SPK3 IR Laser and Probe Thermometer features a built-in rod thermometer for close-up duct temperatures and an IR thermometer for longer-range temperatures. Easily hangs on almost any vent register for hands-free measuring.
SPK3 IR Laser and Probe Thermometer features a built-in rod thermometer for close-up duct temperatures and an IR thermometer for longer-range temperatures. Easily hangs on almost any vent register for hands-free measuring.
Fieldpiece SPK3 IR ThermometerFolding Rod Thermometer with 8:1 IRThe Fieldpiece SPK3 IR Laser and Probe Thermometer features a built-in rod thermometer for close-up duct temperatures and an IR thermometer for longer range temperatures. Easily hangs on almost any vent registers for hands-free measuring.
Features
Applications
Probe length | 94 mm (~3.75") long |
Operating environment | 32 to 104°F (<90% RH) |
Storage environment | 14 to 140°F (<70% RH) |
Battery | 2 x AAA (installed) |
Battery life (alkaline) | 40 hrs (IR), 750 hrs (ROD) |
Auto-off | 3 min, 15 min (T1-T2 mode) |
Range | -20 to 932°F (-30 to 500°C) |
Best resolution | 0.5°F/0.2°C |
Accuracy (at 73°F, <80%RH, calibrated at 30cm) | ±4°F (±2°C), (-20 to 32°F) ±3°F (±1.5°C), (32 to 50°F) ±2°F (±1°C), (50 to 104°F) ±3°F (±1.5°C) or 1.5% of rdg |
Field of view (DS) | 0.334027777777778 |
Response time | 0.5 seconds |
Wavelength | 8 to 14μm |
Emissivity | E=0.95 |
Rod Range | -40 to 257°F (-40 to 125°C) |
Best resolution | 0.1°F/0.1°C |
Accuracy (at 73°F, <80%RH) | ±1°F (±0.5°C), (32 to 122°F) ±2°F (±1.0°C), (<32°F, >122°F) |
Response time | 20 seconds |
Click on a category to view a selection of compatible accessories with the Fieldpiece SPK3 IR Laser and Probe Thermometer.
Probe length | 94 mm (~3.75") long |
Operating environment | 32 to 104°F (<90% RH) |
Storage environment | 14 to 140°F (<70% RH) |
Battery | 2 x AAA (installed) |
Battery life (alkaline) | 40 hrs (IR), 750 hrs (ROD) |
Auto-off | 3 min, 15 min (T1-T2 mode) |
Range | -20 to 932°F (-30 to 500°C) |
Best resolution | 0.5°F/0.2°C |
Accuracy (at 73°F, <80%RH, calibrated at 30cm) | ±4°F (±2°C), (-20 to 32°F) ±3°F (±1.5°C), (32 to 50°F) ±2°F (±1°C), (50 to 104°F) ±3°F (±1.5°C) or 1.5% of rdg |
Field of view (DS) | 0.334027777777778 |
Response time | 0.5 seconds |
Wavelength | 8 to 14μm |
Emissivity | E=0.95 |
Rod Range | -40 to 257°F (-40 to 125°C) |
Best resolution | 0.1°F/0.1°C |
Accuracy (at 73°F, <80%RH) | ±1°F (±0.5°C), (32 to 122°F) ±2°F (±1.0°C), (<32°F, >122°F) |
Response time | 20 seconds |
Click on a category to view a selection of compatible accessories with the Fieldpiece SPK3 IR Laser and Probe Thermometer.