Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector

Model: DRX3 | UPC: 872641005603

Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector

Model: DRX3 | UPC: 872641005603

The all-in-one DRX3 handheld "sniffer" is used by HVAC/R technicians to locate leaks in refrigeration/AC systems and to spot-check for certain combustible/heating gases. One sensor quickly and accurately detects HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas), and blend refrigerants, as well as heating gases.

The all-in-one DRX3 handheld "sniffer" is used by HVAC/R technicians to locate leaks in refrigeration/AC systems and to spot-check for certain combustible/heating gases. One sensor quickly and accurately detects HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas), and blend refrigerants, as well as heating gases.

Sale Price $727.60 USD
Regular Price $856.00 USD
Availability 1 to 2 Weeks
Quantity

Fieldpiece DRX3 Offers

The lightweight DRX3 helps you locate system leaks quickly with multiple visual and audio feedback indicators that change with leak intensity and is designed for performance and safety, complying with ATEX Zone 2 and Class I, division 2 hazardous location requirements.

Features

  • Refrigerant families: HC, HFC, HCFC, CFC, HFO, blends, plus H₂/N₂ tracer gas (listed as 5% H₂ / 95% N₂ on the product specs)
  • Combustible/heating gases: Natural gas, propane, butane, methane
  • Safety class coverage for refrigerants: intended for A1, A2L, and A3 refrigerants
  • Auto and manual zero modes
  • High, medium and low sensitivity settings
  • Flashing red LED at the probe tip (blink rate increases with concentration)
  • Audible alarm changes with leak intensity
  • Backlit LCD shows bar graph and numeric “relative leak size” from 0–99 (relative units, not a calibrated ppm reading)
  • Single heated diode sensor is field-replaceable and has a typical life of about 300 hours (the tool tracks usage with a sensor-hours counter)
  • Long-life, field-replaceable batteries
  • Job Link® System App connected

Applications

HVAC and Refrigeration

Air Conditioner Refrigerant Leak Detection

  • Split systems, package units, VRF/VRV
  • Evaporator coils, condenser coils, flare joints, service ports

Heat Pump Systems

  • Checking indoor/outdoor coils and reversing valve connections

Commercial refrigeration equipment

  • Reach-in refrigerators & freezers
  • Walk-in coolers/freezers
  • Ice machines
  • Supermarket display cases

Automotive A/C Systems (where heated-diode sniffers are acceptable)

  • Hose fittings, compressors, condensers, evaporator drains

New Installation Verification

  • Checking all brazed joints and fittings after charging

Post-repair Leak Confirmation

  • Verifying sealed joints before evacuation and recharging

Flammable/Low-GWP Refrigerant Systems (A2L & A3)

R-32 Systems (A2L)

  • Mini-splits, residential heat pumps, light commercial units

R-1234yf Systems (A2L)

  • Automotive and specialty cooling equipment

Hydrocarbon Refrigerant Systems (A3)

  • R-290 (propane) refrigerators and freezers
  • R-600a (isobutane) domestic and light commercial units
  • Small sealed systems in food service and retail

Hydrogen/Nitrogen (5% H₂ / 95% N₂) Tracer Gas Systems

  • Pressure testing refrigeration and HVAC piping before charging
  • Locating very small leaks after installation or major repairs

Combustible Gas Detection (spot checking)

Natural Gas Line Leak Checks

  • Pipe joints, valves, regulators, appliance hookups

Propane System Checks

  • RV systems, food trucks, outdoor heaters, forklifts

Butane Leak Checks

  • Catering equipment, portable appliances, lab equipment

Industrial and Facility Maintenance

Mechanical Rooms and Plant Inspections

  • Periodic leak surveys around compressors, valves, and headers
  • Preventive Maintenance Programs
  • Finding small leaks early to reduce refrigerant loss and downtime

Commissioning of New Equipment

  • Final inspection before system handover

Fieldpiece DRX3 Specifications

Sensor Type: Heated diode
Life: 300 hours typical
Sensitivity Levels High, Medium, Low (selectable)
Maximum Sensitivity Stationary: 1g/yr (0.03 oz/yr)
In motion: 3g/yr (0.1 oz/yr)
Detection Feedback Flashing LED, LCD bar graph and digits, audible beep, Job Link® app
Refrigerants HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas: 5% Hydrogen, 95% Nitrogen), and blends
Heating Gases Natural Gas, Propane, Butane, Methane
For Use With A3 (R-290, R-600a, R-600, R-50, R-1270), A2L (Including R-32, R-454B, R-1234yf), and A1 refrigerants
Not For Use With R-702, R-717, R-744
Safety Compliance ATEX Zone 2(II 3 G Ex ic IIA T2 Gc); Class I, Division 2, Group D, T2 Hazardous Locations
Environmental Conditions Operating: -4 to 122°F (-20 to 50°C)
< 95% RH, non-condensing

Storage: -4 to 140°F (-20 to 60°C)
< 95% RH
Battery Type: 4 x replaceable AA Lithium Iron Disulfide (to maintain ATEX and CID2 compliance, use 4x Energizer L91 AA batteries.)
Capacity: 1.5 V DC (nominal) 3500 mAh
Life: 60 hours typical
Auto Power Off 10 minutes without detection or button press
Radio Frequency 2.4 GHz
Wireless Range Up to 656 feet (200 meters) line of sight
Water Resistance IP54 Main Body
Weight 15.6 oz (442 g), with batteries installed
Click here for complete specifications on the Fieldpiece DRX3

What's included with the Fieldpiece DRX3

  • Heated Diode Refrigerant Leak Detector – DRX3
  • Blow-Molded Case
  • Heated Diode Sensor – RXA3

Click on a category to view a selection of compatible accessories with the Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector.

Fieldpiece RXA3 A3 Replacement Heated Diode Sensor Tip for the DRX3 gas leak detector RXA3
Engineered for consistent detection accuracy, this field-replaceable sensor tip is compatible with the DRX3 refrigerant and combustible gas leak detector. In addition, to maintain optimal performance and reliability, replacement is recommended after approximately 300 hours of use, depending on gas exposure.




Ask a question about Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector

Customer Reviews for the Fieldpiece DRX3

Fieldpiece DRX3 Offers

The lightweight DRX3 helps you locate system leaks quickly with multiple visual and audio feedback indicators that change with leak intensity and is designed for performance and safety, complying with ATEX Zone 2 and Class I, division 2 hazardous location requirements.

Features

  • Refrigerant families: HC, HFC, HCFC, CFC, HFO, blends, plus H₂/N₂ tracer gas (listed as 5% H₂ / 95% N₂ on the product specs)
  • Combustible/heating gases: Natural gas, propane, butane, methane
  • Safety class coverage for refrigerants: intended for A1, A2L, and A3 refrigerants
  • Auto and manual zero modes
  • High, medium and low sensitivity settings
  • Flashing red LED at the probe tip (blink rate increases with concentration)
  • Audible alarm changes with leak intensity
  • Backlit LCD shows bar graph and numeric “relative leak size” from 0–99 (relative units, not a calibrated ppm reading)
  • Single heated diode sensor is field-replaceable and has a typical life of about 300 hours (the tool tracks usage with a sensor-hours counter)
  • Long-life, field-replaceable batteries
  • Job Link® System App connected

Applications

HVAC and Refrigeration

Air Conditioner Refrigerant Leak Detection

  • Split systems, package units, VRF/VRV
  • Evaporator coils, condenser coils, flare joints, service ports

Heat Pump Systems

  • Checking indoor/outdoor coils and reversing valve connections

Commercial refrigeration equipment

  • Reach-in refrigerators & freezers
  • Walk-in coolers/freezers
  • Ice machines
  • Supermarket display cases

Automotive A/C Systems (where heated-diode sniffers are acceptable)

  • Hose fittings, compressors, condensers, evaporator drains

New Installation Verification

  • Checking all brazed joints and fittings after charging

Post-repair Leak Confirmation

  • Verifying sealed joints before evacuation and recharging

Flammable/Low-GWP Refrigerant Systems (A2L & A3)

R-32 Systems (A2L)

  • Mini-splits, residential heat pumps, light commercial units

R-1234yf Systems (A2L)

  • Automotive and specialty cooling equipment

Hydrocarbon Refrigerant Systems (A3)

  • R-290 (propane) refrigerators and freezers
  • R-600a (isobutane) domestic and light commercial units
  • Small sealed systems in food service and retail

Hydrogen/Nitrogen (5% H₂ / 95% N₂) Tracer Gas Systems

  • Pressure testing refrigeration and HVAC piping before charging
  • Locating very small leaks after installation or major repairs

Combustible Gas Detection (spot checking)

Natural Gas Line Leak Checks

  • Pipe joints, valves, regulators, appliance hookups

Propane System Checks

  • RV systems, food trucks, outdoor heaters, forklifts

Butane Leak Checks

  • Catering equipment, portable appliances, lab equipment

Industrial and Facility Maintenance

Mechanical Rooms and Plant Inspections

  • Periodic leak surveys around compressors, valves, and headers
  • Preventive Maintenance Programs
  • Finding small leaks early to reduce refrigerant loss and downtime

Commissioning of New Equipment

  • Final inspection before system handover

Fieldpiece DRX3 Specifications

Sensor Type: Heated diode
Life: 300 hours typical
Sensitivity Levels High, Medium, Low (selectable)
Maximum Sensitivity Stationary: 1g/yr (0.03 oz/yr)
In motion: 3g/yr (0.1 oz/yr)
Detection Feedback Flashing LED, LCD bar graph and digits, audible beep, Job Link® app
Refrigerants HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas: 5% Hydrogen, 95% Nitrogen), and blends
Heating Gases Natural Gas, Propane, Butane, Methane
For Use With A3 (R-290, R-600a, R-600, R-50, R-1270), A2L (Including R-32, R-454B, R-1234yf), and A1 refrigerants
Not For Use With R-702, R-717, R-744
Safety Compliance ATEX Zone 2(II 3 G Ex ic IIA T2 Gc); Class I, Division 2, Group D, T2 Hazardous Locations
Environmental Conditions Operating: -4 to 122°F (-20 to 50°C)
< 95% RH, non-condensing

Storage: -4 to 140°F (-20 to 60°C)
< 95% RH
Battery Type: 4 x replaceable AA Lithium Iron Disulfide (to maintain ATEX and CID2 compliance, use 4x Energizer L91 AA batteries.)
Capacity: 1.5 V DC (nominal) 3500 mAh
Life: 60 hours typical
Auto Power Off 10 minutes without detection or button press
Radio Frequency 2.4 GHz
Wireless Range Up to 656 feet (200 meters) line of sight
Water Resistance IP54 Main Body
Weight 15.6 oz (442 g), with batteries installed
Click here for complete specifications on the Fieldpiece DRX3

What's included with the Fieldpiece DRX3

  • Heated Diode Refrigerant Leak Detector – DRX3
  • Blow-Molded Case
  • Heated Diode Sensor – RXA3

Click on a category to view a selection of compatible accessories with the Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector.

Fieldpiece RXA3 A3 Replacement Heated Diode Sensor Tip for the DRX3 gas leak detector RXA3
Engineered for consistent detection accuracy, this field-replaceable sensor tip is compatible with the DRX3 refrigerant and combustible gas leak detector. In addition, to maintain optimal performance and reliability, replacement is recommended after approximately 300 hours of use, depending on gas exposure.




Ask a question about Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector

Customer Reviews for the Fieldpiece DRX3

More Fieldpiece Products