FLOMEC G-100-3A-3 GSCPS Series Turbine Flow Meter 3A with magnetic pickup, stainless steel body and tri-clamp, 3-wire, 1"

Model: G-100-3A-3 | Order No: GSCPS-100-3

FLOMEC G-100-3A-3 GSCPS Series Turbine Flow Meter 3A with magnetic pickup, stainless steel body and tri-clamp, 3-wire, 1"

Model: G-100-3A-3 | Order No: GSCPS-100-3

Built to meet the strict 3A Sanitary Standards, this flowmeter is ideal for food and beverage applications. Featuring a stainless steel body, 1.5" (3.81 cm) tri-clamp connections, and a 3-wire magnetic pickup, it complies with Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements.

Built to meet the strict 3A Sanitary Standards, this flowmeter is ideal for food and beverage applications. Featuring a stainless steel body, 1.5" (3.81 cm) tri-clamp connections, and a 3-wire magnetic pickup, it complies with Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements.

Sale Price $2443.50 USD
Regular Price $3258.00 USD
Availability 2 to 3 Weeks
Quantity

FLOMEC G-100-3A-3 Offers

The GSCPS Series High Precision Meter is the most accurate of all the FLOMEC® Turbine Meters. In addition, this meter meets the strict 3A Sanitary Standards for any food and beverage application.

The GSCPS turbine meter's robust design provides reliable performance while delivering economical operating costs. The internals of the 3A meter are machined and polished to meet 3A self-draining and cleaning requirements (Ra 32). Parts are easily replaceable making lifetime maintenance of the turbine meter a preferred choice.

Features

  • CIP (clean in place) | SIP (steam in place) | COP (clean out of place)
  • Proven turbine design that provides the best total operating cost
  • 2-Wire Magnetic Pickup with 10' (3 m) of Cable (Sine Wave Pulse)
  • Meets Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements to allow for any sanitary procedure that work best for plant managers
  • Internal parts are simple to replace for easy maintenance
  • +/- 0.5% accuracy of reading and +/- 0.1% repeatability providing reliable, accurate flow measurement
  • Expansive working temperature of -100 to 250°F (-73 to 121°C) to accommodate various stages of food and beverage processes°
  • Multiple blind pulse out options available for connection to a variety of PLC, display equipment, and process control equipment
  • Meets Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements to allow for any sanitary procedure that work best for plant managers
  • Factory installed local Rate and Totalizer display available with digital, analog and flow alarm outputs
  • Turbine capable of 285°F (140°C) temperature up to 1 hour for SIP sanitary procedures
  • Wide temperature range to accommodate various stages of food and beverage processes
  • Turbine capable of 285°F (140°C) temperature up to 1 hour for SIP sanitary procedures
  • 4 to 20 mA analogue output according to flow rate
  • Scaled pulse output according to accumulated total

Applications

  • Batching
  • Milk
  • Brewing
  • Water
  • Food and beverage processing
  • Beer
  • Blending
  • Alcohols
  • Fuel products
  • Filtered Wine
  • Water
  • De-ionized Water
  • Monitoring clean fluids
  • Vinegar
  • Industrial fluids
  • Light Oils
  • Plant process water
  • Juice
  • CIP Solution

FLOMEC G-100-3A-3 Specifications

Flow Range 6.7 to 67 GPM (25-252 L/min)
Flow Range 6.7 to 67 GPM (25 to 252 L/min)
Accuracy (% of Reading) +/- 0.5%
Accuracy (% of Reading) ±0.5%
Technology Turbine
Technology Turbine
Pressure Rating Limited by fitting, clamp size, & temperature
Pressure Rating Limited by fitting, clamp size, & temperature
Operating Temperature -40 to 248°F (-40 to 120°C)
Operating Temperature -100 to 250°F (-73°C to 121°C)
For SIP (up to 1 hour): 285°F (140°C)
Connection Type/Size Tri-Clamp, 1-1/2" (40 mm)
Connection Type/Size Tri-Clamp, 1-1/2" (40 mm)
Pipe Size 1-inch (25 mm)
Pipe Size 1" (2.5 cm)
Meter Housing Material Stainless Steel
Meter Housing Material Stainless Steel
Wetted Materials 300 Series Stainless Steel, 316 Stainless Steel, CD4MCu Stainless Steel, PEEK
Wetted Materials 300 Series Stainless Steel, 316 Stainless Steel, CD4MCu Stainless Steel, PEEK
Warranty 2-yr meter warranty
Approvals CIP/SIP/COP, 3A 28-06
Approvals CIP/SIP/COP, 3A 28-06

What's included with the FLOMEC G-100-3A-3

  • Turbine Flowmeter
  • Turbine Flowmeter
  • Local Digital Display
  • 2-wire magnetic pickup coil with 10' (3 m) shielded cable
  • 2 x Alkaline AAA Batteries
  • Declaration of Conformity
  • Calibration Report
  • Owner's Manual
  • Owners Manuals
  • Two-Year Warranty
  • Two-Year Warranty

Ask a question about FLOMEC G-100-3A-3 GSCPS Series Turbine Flow Meter 3A with magnetic pickup, stainless steel body and tri-clamp, 3-wire, 1"

Customer Reviews for the FLOMEC G-100-3A-3

FLOMEC G-100-3A-3 Offers

The GSCPS Series High Precision Meter is the most accurate of all the FLOMEC® Turbine Meters. In addition, this meter meets the strict 3A Sanitary Standards for any food and beverage application.

The GSCPS turbine meter's robust design provides reliable performance while delivering economical operating costs. The internals of the 3A meter are machined and polished to meet 3A self-draining and cleaning requirements (Ra 32). Parts are easily replaceable making lifetime maintenance of the turbine meter a preferred choice.

Features

  • CIP (clean in place) | SIP (steam in place) | COP (clean out of place)
  • Proven turbine design that provides the best total operating cost
  • 2-Wire Magnetic Pickup with 10' (3 m) of Cable (Sine Wave Pulse)
  • Meets Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements to allow for any sanitary procedure that work best for plant managers
  • Internal parts are simple to replace for easy maintenance
  • +/- 0.5% accuracy of reading and +/- 0.1% repeatability providing reliable, accurate flow measurement
  • Expansive working temperature of -100 to 250°F (-73 to 121°C) to accommodate various stages of food and beverage processes°
  • Multiple blind pulse out options available for connection to a variety of PLC, display equipment, and process control equipment
  • Meets Clean in Place (CIP), Steam in Place (SIP), and Clean Out of Place (COP) requirements to allow for any sanitary procedure that work best for plant managers
  • Factory installed local Rate and Totalizer display available with digital, analog and flow alarm outputs
  • Turbine capable of 285°F (140°C) temperature up to 1 hour for SIP sanitary procedures
  • Wide temperature range to accommodate various stages of food and beverage processes
  • Turbine capable of 285°F (140°C) temperature up to 1 hour for SIP sanitary procedures
  • 4 to 20 mA analogue output according to flow rate
  • Scaled pulse output according to accumulated total

Applications

  • Batching
  • Milk
  • Brewing
  • Water
  • Food and beverage processing
  • Beer
  • Blending
  • Alcohols
  • Fuel products
  • Filtered Wine
  • Water
  • De-ionized Water
  • Monitoring clean fluids
  • Vinegar
  • Industrial fluids
  • Light Oils
  • Plant process water
  • Juice
  • CIP Solution

FLOMEC G-100-3A-3 Specifications

Flow Range 6.7 to 67 GPM (25-252 L/min)
Flow Range 6.7 to 67 GPM (25 to 252 L/min)
Accuracy (% of Reading) +/- 0.5%
Accuracy (% of Reading) ±0.5%
Technology Turbine
Technology Turbine
Pressure Rating Limited by fitting, clamp size, & temperature
Pressure Rating Limited by fitting, clamp size, & temperature
Operating Temperature -40 to 248°F (-40 to 120°C)
Operating Temperature -100 to 250°F (-73°C to 121°C)
For SIP (up to 1 hour): 285°F (140°C)
Connection Type/Size Tri-Clamp, 1-1/2" (40 mm)
Connection Type/Size Tri-Clamp, 1-1/2" (40 mm)
Pipe Size 1-inch (25 mm)
Pipe Size 1" (2.5 cm)
Meter Housing Material Stainless Steel
Meter Housing Material Stainless Steel
Wetted Materials 300 Series Stainless Steel, 316 Stainless Steel, CD4MCu Stainless Steel, PEEK
Wetted Materials 300 Series Stainless Steel, 316 Stainless Steel, CD4MCu Stainless Steel, PEEK
Warranty 2-yr meter warranty
Approvals CIP/SIP/COP, 3A 28-06
Approvals CIP/SIP/COP, 3A 28-06

What's included with the FLOMEC G-100-3A-3

  • Turbine Flowmeter
  • Turbine Flowmeter
  • Local Digital Display
  • 2-wire magnetic pickup coil with 10' (3 m) shielded cable
  • 2 x Alkaline AAA Batteries
  • Declaration of Conformity
  • Calibration Report
  • Owner's Manual
  • Owners Manuals
  • Two-Year Warranty
  • Two-Year Warranty

Ask a question about FLOMEC G-100-3A-3 GSCPS Series Turbine Flow Meter 3A with magnetic pickup, stainless steel body and tri-clamp, 3-wire, 1"

Customer Reviews for the FLOMEC G-100-3A-3

More FLOMEC Products

Calibration Lab