CAT85K2 is an innovative residential/commercial combustion analyzer with a printer for HVAC/R professionals to assess heating systems, draft pressure, and temperatures to support the overall fuel efficiency and safety of furnaces. This analyzer accurately measures O2, CO, CO2, flue temperature, air temperature, and draft/gas pressure. Fieldpiece's combustion analyzer with improved combustion analysis through optimized thermal processes helps technicians assess and monitor combustion data during installation, maintenance, and repairs. The CAT85K2 includes a wireless printer.
CAT85K2 is an innovative residential/commercial combustion analyzer with a printer for HVAC/R professionals to assess heating systems, draft pressure, and temperatures to support the overall fuel efficiency and safety of furnaces. This analyzer accurately measures O2, CO, CO2, flue temperature, air temperature, and draft/gas pressure. Fieldpiece's combustion analyzer with improved combustion analysis through optimized thermal processes helps technicians assess and monitor combustion data during installation, maintenance, and repairs. The CAT85K2 includes a wireless printer.
The CAT85K2 flue analyzer features Fieldpiece patent pending SensorVault™ technology that offers a lower cost of ownership. This patent pending feature extends sensor life by sealing the sensor from oxygen in the air during storage. These sensors are warrantied for four years and are field replaceable.
A built-in dual-port manometer is included on the Fieldpiece CAT85K2 commercial combustion analyzer to measure gas pressures, a gas regulator operation, and even measure total external static pressure of a heating appliance.
The CAT85K2 also features live draft pressure measurements allowing the HVAC Professional to view the effects adjustments have on the draft pressure in real-time.
The patent pending HydroCycle™ Pump technology is included on Fieldpiece CAT85K2 flue probe that automatically separates and returns accumulated water to the flue.
The Fieldpiece CAT85K2 utilizes a convenient one-touch power on-button; pressing the power button initializes the short start-up period and unlocks the new SensorVault™ technology. The combustion testing starts automatically after the startup is complete.
The Fieldpiece combustion analyzer is intuitive, user-friendly, and makes data simple to scan. HVAC professionals will appreciate the clear view of all information on a single screen, the easy-to-navigate touchscreen display design, and the simple user interface.
The CAT85K2 combustion analyzer features a large, high-contrast 5.5” touchscreen display for viewing measurements. Save your customer data with dedicated fields for client information, and a live trend report is available with O2, CO, and CO2 readings, for more advanced diagnosis.
The Fieldpiece combustion analyzer is designed to handle the rigors of any job site with its thick over-molded construction, a long flexible hose/cord, and a padded hardline carrying case with multiple inserts for accessories. Plus, the magnetic back lets you work hands-free. The combustion analyzer comes with a rechargeable battery that lasts up to seven hours and enables charges in trucks between jobs and overnight.
The CAT85K2 is compatible with the Fieldpiece Job Link System App featuring its industry-leading 1000-foot wireless range. The Fieldpiece Job Link App allows technicians to view trends, draft pressure, and customer details seamlessly and conveniently.
A wireless printer (CATPR) is included with the Fieldpiece CAT85K2 for jobsites that require documentation printouts. If you would like the combustion analyzer without a printer, check out the Fieldpiece CAT85.
Features
Top 5 Reasons to Own Fieldpiece CAT85 Combustion Analyzer:
Applications
Sensors | |
Temperature | Type K rod thermocouple (fixed), < 30 seconds (T90) |
Oxygen % | Electrochemical (replaceable), < 30 seconds (T90), 30% Oxygen |
Carbon Monoxide PPM | Electrochemical (replaceable), < 90 seconds (T90), 10000 ppm Carbon Monoxide |
Pressure (Probe) | Piezoresistive pressure sensor, < 10 seconds (T90), 4.0 inWC will cause damage |
Pressure (Ports) | Silicon pressure sensors, < 10 seconds (T90), 11.6 psig (321 inWC) causes damage |
Test Parameters | |
Stack Temperature | 0.1°F (0.1°C): 32 to 752°F (0 to 400°C) ±2.5°F: 32 to 212°F ±(3.6°F or 1.5%rdg): 213 to 752°F ±1.4°C: 0 to 100°C ±(2.0°C or 1.5%rdg): 101 to 400°C |
Oxygen O2 | 0 to 21 vol.%, 0.1 vol.%, ±0.3 vol.% |
Carbon Monoxide CO | 0 to 4000 ppm, 1 ppm, ±20 ppm [0 to 400 ppm], ±5%rdg [401 to 2000 ppm], ±10%rdg [2001 to 4000 ppm] |
Draft Pressure | 0 to ±0.8 inWC, 0.01 inWC, ±0.02 inWC |
CO Air Free (Calculated) | 0 to 4000 ppm, 1 ppm |
CO2 (Calculated) | 0 to CO2max vol.%, 0.1 vol.% |
Excess Air (Calculated) | 0 to 999%, ±0.1 vol.% |
Efficiency (Calculated) | 0 to 100%, 0.1% |
qA (Calculated) | 0 to 25%, 0.1% |
Dew Point (Calculated) | 32 to 212°F; 0 to 100°C, 0.1°F; 0.1°C |
Primary Air Temp | 0.1°F (0.1°C): 32 to 212°F (0 to 100°C) ±2.5°F: 32 to 212°F ±1.4°C: 0 to 100°C |
Ambient CO | 0 to 200 ppm, 1 ppm, ±20 ppm |
Manometer | 0.01 inWC: 0 to ±40 inWC ±0.2 inWC: 0 to ±20 inWC ±1%rdg: ±(20.1 to 40.0 inWC) |
Fuel Pressures | 0.01 inWC: 0 to 40 inWC ±0.2 inWC: 0 to 20 inWC ±1%rdg: 20.1 to 40.0 inWC |
General Technical Data | |
Display | Touchscreen TFT LCD (5.5 in diagonal) |
Probe Size | 10.7 in (272 mm) length, 0.32 in (8.0 mm) diameter |
Accuracy | Stated accuracies at 23°C ±5°C, <75% R.H. |
Battery Type | 3.7 VDC (nominal), 6400mAh, non-replaceable |
Battery Life | 7 hours typical (pump running 80% of the time) |
Charge Time | < 7 hours typical at 5V/2A DC power |
Charging Port | USB-C (Usable when connected to power.) |
Memory | 1000 jobs (approx.) |
Warm Up Time | 45 seconds (90 seconds near freezing) |
Operating Environment | 14°F to 104°F (-10°C to 40°C); < 75% RH (non-condensing) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C); < 80% RH |
Weight | 39.5 oz (1120 g) with probe |
Wireless Range | 1000 feet (305 meters) |
Fuel Types | Natural Gas, Propane (LPG), Oil #2 (Light), Oil #6 (Heavy), Biofuel, Coal, Coal Town Gas, Coking Oven Gas, KOKS, Custom (x3) |
Warranty | 1 year (4 years sensors only) |
Job Link® System Minimum | BLE 4.0 devices running iOS 7.1 or Android™ Kitkat 4.4 |
Printer | Fieldpiece Wireless Thermal Printer (model CATPR) (not included) |
Certifications | FCC ID: 2ALHRCATX5, IC: Industry Canada, IC: 22518-CATX5, Waste Electrical and Electronic Equipment |
Thermal Printer - CATPR | |
Print technology | Direct thermal |
Paper type | Thermal paper roll |
Paper width | 2.25" (58mm) |
Paper diameter | 2" (50mm) max, 0.35" (9mm) min |
Paper thickness | 0.06 to 0.08mm |
Print width | 1.9" (48mm) |
Resolution | 203 DPI |
Print speed max | 2.25"/sec (60mm/sec) |
Interface | USB+Bluetooth 3.0/BLE 4.0 |
Charging Port | DC 5V-1A |
Lithium battery | 2200mAh 7.4V |
Battery Life | 7 days (standby) |
Printer weight | 0.57 lbs 256 g (includes battery) |
Printer dimensions | 5" (W) x 3.43" (L) x 2.4" (D) 127mm (W) x 87mm (L) x 61mm (D) |
Operating environment | 41°F to 131°F (5°C to 55°C), 20 to 90% RH |
Storage temperature | -13°F to 131°F (-25°C to 55°C), 20 to 93% RH |
Click on a category to view a selection of compatible accessories with the Fieldpiece CAT85K2 Combustion Analyzer Printer Kit with HydroCycle.
Sensors | |
Temperature | Type K rod thermocouple (fixed), < 30 seconds (T90) |
Oxygen % | Electrochemical (replaceable), < 30 seconds (T90), 30% Oxygen |
Carbon Monoxide PPM | Electrochemical (replaceable), < 90 seconds (T90), 10000 ppm Carbon Monoxide |
Pressure (Probe) | Piezoresistive pressure sensor, < 10 seconds (T90), 4.0 inWC will cause damage |
Pressure (Ports) | Silicon pressure sensors, < 10 seconds (T90), 11.6 psig (321 inWC) causes damage |
Test Parameters | |
Stack Temperature | 0.1°F (0.1°C): 32 to 752°F (0 to 400°C) ±2.5°F: 32 to 212°F ±(3.6°F or 1.5%rdg): 213 to 752°F ±1.4°C: 0 to 100°C ±(2.0°C or 1.5%rdg): 101 to 400°C |
Oxygen O2 | 0 to 21 vol.%, 0.1 vol.%, ±0.3 vol.% |
Carbon Monoxide CO | 0 to 4000 ppm, 1 ppm, ±20 ppm [0 to 400 ppm], ±5%rdg [401 to 2000 ppm], ±10%rdg [2001 to 4000 ppm] |
Draft Pressure | 0 to ±0.8 inWC, 0.01 inWC, ±0.02 inWC |
CO Air Free (Calculated) | 0 to 4000 ppm, 1 ppm |
CO2 (Calculated) | 0 to CO2max vol.%, 0.1 vol.% |
Excess Air (Calculated) | 0 to 999%, ±0.1 vol.% |
Efficiency (Calculated) | 0 to 100%, 0.1% |
qA (Calculated) | 0 to 25%, 0.1% |
Dew Point (Calculated) | 32 to 212°F; 0 to 100°C, 0.1°F; 0.1°C |
Primary Air Temp | 0.1°F (0.1°C): 32 to 212°F (0 to 100°C) ±2.5°F: 32 to 212°F ±1.4°C: 0 to 100°C |
Ambient CO | 0 to 200 ppm, 1 ppm, ±20 ppm |
Manometer | 0.01 inWC: 0 to ±40 inWC ±0.2 inWC: 0 to ±20 inWC ±1%rdg: ±(20.1 to 40.0 inWC) |
Fuel Pressures | 0.01 inWC: 0 to 40 inWC ±0.2 inWC: 0 to 20 inWC ±1%rdg: 20.1 to 40.0 inWC |
General Technical Data | |
Display | Touchscreen TFT LCD (5.5 in diagonal) |
Probe Size | 10.7 in (272 mm) length, 0.32 in (8.0 mm) diameter |
Accuracy | Stated accuracies at 23°C ±5°C, <75% R.H. |
Battery Type | 3.7 VDC (nominal), 6400mAh, non-replaceable |
Battery Life | 7 hours typical (pump running 80% of the time) |
Charge Time | < 7 hours typical at 5V/2A DC power |
Charging Port | USB-C (Usable when connected to power.) |
Memory | 1000 jobs (approx.) |
Warm Up Time | 45 seconds (90 seconds near freezing) |
Operating Environment | 14°F to 104°F (-10°C to 40°C); < 75% RH (non-condensing) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C); < 80% RH |
Weight | 39.5 oz (1120 g) with probe |
Wireless Range | 1000 feet (305 meters) |
Fuel Types | Natural Gas, Propane (LPG), Oil #2 (Light), Oil #6 (Heavy), Biofuel, Coal, Coal Town Gas, Coking Oven Gas, KOKS, Custom (x3) |
Warranty | 1 year (4 years sensors only) |
Job Link® System Minimum | BLE 4.0 devices running iOS 7.1 or Android™ Kitkat 4.4 |
Printer | Fieldpiece Wireless Thermal Printer (model CATPR) (not included) |
Certifications | FCC ID: 2ALHRCATX5, IC: Industry Canada, IC: 22518-CATX5, Waste Electrical and Electronic Equipment |
Thermal Printer - CATPR | |
Print technology | Direct thermal |
Paper type | Thermal paper roll |
Paper width | 2.25" (58mm) |
Paper diameter | 2" (50mm) max, 0.35" (9mm) min |
Paper thickness | 0.06 to 0.08mm |
Print width | 1.9" (48mm) |
Resolution | 203 DPI |
Print speed max | 2.25"/sec (60mm/sec) |
Interface | USB+Bluetooth 3.0/BLE 4.0 |
Charging Port | DC 5V-1A |
Lithium battery | 2200mAh 7.4V |
Battery Life | 7 days (standby) |
Printer weight | 0.57 lbs 256 g (includes battery) |
Printer dimensions | 5" (W) x 3.43" (L) x 2.4" (D) 127mm (W) x 87mm (L) x 61mm (D) |
Operating environment | 41°F to 131°F (5°C to 55°C), 20 to 90% RH |
Storage temperature | -13°F to 131°F (-25°C to 55°C), 20 to 93% RH |
Click on a category to view a selection of compatible accessories with the Fieldpiece CAT85K2 Combustion Analyzer Printer Kit with HydroCycle.