75% at 86 to 104°F (30 to 40°C) Operating humidity (40 MΩ range): ≤ 80% at 50 to 86°F (10 to 30°C); ≤ 70% at 86 to 104°F (30 to 40°C) |
| Power | Tyepe: 2 x AAA, IEC LR03 Life: 200 hours minimum |
| Dimensions | 1.6 x 2.7 x 1.1" (142 x 69 x 28 mm) |
| Weight | 7 oz (200 g) |
Click on a category to view a selection of compatible accessories with the Fluke 106 Digital Multimeter, AC/DC, 600 V, palm-sized.
| Function | |
| AC volts (40 Hz to 500 Hz)1 | Range: 6.000 V/Resolution: 0.001 V/Accuracy: 1.0% + 3 Range: 60.00 V/Resolution: 0.01 V/Accuracy: 1.0% + 3 Range: 600.0 V/Resolution: 0.1 V/Accuracy: 1.0% + 3/ |
| DC volts | Range: 6.000 V/Resolution: 0.001 V/Accuracy: 0.5% + 3 Range: 60.00 V/Resolution: 0.01 V/Accuracy: 0.5% + 3 Range: 600.0 V/Resolution: 0.1 V/Accuracy: 0.5% + 3 |
| AC millivolts | Range: 600.0 mV/Resolution: 0.1 mV/Accuracy: 3.0% + 3 |
| Resistance (ohms) | Range: 400.0 Ω/Resolution: 0.1 Ω/Accuracy: 0.5% + 3 Range: 4.000 kΩ/Resolution: 0.001 kΩ/Accuracy: 0.5% + 2 Range: 40.00 kΩ/Resolution: 0.01 kΩ/Accuracy: 0.5% + 2 Range: 400.0 kΩ/Resolution: 0.1 kΩ/Accuracy: 0.5% + 2 Range: 4.000 MΩ/Resolution: 0.001 MΩ/Accuracy: 0.5% + 2 Range: 40.00 MΩ/Resolution: 0.01 MΩ/Accuracy: 1.5% + 3 |
| Capacitance2 | Range: 50.00 nF/Resolution: 0.01 nF/Accuracy: 2% + 5/ Range: 500.0 nF/Resolution: 0.1 nF/Accuracy: 2% + 5/ Range: 5.000 µF/Resolution: 0.001 µF/Accuracy: 5% + 5/ Range: 50.00 µF/Resolution: 0.01 µF/Accuracy: 5% + 5 Range: 500.0 µF/Resolution: 0.1 µF/Accuracy: 5% + 5 Range: 1000 µF/Resolution: 1 µF/Accuracy: 5% + 5 |
| AC current (40 Hz to 200 Hz) | Range: 4.000 A/Resolution: 0.001 A/Accuracy: 1.5% + 3 Range: 10.00 A/Resolution: 0.01 A/Accuracy: 1.5% + 3 |
| DC current | Range: 4.000 A/Resolution: 0.001 A/Accuracy: 1.5% + 3 Range: 10.00 A/Resolution: 0.01 A/Accuracy: 1.5% + 3 |
| Notes* | Accuracy is specified for 1 year after calibration, at operating temperatures of 64 to 82°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) 1 All AC are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2 Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). |
| Electrical | |
| AC volts Functions | Overload protection: 600 V1 Input impedance (nominal): > 10 MΩ/< 100 pF2 Common mode rejection ratio: > 60 dB at dc, 50 Hz or 60 Hz |
| AC millivolts Functions | Overload protection: 600 mV1 Input impedance (nominal): > 1 M/< 100 pF Common mode rejection ratio: > 80 dB at 50 Hz or 60 Hz |
| DC volts Functions | Overload protection: 600 V2 Input impedance (nominal): > > 10 MΩ/< 100 pF Common mode rejection ratio: > 100 dB at dc, 50 Hz or 60 Hz Normal mode rejection ratio: > 45 dB at 50 Hz or 60 Hz |
| Notes* | 1 6 x 105 V Hz Max 2 For mV (AC), input impedance is approximately 1 MΩ |
| General | |
| Maximum voltage between any terminal and earth ground | 600 V |
| Display | LCD 6000 counts, updates 3/sec |
| Altitude | Operating: 6561' (2000 m) Storage: 39370' (12,000 m) |
| Temperature coefficient | 0.1 x (specified accuracy)/°F (< 64.4°F (18°C) or > 82.4°F (28°C)) |
| Fuse protection for current inputs | 11 A, 1000 V fast fuse, Fluke specified part only |
| IP rating | IEC 60529: IP40 |
| Safety | IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT III 600 V, 10 A |
| Electromagnetic | Environment: IEC 61326-1: Portable Compatibility: Korea only; Class A equipment (industrial broadcasting and communication equipment) |
| Environmentals Condition | Operating temperature: 32 to 104°F (0 to 40°C) Storage temperature: -22 to 140°F (-30 to 60°C) Relative humidity (operating): Non condensing when < 50°F (10°C); ≤ 90% at 50 to 86°F (10 to 30°C); ≤ 75% at 86 to 104°F (30 to 40°C) Operating humidity (40 MΩ range): ≤ 80% at 50 to 86°F (10 to 30°C); ≤ 70% at 86 to 104°F (30 to 40°C) |
| Power | Tyepe: 2 x AAA, IEC LR03 Life: 200 hours minimum |
| Dimensions | 1.6 x 2.7 x 1.1" (142 x 69 x 28 mm) |
| Weight | 7 oz (200 g) |
Click on a category to view a selection of compatible accessories with the Fluke 106 Digital Multimeter, AC/DC, 600 V, palm-sized.