Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C

Model: TH30 | UPC: 793950422304

Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C

Model: TH30 | UPC: 793950422304

Easy-to-use datalogger records air temperature and external probe temperature with date/time stamp. Designed with a rugged housing and a USB connector where you can transfer the stored readings to a PC.

Easy-to-use datalogger records air temperature and external probe temperature with date/time stamp. Designed with a rugged housing and a USB connector where you can transfer the stored readings to a PC.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Temperature Data Loggers category for similar products.

Or let's do a search and help you find what you need:


Extech TH30 Offers

Features

  • Compact size housing with built-in NTC thermistor and external temperature probe designed with standard USB connector for easy data downloading to a PC
  • 5-digit LCD display with battery life indicator
  • Meets ANSI Type 2 and EN 60651 accuracy specs compliant to OSHA
  • User programmable settings: 6 languages, sample rate, start delay time, alarm delay time, high/low alarm range, and security feature
  • Status Indication via Red and Green LEDs
  • Start button begins continuous datalogging, which continues until memory is full at 48,000 readings (24,000 for each parameter: T1 and T2), or when Stop button is pressed
  • Bookmark 8 locations in a data recording log with a press of the Mark button
  • Long battery life (approx. 3 months)
  • Generates a PDF report or Excel® spreadsheet with data and trending graph when plugged into a PC after datalogging is completed (Adobe Reader® required)
  • Max/Min function

Extech TH30 Specifications

Temperature (Probe and Air)

22 to 158°F (-30 to 70°C)

Max Resolution

0.1°

Basic accuracy

±1.0°F (±0.5°C)

Datalogging interval

30 seconds to 2 hours

Memory

Air Temperature (T1): 24,000 data; External Probe Temperature (T2): 24,000 data

Dimensions/ Weight

4.3x1.6x0.75" (110x40x19mm)/ 1oz (90g)

Click here for complete specifications on the Extech TH30

What's included with the Extech TH30

  • Extech TH30 USB Dual Temperature Datalogger
  • USB cover (can be used as a stand)
  • TP830 probe
  • built-in hanger
  • CR2032 batteries (x2)

Click on a category to view a selection of compatible accessories with the Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C.

Extech TP830 Thermistor Probe, Stainless Steel TP830
Stainless Steel Thermistor Probe with 39" (1m) cable for the TH30 Datalogger.




Extech TP832 Thermistor Probe, Stainless Steel with Handle TP832
Stainless Steel Thermistor Probe with handle and 43" (1.1m) cable for the TH30 Datalogger.




Ask a question about Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C

Customer Reviews for the Extech TH30

Extech TH30 Offers

Features

  • Compact size housing with built-in NTC thermistor and external temperature probe designed with standard USB connector for easy data downloading to a PC
  • 5-digit LCD display with battery life indicator
  • Meets ANSI Type 2 and EN 60651 accuracy specs compliant to OSHA
  • User programmable settings: 6 languages, sample rate, start delay time, alarm delay time, high/low alarm range, and security feature
  • Status Indication via Red and Green LEDs
  • Start button begins continuous datalogging, which continues until memory is full at 48,000 readings (24,000 for each parameter: T1 and T2), or when Stop button is pressed
  • Bookmark 8 locations in a data recording log with a press of the Mark button
  • Long battery life (approx. 3 months)
  • Generates a PDF report or Excel® spreadsheet with data and trending graph when plugged into a PC after datalogging is completed (Adobe Reader® required)
  • Max/Min function

Extech TH30 Specifications

Temperature (Probe and Air)

22 to 158°F (-30 to 70°C)

Max Resolution

0.1°

Basic accuracy

±1.0°F (±0.5°C)

Datalogging interval

30 seconds to 2 hours

Memory

Air Temperature (T1): 24,000 data; External Probe Temperature (T2): 24,000 data

Dimensions/ Weight

4.3x1.6x0.75" (110x40x19mm)/ 1oz (90g)

Click here for complete specifications on the Extech TH30

What's included with the Extech TH30

  • Extech TH30 USB Dual Temperature Datalogger
  • USB cover (can be used as a stand)
  • TP830 probe
  • built-in hanger
  • CR2032 batteries (x2)

Click on a category to view a selection of compatible accessories with the Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C.

Extech TP830 Thermistor Probe, Stainless Steel TP830
Stainless Steel Thermistor Probe with 39" (1m) cable for the TH30 Datalogger.




Extech TP832 Thermistor Probe, Stainless Steel with Handle TP832
Stainless Steel Thermistor Probe with handle and 43" (1.1m) cable for the TH30 Datalogger.




Ask a question about Extech TH30 USB Dual Temperature Datalogger, -30 to 70°C

Customer Reviews for the Extech TH30

More Extech Products