Designed for pressurized leak detection and mechanical fault detection, this industrial acoustic imaging camera (Non-Wi-Fi model) detects, locates, and measures compressed air and gas leaks. In addition, this camera features built-in measurement and cost analysis for industrial gases such as ammonia, hydrogen, CO2, methane, helium, and argon.
Designed for pressurized leak detection and mechanical fault detection, this industrial acoustic imaging camera (Non-Wi-Fi model) detects, locates, and measures compressed air and gas leaks. In addition, this camera features built-in measurement and cost analysis for industrial gases such as ammonia, hydrogen, CO2, methane, helium, and argon.
Work with one-handed operations with this industrial acoustic imaging camera that features automatic tuning, 8x zoom, and a 12 MP digital camera. In addition, simplify finding critical mechanical issues, such as bearing faults with this camera's mechanical fault mode, automatic selection, and optimization of filters.
Features
Applications
How to Update Your Si2 Camera
The Si1 and Si2-series cameras can be updated using Over The Air (OTA) update, or through USB. To update your camera through USB, please follow the instructions below. Make sure that you read all the steps before attempting the update.
Requirements:
Instructions:
Please make sure that the internal Si2 memory does not contain any snapshot files, otherwise the USB update will not start.
*NOTE: DO NOT remove the USB stick until the camera instructs you to remove it, see image on step nr 4.
Installation:
*Note: If the mode selection at start up is enabled, the camera will display the mode selection screen first. Select a mode and then accept to be directed to the live view
Verification:
If your camera currently has 25H1, follow the instructions in FLIR Customer Help – Option 1: Automatic Update Notification
If your camera has an older release than 25H1, follow the instructions in FLIR Customer Help – Step 2: Camera Update OTA
| Acoustic Measurement | 124 low-noise MEMS microphones, real-time sound visualization |
| Detection Threshold | 20 kHz: -15 dB SPL 35 kHz: 4 dB SPL 50 kHz: 10 dB SPL 80 kHz: 36 dB SPL 100 kHz: 51 dB SPL |
| Bandwidth | 2 to 130 kHz |
| Directional Resolution | From 1° up to 0.125° |
| Operating Distance | From 1' (0.3 m) up to 656' (200 m) |
| Leak Localization and Detection | Automatic leak recognition including estimated leak size and annual cost |
| Leak Rate Detection Threshold | 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m |
| Gases detected | Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas, and nitrogen |
| Other Acoustic Analysis Modes | Mechanical fault detection |
| Digital Camera | 12 MP color |
| Camera Field of View | 75° diagonal |
| Video Frame Rate | Camera: 60 fps Acoustic image: 30 fps Screen: 70 fps |
| Zoom | 8x digital zoom |
| Video Image Resolution | 1280 × 720 |
| Display | Size: 5" (127 mm), 1280 x 720 Resistive touch screen, TFT LCD, MIPI DSI |
| Integrated Flashlight | LEDs, three modes off, normal and bright |
| Analysis and Reporting | Online: FLIR Acoustic Camera Viewer (Cloud service) Offline: FLIR Thermal Studio (desktop software) |
| Communication and Data Storage | Data transfer: USB memory stick Camera software update: USB connection Still image format: .nlz and .jpg Video recording and format: Up to 5 minutes (.nlz format) Storage, internal: 128 GB (SD card) Storage, external: USB 8 GB, Cloud storage capacity is unlimited Image annotations: GPS, image tags and comments connection |
| Power Supply | Camera power input: Nominal input voltage: 12 V DC Maximum input: 17 V DC, 3.3 A (limited) Battery: Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product) Charge time: Approximately 2 hours Maximum output: 16.8 V DC, 5 A Battery charger: Input: 19 to 26 V DC, 2.8 A Maximum output: 17.4 V DC, 4.8 A |
| Environmental Data | Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery) Relative humidity: 0 to 90% recommended EMC: CFR47 FCC part 15 subpart B Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893 Protection class: IP54 Safety: IEC 62368-1 |
| Dimensions | Camera: 7.2 x 10.8 x 6.5" (184 x 276 x 167 mm) Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504 Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm) |
| Weight | Camera: 2.64 lbs (1.2 kg) Battery: 0.55 lbs (0.25 kg) Camera + battery: 3.2 lbs (1.45 kg) Packaging: 13 lbs (6 kg) |
Click on a category to view a selection of compatible accessories with the FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720.
| Acoustic Measurement | 124 low-noise MEMS microphones, real-time sound visualization |
| Detection Threshold | 20 kHz: -15 dB SPL 35 kHz: 4 dB SPL 50 kHz: 10 dB SPL 80 kHz: 36 dB SPL 100 kHz: 51 dB SPL |
| Bandwidth | 2 to 130 kHz |
| Directional Resolution | From 1° up to 0.125° |
| Operating Distance | From 1' (0.3 m) up to 656' (200 m) |
| Leak Localization and Detection | Automatic leak recognition including estimated leak size and annual cost |
| Leak Rate Detection Threshold | 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m |
| Gases detected | Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas, and nitrogen |
| Other Acoustic Analysis Modes | Mechanical fault detection |
| Digital Camera | 12 MP color |
| Camera Field of View | 75° diagonal |
| Video Frame Rate | Camera: 60 fps Acoustic image: 30 fps Screen: 70 fps |
| Zoom | 8x digital zoom |
| Video Image Resolution | 1280 × 720 |
| Display | Size: 5" (127 mm), 1280 x 720 Resistive touch screen, TFT LCD, MIPI DSI |
| Integrated Flashlight | LEDs, three modes off, normal and bright |
| Analysis and Reporting | Online: FLIR Acoustic Camera Viewer (Cloud service) Offline: FLIR Thermal Studio (desktop software) |
| Communication and Data Storage | Data transfer: USB memory stick Camera software update: USB connection Still image format: .nlz and .jpg Video recording and format: Up to 5 minutes (.nlz format) Storage, internal: 128 GB (SD card) Storage, external: USB 8 GB, Cloud storage capacity is unlimited Image annotations: GPS, image tags and comments connection |
| Power Supply | Camera power input: Nominal input voltage: 12 V DC Maximum input: 17 V DC, 3.3 A (limited) Battery: Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product) Charge time: Approximately 2 hours Maximum output: 16.8 V DC, 5 A Battery charger: Input: 19 to 26 V DC, 2.8 A Maximum output: 17.4 V DC, 4.8 A |
| Environmental Data | Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery) Relative humidity: 0 to 90% recommended EMC: CFR47 FCC part 15 subpart B Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893 Protection class: IP54 Safety: IEC 62368-1 |
| Dimensions | Camera: 7.2 x 10.8 x 6.5" (184 x 276 x 167 mm) Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504 Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm) |
| Weight | Camera: 2.64 lbs (1.2 kg) Battery: 0.55 lbs (0.25 kg) Camera + battery: 3.2 lbs (1.45 kg) Packaging: 13 lbs (6 kg) |
Click on a category to view a selection of compatible accessories with the FLIR Si2-LD Industrial Acoustic Imaging Camera, No Wi-Fi, 2 to 130 kHz, 1280 x 720.