SM380V SMAN is the newly designed wireless, three-port, manifold with a built-in micron gauge designed to check, evaluate, and charge A/C systems. This digital manifold has been upgraded for ultimate field protection and long-range wireless communication. This manifold includes a fully rubberized case that seals and protects it from dust, bumps, and light rain, and the heavy-duty hook allows you to hang it in your work vehicle or job site.
SM380V SMAN is the newly designed wireless, three-port, manifold with a built-in micron gauge designed to check, evaluate, and charge A/C systems. This digital manifold has been upgraded for ultimate field protection and long-range wireless communication. This manifold includes a fully rubberized case that seals and protects it from dust, bumps, and light rain, and the heavy-duty hook allows you to hang it in your work vehicle or job site.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The A/C specialist can view the calculated target superheat while monitoring, in real-time, how their change is affecting actual superheat and subcooling. All measurements and live calculations such as pipe temperatures, refrigerant usage and indoor air temperatures can be viewed on the extra-large LCD screen or on a mobile device up to 1000 feet (305 meters) when connected to the Job Link System App. In addition, when using the Job Link App, work can be documented and reports generated all from the smartphone or tablet.
The SMAN 380V includes over 70 refrigerants pre-programmed and a rolling list of ten most recently used refrigerants stored at the top of the main refrigerant list for quick selection. The current refrigerant is automatically added to this list of ten refrigerants when the manifold powers off.
The Fieldpiece SM380V digital manifold with micron gauge includes some customizable features, such as adjustable auto power off duration, ability to adjust the backlight duration, set high and low vacuum alarms, and select each unit of measurement individually.
A Tightness Test function is available to check for leaks after repairs or installations as well as the ability to view pressure differential over time. The timer tracks the duration of the test and temperature is compensated with SL temp to avoid false positives.
You can connect wirelessly to psychrometers, pipe clamps, and even a refrigeration scale in addition to using the thermocouples. Up to nine jobs can be saved to the internal flash drive.
The Fieldpiece SMAN 380 has an extremely durable impact resistant case, reinforced hook, hermetically sealed sight glass, and is water resistant with an IP54 rating. In addition, the three protected thermocouple jacks have been moved to the back for additional protection. Note: Fieldpiece SM380V is a direct replacement of popular Fieldpiece sman360.
Features
Features
Rugged Construction:
Applications
| Pressure | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | 580 Psig (English) 40.00 Bar (Metric) 4.000 MPa (Metric) 4000 kPa (Metric) |
| Resolution | 0.1 Psig 0.01 Bar 0.001 MPa 1 kPa 0.1 inHg 1 cmHg |
| Accuracy | 0 to 200 Psig: ±1 Psi 0 to 1378 KPa: ±7 KPa 0 to 1.378MPa: ±0.007MPa 0 to 13.78 bar: ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig) 1378 to 4000KPa: ±(0.3% ofreading+7 Kpa) 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa) 13.78 to 40.00bar: ±(0.3% of reading +0.07bar) |
| Maximum overload pressure | 800 Psig (5500 kPa) |
| Deep Vacuum | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | ange and Units: 50 to 9999 microns of mercury (English), 6.7 to 1330 Pascals (Metric), 0.067 to 13.30 mBar (Metric), 50 to 9999 mTorr (Metric), 0.050 to 9.999 Torr (Metric, equivalent to mmHg) |
| Resolution | 1 micron of mercury (below 2000 microns) 0.1 Pascal (below 250 Pascals) 0.001 mBar (below 2.500 mBar) 1 mTorr (below 2000 mTorr), 0.001 Torr (below 2.000 Torr) |
| Accuracy | ±(5% of reading + 5 microns of mercury), 50 to 1000 microns ±(5% of reading + 1.0 Pascal), 6.7 to 133.0 Pascal ±(5% of reading + 0.010 mBar), 0.067 to 1.330 mBar ±(5% of reading + 5 mTorr), 50 to 1000 mTorr ±(5% of reading + 0.005 Torr), 0.067 to 1.000 Torr |
| Maximum Overload pressure | 580 Psig (4000 kPa) |
| Temperature | |
| Sensor type | Type K thermocouple |
| Range | -50 to 257°F (-46 to 125°C) limited by the thermocouple specification. |
| Range | Display Range is -95 to 999.9°F (-70 to 537.0°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±(1.0°F): -95 to 200°F ±(0.5°C): -70 to 93°C ±(2.0°F) 200 to 999.9°F ±(1.0°C): 93 to 537.0°C |
| General Specifications | |
| Display size | 5" (diagonal) |
| Backlight | Blue (adjustable duration) |
| Radio Frequency | 2.4 GHz |
| Wireless Range | 1000 feet (305 meters) line of sightDistance decreases through obstructions |
| Micro-USB Port | For extracting logged data or updating firmware. |
| Battery | 6 x AA (Battery life below based on alkaline type) |
| Battery life | 350 hours (without vacuum, backlight, and wireless) |
| Low battery indication | Icon displayed when the battery voltage drops below the operating level |
| Auto Shut off | 30 minutes of inactivity (adjustable) |
| Operating environment | 32 to 122°F (0 to 50°C) at <75% relative humidity |
| Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% RH (with battery removed) |
| Temperature coefficient | 0.1 x (specified accuracy) Per °C: 0 to 18°C, 28 to 50°C Per 1.8°F: 32 to 64°F, 82 to 122°F |
| Over range | "OL" or "-OL" is displayed |
| Weight | 4.03 lbs (1.38 kg) |
| Water Resistant | Designed to IP54 |
Click on a category to view a selection of compatible accessories with the Fieldpiece SM380V SMAN 3-Port Digital Manifold Wireless Datalogging.
| Pressure | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | 580 Psig (English) 40.00 Bar (Metric) 4.000 MPa (Metric) 4000 kPa (Metric) |
| Resolution | 0.1 Psig 0.01 Bar 0.001 MPa 1 kPa 0.1 inHg 1 cmHg |
| Accuracy | 0 to 200 Psig: ±1 Psi 0 to 1378 KPa: ±7 KPa 0 to 1.378MPa: ±0.007MPa 0 to 13.78 bar: ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig) 1378 to 4000KPa: ±(0.3% ofreading+7 Kpa) 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa) 13.78 to 40.00bar: ±(0.3% of reading +0.07bar) |
| Maximum overload pressure | 800 Psig (5500 kPa) |
| Deep Vacuum | |
| Connector Type | Standard 1/4" NPT male flare fitting |
| Range | ange and Units: 50 to 9999 microns of mercury (English), 6.7 to 1330 Pascals (Metric), 0.067 to 13.30 mBar (Metric), 50 to 9999 mTorr (Metric), 0.050 to 9.999 Torr (Metric, equivalent to mmHg) |
| Resolution | 1 micron of mercury (below 2000 microns) 0.1 Pascal (below 250 Pascals) 0.001 mBar (below 2.500 mBar) 1 mTorr (below 2000 mTorr), 0.001 Torr (below 2.000 Torr) |
| Accuracy | ±(5% of reading + 5 microns of mercury), 50 to 1000 microns ±(5% of reading + 1.0 Pascal), 6.7 to 133.0 Pascal ±(5% of reading + 0.010 mBar), 0.067 to 1.330 mBar ±(5% of reading + 5 mTorr), 50 to 1000 mTorr ±(5% of reading + 0.005 Torr), 0.067 to 1.000 Torr |
| Maximum Overload pressure | 580 Psig (4000 kPa) |
| Temperature | |
| Sensor type | Type K thermocouple |
| Range | -50 to 257°F (-46 to 125°C) limited by the thermocouple specification. |
| Range | Display Range is -95 to 999.9°F (-70 to 537.0°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±(1.0°F): -95 to 200°F ±(0.5°C): -70 to 93°C ±(2.0°F) 200 to 999.9°F ±(1.0°C): 93 to 537.0°C |
| General Specifications | |
| Display size | 5" (diagonal) |
| Backlight | Blue (adjustable duration) |
| Radio Frequency | 2.4 GHz |
| Wireless Range | 1000 feet (305 meters) line of sightDistance decreases through obstructions |
| Micro-USB Port | For extracting logged data or updating firmware. |
| Battery | 6 x AA (Battery life below based on alkaline type) |
| Battery life | 350 hours (without vacuum, backlight, and wireless) |
| Low battery indication | Icon displayed when the battery voltage drops below the operating level |
| Auto Shut off | 30 minutes of inactivity (adjustable) |
| Operating environment | 32 to 122°F (0 to 50°C) at <75% relative humidity |
| Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% RH (with battery removed) |
| Temperature coefficient | 0.1 x (specified accuracy) Per °C: 0 to 18°C, 28 to 50°C Per 1.8°F: 32 to 64°F, 82 to 122°F |
| Over range | "OL" or "-OL" is displayed |
| Weight | 4.03 lbs (1.38 kg) |
| Water Resistant | Designed to IP54 |
Click on a category to view a selection of compatible accessories with the Fieldpiece SM380V SMAN 3-Port Digital Manifold Wireless Datalogging.