For waste plants and substations where spontaneous fires are a risk, this IP67 640 x 480 Thermal Imager measures -4 to 3632°F (-20 to 2000°C) with ±2°C accuracy through a motorized 80° lens.
For waste plants and substations where spontaneous fires are a risk, this IP67 640 x 480 Thermal Imager measures -4 to 3632°F (-20 to 2000°C) with ±2°C accuracy through a motorized 80° lens.
FLIR A500f/A700f cameras offer high-resolution thermal imaging paired with edge computing and industrial internet of things (IIoT) for simplified inclusion in new or existing networks. For VMS integrations, thermal and visible streams can be viewed independently or simultaneously. The cameras are easy to add, set up, and operate in HMI/SCADA systems, offering automation system solution providers a running start. FLIR A500f/A700f cameras can help companies protect assets, improve safety, maximize uptime, and minimize maintenance costs.
Features
Applications
| System Overview | |
| IR Resolution | 640 x 480 (307,200 pixels) |
| Visual Resolution | 1280 x 960 (not applicable for 80° version) |
| Detector Pitch | 0.00047" (12 μm) |
| MSX® & FSX® | Yes (MSX is not available for 80° version) |
| Field of Views | 80° |
| Focal Plane Array (FPA) | Uncooled microbolometer |
| Focus | Motorized focus, manual and on-command automatic (scene contrast method) |
| Image Frequency | 30 Hz |
| Image Storage | Records up to 100 FLIR radiometric JPEG; storage as function of alarm, scheduling, or user interaction (camera web) |
| Measurement | |
| Object Temperature Range | -4°F to 248°F (-20°C to 120°C) 32°F to 1202°F (0°C to 650°C) 572°F to 3632°F (300°C to 2000°C) |
| Accuracy | ±3.6°F (±2°C) or ±2% of reading, for ambient temperature 59 to 95°F (15 to 35°C) and object temperature above 32°F (0°C) |
| Readout | Measurement results: Ethernet/IP, Modbus TCP server (pull), Modbus TCP client (push), MQTT (push), REST API (GET/POST), measurements and still image (radiometric JPEG, visual 640 x 480, visual 1280 x 960), web interface |
| Automatic Hot and Cold Detection | Max/min temperature value and position shown within box, polygon, line or polyline |
| Measurement Presets | Yes |
| Measurement Tools | 10 spotmeters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline, maximum 12 measurement functions at the same time |
| Web Interface | Yes |
| Multi Streaming | Yes |
| Alarm | |
| Alarm Functions | On any selected measurement function, digital in, and internal camera temperature |
| Alarm Output | Digital out, e-mail (SMTP) (push), Ethernet/IP, file transfer (FTP) (push), Modbus TCP server (pull), MQTT (push), query over RESTful API (pull), store image or video |
| Encoding | Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS over RTSP |
| Digital Input/Output | |
| Digital I/O Connector Type | Terminal block inside housing |
| Digital I/O Isolation Voltage | 500 VRMS |
| Digital Input Purpose | NUC, NUC disable, alarm |
| Digital Inputs | 2x opto-isolated, Vin(low)=0–1.5 V, Vin(high)=3–25 V |
| Digital Output Purpose | As a function of alarm, output to external device, Fault (NC) |
| Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
| Cable Glands | 1x M12 (0.47" / 12 mm), 1x M16 (0.63" / 16 mm), 1x M20 (0.79" / 20 mm) |
| Ethernet | |
| Ethernet | For control, result, image, and power |
| Ethernet Communication | TCP/IP socket-based FLIR proprietary |
| Ethernet Connector Type | IP67 rated RJ45 port |
| Ethernet Interface | Wired |
| Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 EtherNet/IP, IEEE 1588, Modbus TCP, MQTT, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, PoE injector sold separately |
| Environmental Data | |
| Operating Temperature Range | -22 to 122°F (-30 to 50°C) |
| EMC | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B |
| Encapsulation | IP67 |
| System Features | |
| Heater | 8 W, electronically controlled, T_ON 68°F ±4°F (20°C ±2°C), T_OFF 73.4°F ±4°F (23°C ±2°C) |
| ONVIF Conformance | Yes. ONVIF Profile S |
| Window Transmission | Automatic, based on window temperature |
| Power Consumption | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus |
| Physical Data | |
| Mounting | Sold separately, pole and wall adapters available |
| Housing Material | Aluminum housing, sunshield in ABS |
| Packaging Size (L x W x H) | 24.41 x 7.92 x 8.66" (62 x 20.2 x 22 cm) |
| Size (L x W x H) | 20.28 x 6.97 x 9.02" (51.5 x 17.7 x 22.9 cm) |
Click on a category to view a selection of compatible accessories with the FLIR A700f Series Thermal Imager, 640 x 480, 80° FOV, -4 to 3632°F, environmental housing, fixed-mount.
| System Overview | |
| IR Resolution | 640 x 480 (307,200 pixels) |
| Visual Resolution | 1280 x 960 (not applicable for 80° version) |
| Detector Pitch | 0.00047" (12 μm) |
| MSX® & FSX® | Yes (MSX is not available for 80° version) |
| Field of Views | 80° |
| Focal Plane Array (FPA) | Uncooled microbolometer |
| Focus | Motorized focus, manual and on-command automatic (scene contrast method) |
| Image Frequency | 30 Hz |
| Image Storage | Records up to 100 FLIR radiometric JPEG; storage as function of alarm, scheduling, or user interaction (camera web) |
| Measurement | |
| Object Temperature Range | -4°F to 248°F (-20°C to 120°C) 32°F to 1202°F (0°C to 650°C) 572°F to 3632°F (300°C to 2000°C) |
| Accuracy | ±3.6°F (±2°C) or ±2% of reading, for ambient temperature 59 to 95°F (15 to 35°C) and object temperature above 32°F (0°C) |
| Readout | Measurement results: Ethernet/IP, Modbus TCP server (pull), Modbus TCP client (push), MQTT (push), REST API (GET/POST), measurements and still image (radiometric JPEG, visual 640 x 480, visual 1280 x 960), web interface |
| Automatic Hot and Cold Detection | Max/min temperature value and position shown within box, polygon, line or polyline |
| Measurement Presets | Yes |
| Measurement Tools | 10 spotmeters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline, maximum 12 measurement functions at the same time |
| Web Interface | Yes |
| Multi Streaming | Yes |
| Alarm | |
| Alarm Functions | On any selected measurement function, digital in, and internal camera temperature |
| Alarm Output | Digital out, e-mail (SMTP) (push), Ethernet/IP, file transfer (FTP) (push), Modbus TCP server (pull), MQTT (push), query over RESTful API (pull), store image or video |
| Encoding | Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS over RTSP |
| Digital Input/Output | |
| Digital I/O Connector Type | Terminal block inside housing |
| Digital I/O Isolation Voltage | 500 VRMS |
| Digital Input Purpose | NUC, NUC disable, alarm |
| Digital Inputs | 2x opto-isolated, Vin(low)=0–1.5 V, Vin(high)=3–25 V |
| Digital Output Purpose | As a function of alarm, output to external device, Fault (NC) |
| Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
| Cable Glands | 1x M12 (0.47" / 12 mm), 1x M16 (0.63" / 16 mm), 1x M20 (0.79" / 20 mm) |
| Ethernet | |
| Ethernet | For control, result, image, and power |
| Ethernet Communication | TCP/IP socket-based FLIR proprietary |
| Ethernet Connector Type | IP67 rated RJ45 port |
| Ethernet Interface | Wired |
| Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 EtherNet/IP, IEEE 1588, Modbus TCP, MQTT, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, PoE injector sold separately |
| Environmental Data | |
| Operating Temperature Range | -22 to 122°F (-30 to 50°C) |
| EMC | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B |
| Encapsulation | IP67 |
| System Features | |
| Heater | 8 W, electronically controlled, T_ON 68°F ±4°F (20°C ±2°C), T_OFF 73.4°F ±4°F (23°C ±2°C) |
| ONVIF Conformance | Yes. ONVIF Profile S |
| Window Transmission | Automatic, based on window temperature |
| Power Consumption | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus |
| Physical Data | |
| Mounting | Sold separately, pole and wall adapters available |
| Housing Material | Aluminum housing, sunshield in ABS |
| Packaging Size (L x W x H) | 24.41 x 7.92 x 8.66" (62 x 20.2 x 22 cm) |
| Size (L x W x H) | 20.28 x 6.97 x 9.02" (51.5 x 17.7 x 22.9 cm) |
Click on a category to view a selection of compatible accessories with the FLIR A700f Series Thermal Imager, 640 x 480, 80° FOV, -4 to 3632°F, environmental housing, fixed-mount.