Features
Applications
Electrical Measurement | |
Maximum Power Value (Pmax) | Range: 0 W to 800 W Accuracy: ±5% |
Voltage at MMPT point (Vmax) | Range: 0 V to 60 V Accuracy: ±5% |
Current at MMPT point (Imax) | Range: 0 A to 30 A Accuracy: ±5% |
Open Circuit Voltage (VOC) | Range: 0 V to 60 V Accuracy: ±1% |
Short Circuit Current (ISC) | Range: 0 A to 30 A Accuracy: ±1% |
Device Temperature Protection | Range: 0°C to 60°C Accuracy: ±3% |
Measuring rate | 3 samples per second |
Power System | |
Display | TFT Display |
Backlight | White LED array |
Warranty | Limited 3-Year Warranty |
Calibration cycle | Once per year, recommended |
Certifications | |
Certifications | CE, RCM, FCC |
Safety standards | IEC 61010-1 |
EMC standards | EN61326-1 |
Environmental Data | |
Operating ambient temp & RH | −10°C to 50°C (14°F to 122°F), <80% RH |
Storage temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH |
Operating altitude | 2000 m (6560 ft) |
Pollution degree | 2 |
Meter Physical Data | |
Dimensions | 151.6 mm × 72.5 mm × 38 mm (5.97 in × 2.85 in × 1.50 in) |
Weight | 206 g (0.45 lbs) |
Click on a category to view a selection of compatible accessories with the FLIR PV48 Solar Panel I-V Curve Tracer.
Electrical Measurement | |
Maximum Power Value (Pmax) | Range: 0 W to 800 W Accuracy: ±5% |
Voltage at MMPT point (Vmax) | Range: 0 V to 60 V Accuracy: ±5% |
Current at MMPT point (Imax) | Range: 0 A to 30 A Accuracy: ±5% |
Open Circuit Voltage (VOC) | Range: 0 V to 60 V Accuracy: ±1% |
Short Circuit Current (ISC) | Range: 0 A to 30 A Accuracy: ±1% |
Device Temperature Protection | Range: 0°C to 60°C Accuracy: ±3% |
Measuring rate | 3 samples per second |
Power System | |
Display | TFT Display |
Backlight | White LED array |
Warranty | Limited 3-Year Warranty |
Calibration cycle | Once per year, recommended |
Certifications | |
Certifications | CE, RCM, FCC |
Safety standards | IEC 61010-1 |
EMC standards | EN61326-1 |
Environmental Data | |
Operating ambient temp & RH | −10°C to 50°C (14°F to 122°F), <80% RH |
Storage temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH |
Operating altitude | 2000 m (6560 ft) |
Pollution degree | 2 |
Meter Physical Data | |
Dimensions | 151.6 mm × 72.5 mm × 38 mm (5.97 in × 2.85 in × 1.50 in) |
Weight | 206 g (0.45 lbs) |
Click on a category to view a selection of compatible accessories with the FLIR PV48 Solar Panel I-V Curve Tracer.