FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720

Model: Si2-LD No WiFi | Order No: T912635

FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720

Model: Si2-LD No WiFi | Order No: T912635

Designed for pressurized leak detection and mechanical fault detection, this industrial acoustic imaging camera (Non-Wi-Fi model) detects, locates, and measures compressed air and gas leaks. In addition, this camera features built-in measurement and cost analysis for industrial gases such as ammonia, hydrogen, CO2, methane, helium, and argon.

Designed for pressurized leak detection and mechanical fault detection, this industrial acoustic imaging camera (Non-Wi-Fi model) detects, locates, and measures compressed air and gas leaks. In addition, this camera features built-in measurement and cost analysis for industrial gases such as ammonia, hydrogen, CO2, methane, helium, and argon.

Your Price $19849.00 USD
Availability 2 to 3 Weeks
Quantity

Recommended Accessories


FLIR Si2-LD No WiFi Offers

Work with one-handed operations with this industrial acoustic imaging camera that features automatic tuning, 8x zoom, and a 12 MP digital camera. In addition, simplify finding critical mechanical issues, such as bearing faults with this camera's mechanical fault mode, automatic selection, and optimization of filters.

Features

  • Detects, locates, and measures compressed air and gas leaks; including bearing fault detection, from up to 656' (200 m) away
  • Built-in measurement and cost analysis for industrial gases including ammonia, hydrogen, CO2, methane, helium, and argon
  • One-handed operation with automatic tuning, 8x zoom, and a 12 MP digital camera
  • Mechanical fault mode, automatic selection, and optimization of filters simplifies finding critical mechanical issues, such as bearing faults
  • Fleet management functionality for efficient tool usage and maintenance across large-scale operations
  • Intuitive, light weight, one handed operation requiring minimal training
  • The highest performance acoustic imager available
  • Bearing assessment
  • Provides a greater return on investment for ultrasound inspection because the ease of use does not require experienced, trained technicians to get meaningful results
  • MECH mode camera operation allows quick detection and measurement of bearing and other mechanical issues that can lead to costly production disruption or safety hazards (three metrics provided for mechanical fault measurement)
  • Industrial gas quantification provides leak detection, leak rate and cost quantification for compressed air, methane, natural gas, ammonia, hydrogen, helium, and argon to find and prioritize repairs, and maximize return on investment
  • Lights can make a big difference: This camera features dual LED lamps to illuminate nearby dark areas

Applications

  • Detecting and quantifying leaks in manufacturing, production, and assembly applications; in all applications using compressed air
  • Early leak detection for enhancing safety and compliance while minimizing costly repairs
  • Rapid, accurate leak detection, boosting efficiency and client satisfaction in compressed air and gas system maintenance
  • Mechanical fault mode to detect faulty bearings to help plan repairs and avoid downtime
  • Power utilities
  • Manufacturing
  • Mining
  • Aerospace
  • Oil and gas
  • Facility maintenance
  • Research and development
  • Reliability consultants
  • Specialty service providers: Compressed air, refrigeration

How to Update Your Si2 Camera

The Si1 and Si2-series cameras can be updated using Over The Air (OTA) update, or through USB. To update your camera through USB, please follow the instructions below. Make sure that you read all the steps before attempting the update.

Requirements:

  • Ensure that the battery is fully charged. You will not receive any warning or message before starting the update
  • To ensure a successful update installation, we recommend utilizing an unrestricted computer or workstation. This will help prevent any loss of information during the download or transfer process
  • Use the USB flash drive supplied with the camera and make sure that the drive is empty.
  • Disable the Wi-Fi on the device. Settings -> Network Settings -> Disable Wi-Fi

Instructions:

  • 1. Insert the USB stick into the USB port and wait for a couple of seconds (an hourglass/waiting icon appears on the screen)

Please make sure that the internal Si2 memory does not contain any snapshot files, otherwise the USB update will not start.

*NOTE: DO NOT remove the USB stick until the camera instructs you to remove it, see image on step nr 4.

  • 2. Wait until the following prompt message is displayed: "Update file detected. Apply? Yes or No", tap on Yes.
  • 3. An status message is shown: "Please wait. copying update file...", the update is in process, please wait for 15 minutes.
  • 4. Once the installation is completed, a confirmation message will appear: "Update copied. Remove the USB stick and restart the device to apply the update.", please tap OK
  • 5. Now you can restart the camera. To restart the camera, first turn it off by long-pressing the power button until it turns red. Wait until it the Red LED light stops glowing, then turn it back on by short-pressing the button until it turns green.

Installation:

  • 1. When turning on the camera, the device screen displays that the update is being installed
  • 2. Wait until the installation is completed, this process takes around 10 minutes
  • 3. The camera will display the FLIR logo, and then switch to the main screen (live view). The update has been now been installed successfully

*Note: If the mode selection at start up is enabled, the camera will display the mode selection screen first. Select a mode and then accept to be directed to the live view

Verification:

  • 1. To confirm that your camera software is up-to-date, look at the text box at the bottom of the screen after pressing the settings menu. The device info displays the latest version of the software
  • 2. The camera is ready for normal operation

If your camera currently has 25H1, follow the instructions in FLIR Customer Help – Option 1: Automatic Update Notification

If your camera has an older release than 25H1, follow the instructions in FLIR Customer Help – Step 2: Camera Update OTA

FLIR Si2-LD No WiFi Specifications

Acoustic Measurement 124 low-noise MEMS microphones, real-time sound visualization
Detection Threshold 20 kHz: -15 dB SPL
35 kHz: 4 dB SPL
50 kHz: 10 dB SPL
80 kHz: 36 dB SPL
100 kHz: 51 dB SPL
Bandwidth 2 to 130 kHz
Directional Resolution From 1° up to 0.125°
Operating Distance From 1' (0.3 m) up to 656' (200 m)
Leak Localization and Detection Automatic leak recognition including estimated leak size and annual cost
Leak Rate Detection Threshold 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m
Gases detected Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas, and nitrogen
Other Acoustic Analysis Modes Mechanical fault detection
Digital Camera 12 MP color
Camera Field of View 75° diagonal
Video Frame Rate Camera: 60 fps
Acoustic image: 30 fps
Screen: 70 fps
Zoom 8x digital zoom
Video Image Resolution 1280 × 720
Display Size: 5" (127 mm), 1280 x 720
Resistive touch screen, TFT LCD, MIPI DSI
Integrated Flashlight LEDs, three modes off, normal and bright
Analysis and Reporting Online: FLIR Acoustic Camera Viewer (Cloud service)
Offline: FLIR Thermal Studio (desktop software)
Communication and Data Storage Data transfer: USB memory stick
Camera software update: USB connection
Still image format: .nlz and .jpg
Video recording and format: Up to 5 minutes (.nlz format)
Storage, internal: 128 GB (SD card)
Storage, external: USB 8 GB, Cloud storage capacity is unlimited
Image annotations: GPS, image tags and comments connection
Power Supply Camera power input:
Nominal input voltage: 12 V DC
Maximum input: 17 V DC, 3.3 A (limited)

Battery:
Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh
Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product)
Charge time: Approximately 2 hours
Maximum output: 16.8 V DC, 5 A

Battery charger:
Input: 19 to 26 V DC, 2.8 A
Maximum output: 17.4 V DC, 4.8 A
Environmental Data Operating temperature range: 14 to 122°F (-10 to 50°C)
Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery)
Relative humidity: 0 to 90% recommended
EMC: CFR47 FCC part 15 subpart B
Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893
Protection class: IP54
Safety: IEC 62368-1
Dimensions Camera: 7.2 x 10.8 x 6.5" (184 x 276 x 167 mm)
Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504
Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm)
Weight Camera: 2.64 lbs (1.2 kg)
Battery: 0.55 lbs (0.25 kg)
Camera + battery: 3.2 lbs (1.45 kg)
Packaging: 13 lbs (6 kg)
Click here for complete specifications on the FLIR Si2-LD No WiFi

What's included with the FLIR Si2-LD No WiFi

  • Industrial Acoustic Imaging Camera
  • Neck Strap
  • USB Memory Stick
  • Hard Carrying Case
  • 2 x Batteries
  • Battery Charger
  • 4 x Power Cables
  • License Card: FLIR Si-series Plugin for FLIR Thermal Studio, Perpetual License
  • Printed Documentation
  • Two to 10-Year Warranty

Click on a category to view a selection of compatible accessories with the FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720.

FLIR T912306 Battery RRC2054 for the Si1 and Si2 series T912306
Compatible with the Si1 and Si2 series acoustic imagers, this battery provides 2 hours of operation time.




Ask a question about FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720

Customer Reviews for the FLIR Si2-LD No WiFi

FLIR Si2-LD No WiFi Offers

Work with one-handed operations with this industrial acoustic imaging camera that features automatic tuning, 8x zoom, and a 12 MP digital camera. In addition, simplify finding critical mechanical issues, such as bearing faults with this camera's mechanical fault mode, automatic selection, and optimization of filters.

Features

  • Detects, locates, and measures compressed air and gas leaks; including bearing fault detection, from up to 656' (200 m) away
  • Built-in measurement and cost analysis for industrial gases including ammonia, hydrogen, CO2, methane, helium, and argon
  • One-handed operation with automatic tuning, 8x zoom, and a 12 MP digital camera
  • Mechanical fault mode, automatic selection, and optimization of filters simplifies finding critical mechanical issues, such as bearing faults
  • Fleet management functionality for efficient tool usage and maintenance across large-scale operations
  • Intuitive, light weight, one handed operation requiring minimal training
  • The highest performance acoustic imager available
  • Bearing assessment
  • Provides a greater return on investment for ultrasound inspection because the ease of use does not require experienced, trained technicians to get meaningful results
  • MECH mode camera operation allows quick detection and measurement of bearing and other mechanical issues that can lead to costly production disruption or safety hazards (three metrics provided for mechanical fault measurement)
  • Industrial gas quantification provides leak detection, leak rate and cost quantification for compressed air, methane, natural gas, ammonia, hydrogen, helium, and argon to find and prioritize repairs, and maximize return on investment
  • Lights can make a big difference: This camera features dual LED lamps to illuminate nearby dark areas

Applications

  • Detecting and quantifying leaks in manufacturing, production, and assembly applications; in all applications using compressed air
  • Early leak detection for enhancing safety and compliance while minimizing costly repairs
  • Rapid, accurate leak detection, boosting efficiency and client satisfaction in compressed air and gas system maintenance
  • Mechanical fault mode to detect faulty bearings to help plan repairs and avoid downtime
  • Power utilities
  • Manufacturing
  • Mining
  • Aerospace
  • Oil and gas
  • Facility maintenance
  • Research and development
  • Reliability consultants
  • Specialty service providers: Compressed air, refrigeration

How to Update Your Si2 Camera

The Si1 and Si2-series cameras can be updated using Over The Air (OTA) update, or through USB. To update your camera through USB, please follow the instructions below. Make sure that you read all the steps before attempting the update.

Requirements:

  • Ensure that the battery is fully charged. You will not receive any warning or message before starting the update
  • To ensure a successful update installation, we recommend utilizing an unrestricted computer or workstation. This will help prevent any loss of information during the download or transfer process
  • Use the USB flash drive supplied with the camera and make sure that the drive is empty.
  • Disable the Wi-Fi on the device. Settings -> Network Settings -> Disable Wi-Fi

Instructions:

  • 1. Insert the USB stick into the USB port and wait for a couple of seconds (an hourglass/waiting icon appears on the screen)

Please make sure that the internal Si2 memory does not contain any snapshot files, otherwise the USB update will not start.

*NOTE: DO NOT remove the USB stick until the camera instructs you to remove it, see image on step nr 4.

  • 2. Wait until the following prompt message is displayed: "Update file detected. Apply? Yes or No", tap on Yes.
  • 3. An status message is shown: "Please wait. copying update file...", the update is in process, please wait for 15 minutes.
  • 4. Once the installation is completed, a confirmation message will appear: "Update copied. Remove the USB stick and restart the device to apply the update.", please tap OK
  • 5. Now you can restart the camera. To restart the camera, first turn it off by long-pressing the power button until it turns red. Wait until it the Red LED light stops glowing, then turn it back on by short-pressing the button until it turns green.

Installation:

  • 1. When turning on the camera, the device screen displays that the update is being installed
  • 2. Wait until the installation is completed, this process takes around 10 minutes
  • 3. The camera will display the FLIR logo, and then switch to the main screen (live view). The update has been now been installed successfully

*Note: If the mode selection at start up is enabled, the camera will display the mode selection screen first. Select a mode and then accept to be directed to the live view

Verification:

  • 1. To confirm that your camera software is up-to-date, look at the text box at the bottom of the screen after pressing the settings menu. The device info displays the latest version of the software
  • 2. The camera is ready for normal operation

If your camera currently has 25H1, follow the instructions in FLIR Customer Help – Option 1: Automatic Update Notification

If your camera has an older release than 25H1, follow the instructions in FLIR Customer Help – Step 2: Camera Update OTA

FLIR Si2-LD No WiFi Specifications

Acoustic Measurement 124 low-noise MEMS microphones, real-time sound visualization
Detection Threshold 20 kHz: -15 dB SPL
35 kHz: 4 dB SPL
50 kHz: 10 dB SPL
80 kHz: 36 dB SPL
100 kHz: 51 dB SPL
Bandwidth 2 to 130 kHz
Directional Resolution From 1° up to 0.125°
Operating Distance From 1' (0.3 m) up to 656' (200 m)
Leak Localization and Detection Automatic leak recognition including estimated leak size and annual cost
Leak Rate Detection Threshold 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m
Gases detected Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas, and nitrogen
Other Acoustic Analysis Modes Mechanical fault detection
Digital Camera 12 MP color
Camera Field of View 75° diagonal
Video Frame Rate Camera: 60 fps
Acoustic image: 30 fps
Screen: 70 fps
Zoom 8x digital zoom
Video Image Resolution 1280 × 720
Display Size: 5" (127 mm), 1280 x 720
Resistive touch screen, TFT LCD, MIPI DSI
Integrated Flashlight LEDs, three modes off, normal and bright
Analysis and Reporting Online: FLIR Acoustic Camera Viewer (Cloud service)
Offline: FLIR Thermal Studio (desktop software)
Communication and Data Storage Data transfer: USB memory stick
Camera software update: USB connection
Still image format: .nlz and .jpg
Video recording and format: Up to 5 minutes (.nlz format)
Storage, internal: 128 GB (SD card)
Storage, external: USB 8 GB, Cloud storage capacity is unlimited
Image annotations: GPS, image tags and comments connection
Power Supply Camera power input:
Nominal input voltage: 12 V DC
Maximum input: 17 V DC, 3.3 A (limited)

Battery:
Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh
Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product)
Charge time: Approximately 2 hours
Maximum output: 16.8 V DC, 5 A

Battery charger:
Input: 19 to 26 V DC, 2.8 A
Maximum output: 17.4 V DC, 4.8 A
Environmental Data Operating temperature range: 14 to 122°F (-10 to 50°C)
Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery)
Relative humidity: 0 to 90% recommended
EMC: CFR47 FCC part 15 subpart B
Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893
Protection class: IP54
Safety: IEC 62368-1
Dimensions Camera: 7.2 x 10.8 x 6.5" (184 x 276 x 167 mm)
Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504
Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm)
Weight Camera: 2.64 lbs (1.2 kg)
Battery: 0.55 lbs (0.25 kg)
Camera + battery: 3.2 lbs (1.45 kg)
Packaging: 13 lbs (6 kg)
Click here for complete specifications on the FLIR Si2-LD No WiFi

What's included with the FLIR Si2-LD No WiFi

  • Industrial Acoustic Imaging Camera
  • Neck Strap
  • USB Memory Stick
  • Hard Carrying Case
  • 2 x Batteries
  • Battery Charger
  • 4 x Power Cables
  • License Card: FLIR Si-series Plugin for FLIR Thermal Studio, Perpetual License
  • Printed Documentation
  • Two to 10-Year Warranty

Click on a category to view a selection of compatible accessories with the FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720.

FLIR T912306 Battery RRC2054 for the Si1 and Si2 series T912306
Compatible with the Si1 and Si2 series acoustic imagers, this battery provides 2 hours of operation time.




Ask a question about FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720

Customer Reviews for the FLIR Si2-LD No WiFi

More FLIR Products