FLIR EV86-T2 EV Charger Analyzer, 440 V, RCD trip test

Model: EV86-T2 | UPC: 793950603000

FLIR EV86-T2 EV Charger Analyzer, 440 V, RCD trip test

Model: EV86-T2 | UPC: 793950603000

Designed for EV charging commissioning, this EV charger analyzer verifies RCD trip current, protective earth (PE) safety, and simulates Control Pilot states while measuring CP waveforms to diagnose EVSE faults. In addition, it connects seamlessly with the Meterlink® App, allowing data transfer and convenient reporting. It is suited for installation, service, and validation of system performance.

Designed for EV charging commissioning, this EV charger analyzer verifies RCD trip current, protective earth (PE) safety, and simulates Control Pilot states while measuring CP waveforms to diagnose EVSE faults. In addition, it connects seamlessly with the Meterlink® App, allowing data transfer and convenient reporting. It is suited for installation, service, and validation of system performance.

Your Price $2399.99 USD
Availability 2 to 3 Weeks
Quantity

FLIR EV86-T2 Offers

Features

  • Perform a Protective Earth (PE) pre-test to verify no dangerous voltage is present before testing begins
  • Simulate Control Pilot (CP) states, analyze CP waveforms, and perform error simulations to evaluate EVSE operation and diagnose faults
  • Verify RCD trip current and trip time, measure loop impedance, and display key electrical parameters including voltage, frequency, phase, peak voltage, and duty cycle
  • Streamline workflows with automated test sequences and Bluetooth Meterlink connectivity for wireless data transfer and mobile app reporting

Applications

  • Safety, functionality, and performance verification of newly installed public and private AC EV charging stations
  • EVSE fault diagnosis, repair validation, and routine testing to keep charging infrastructure operating safely and reliably
  • EV charging system validation for EV charger manufacturers to help ensure systems meet safety and reliability requirements

FLIR EV86-T2 Specifications

PE Contact/Pre-Test Range: 50 V AC/DC
Accuracy: ±2.0%, pass/fault at greater than 50 V AC/DC between PE conductor and touch sensor
Input Electrical Ratings 1 Φ: 250 V maximum, 3 Φ: 230/440 V maximum, 50/60 Hz, maximum 10 A
Main Voltage Range: 440 V
Accuracy: ±2.0%
Frequency Range: 2 kHz
Accuracy: ±1 Hz
Duty Cycle Range: 100%
Accuracy: ±5 digits
PP State Indication Not connected, connected, connected + latch
Maximum Charging Current Indication 13 A, 20 A, 32 A, 63 A
CP State Simulation and Waveform A (disconnected), B (connected), C (charging), D (charging w/ ventilation), E (error occurred), F (error occurred)
Voltage Phase Indication L1, L2, L3, PE, N
RCD Trip current and time:
Range: 31.5 mA AC, 300 ms
Accuracy: ±2.0%

Range: 6 mA DC, 12.5 s for less than 2.5 s
Accuracy: ±1.0%


Ramping current (0°, 180°):
Range: 6 mA DC in 2.5 s smooth ramp every 2 mA DC; 30 mA AC in 2 mA steps every 300 ms in 0.5 s
Accuracy: ±2.0%
Loop Impedance Range: 2.000 kΩ
Accuracy: ±1.0%
Auto Testing Items PE contact test, EVSE interface, RCD test, and loop impedance test in settings menu
System Power Battery: rechargeable Li-battery
Battery life: 12 hours continuously
Auto power off: after approximately 15 minutes of inactivity
Display 3.5" (8.89 cm) TFT-LCD
Connector (Built-In) IEC 62196-2 Type 2 socket
Accessory Converter IEC 62196-2 Type 2 to SAE J1772 Type 1
Category Rating CAT II-300 V
Certifications Certifications: ETL, CE, FCC
Safety standards: IEC 61010-1, CAT II-300 V
EMC standards: EN61326-1
Connectivity Wireless technology: Bluetooth BLE
Communications protocol: Meterlink
Bluetooth range: 32' (10 m)
Environmental Conditions Operating ambient temperature and RH:
14 to 86°F (-10 to 30°C), <85% RH
86 to 104°F (30 to 40°C), <75% RH
104 to 122°F (40 to 50°C), <45% RH

Storage temperature and RH: -4 to 140°F (-20 to 60°C), 0 to 80% RH

Operating altitude: 6560' (2000 m)

Pollution degree: 2
Dimensions 11.6 x 3.68 x 2" (29.6 x 9.35 x 5 cm)
Weight 1.7 lbs (760 g)
Click here for complete specifications on the FLIR EV86-T2

What's included with the FLIR EV86-T2

  • EV Charger Analyzer
  • Type 2 to Type 1 Converter
  • Type-A to C USB Cable
  • Neck Strap
  • Carrying Case
  • Quick Start Guide
  • Limited Three-Year Warranty

Ask a question about FLIR EV86-T2 EV Charger Analyzer, 440 V, RCD trip test

Customer Reviews for the FLIR EV86-T2

FLIR EV86-T2 Offers

Features

  • Perform a Protective Earth (PE) pre-test to verify no dangerous voltage is present before testing begins
  • Simulate Control Pilot (CP) states, analyze CP waveforms, and perform error simulations to evaluate EVSE operation and diagnose faults
  • Verify RCD trip current and trip time, measure loop impedance, and display key electrical parameters including voltage, frequency, phase, peak voltage, and duty cycle
  • Streamline workflows with automated test sequences and Bluetooth Meterlink connectivity for wireless data transfer and mobile app reporting

Applications

  • Safety, functionality, and performance verification of newly installed public and private AC EV charging stations
  • EVSE fault diagnosis, repair validation, and routine testing to keep charging infrastructure operating safely and reliably
  • EV charging system validation for EV charger manufacturers to help ensure systems meet safety and reliability requirements

FLIR EV86-T2 Specifications

PE Contact/Pre-Test Range: 50 V AC/DC
Accuracy: ±2.0%, pass/fault at greater than 50 V AC/DC between PE conductor and touch sensor
Input Electrical Ratings 1 Φ: 250 V maximum, 3 Φ: 230/440 V maximum, 50/60 Hz, maximum 10 A
Main Voltage Range: 440 V
Accuracy: ±2.0%
Frequency Range: 2 kHz
Accuracy: ±1 Hz
Duty Cycle Range: 100%
Accuracy: ±5 digits
PP State Indication Not connected, connected, connected + latch
Maximum Charging Current Indication 13 A, 20 A, 32 A, 63 A
CP State Simulation and Waveform A (disconnected), B (connected), C (charging), D (charging w/ ventilation), E (error occurred), F (error occurred)
Voltage Phase Indication L1, L2, L3, PE, N
RCD Trip current and time:
Range: 31.5 mA AC, 300 ms
Accuracy: ±2.0%

Range: 6 mA DC, 12.5 s for less than 2.5 s
Accuracy: ±1.0%


Ramping current (0°, 180°):
Range: 6 mA DC in 2.5 s smooth ramp every 2 mA DC; 30 mA AC in 2 mA steps every 300 ms in 0.5 s
Accuracy: ±2.0%
Loop Impedance Range: 2.000 kΩ
Accuracy: ±1.0%
Auto Testing Items PE contact test, EVSE interface, RCD test, and loop impedance test in settings menu
System Power Battery: rechargeable Li-battery
Battery life: 12 hours continuously
Auto power off: after approximately 15 minutes of inactivity
Display 3.5" (8.89 cm) TFT-LCD
Connector (Built-In) IEC 62196-2 Type 2 socket
Accessory Converter IEC 62196-2 Type 2 to SAE J1772 Type 1
Category Rating CAT II-300 V
Certifications Certifications: ETL, CE, FCC
Safety standards: IEC 61010-1, CAT II-300 V
EMC standards: EN61326-1
Connectivity Wireless technology: Bluetooth BLE
Communications protocol: Meterlink
Bluetooth range: 32' (10 m)
Environmental Conditions Operating ambient temperature and RH:
14 to 86°F (-10 to 30°C), <85% RH
86 to 104°F (30 to 40°C), <75% RH
104 to 122°F (40 to 50°C), <45% RH

Storage temperature and RH: -4 to 140°F (-20 to 60°C), 0 to 80% RH

Operating altitude: 6560' (2000 m)

Pollution degree: 2
Dimensions 11.6 x 3.68 x 2" (29.6 x 9.35 x 5 cm)
Weight 1.7 lbs (760 g)
Click here for complete specifications on the FLIR EV86-T2

What's included with the FLIR EV86-T2

  • EV Charger Analyzer
  • Type 2 to Type 1 Converter
  • Type-A to C USB Cable
  • Neck Strap
  • Carrying Case
  • Quick Start Guide
  • Limited Three-Year Warranty