Datalogging Sound Level Meter - Type 2 meter with datalogging memory for 128,000 records plus PC interface and software
Datalogging Sound Level Meter - Type 2 meter with datalogging memory for 128,000 records plus PC interface and software
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
General Specifications | |
Applicable Standards | IEC651 Type 2 ANSI S1.4 Type 2 |
Accuracy | ±1.5dB (under reference conditions) |
Frequency range | 31.5Hz - 8KHz |
Measuring level | 30 - 130dB |
Frequency weighting | A and C |
Microphone | 0.5” Electret condenser microphone |
Display | 4-digit LCD |
Resolution | 0.1dB |
Display period | 0.5 sec. |
Bargraph | 50dB scale (1dB steps). Display period: 50mS; Auto-ranging: 100dB scale 2dB steps |
Sampling rate | 50mS |
Memory size | 16000 records / 255 sets (non-volatile memory) |
Datalogging sample rate | 1 to 86400 seconds per record |
Time weighting | FAST: 125mS SLOW: 1 sec. |
MAX | Maximum reading held |
Level ranges | 30-80dB 40-90dB 50-100dB 60-110 dB 70-120dB 80-130dB(Total of 6 ranges) |
Auto range | 30 to 130dB |
Linearity range | 50dB |
Alarm function | OVER indicator for readings higher than high limit. UNDER indicator for readings lower than low limit. |
AC output | 0.707 Vrms at Full Scale |
Output impedance | approx. 600 Ω |
DC output | 10mV / dB |
Output impedance | approx. 100 Ω |
Power supply | Four 1.5V ‘AA’ batteries |
Battery life | Approx. 30 hrs continuous operation |
AC adapter Voltage | 6VDC |
Voltage Ripple | < 100mVpp |
Supply Current | > 100mADC |
Socket | Pin Ground |
Casing | Positive |
External Diameter | 3.5mm |
Operating temperature | 32 to 104°F (0 to 40°C) |
Operating humidity | 10 to 80%RH |
Storage temperature | 14 to 140°F (-10 to 60°C) |
Storage humidity | 10 to 80%RH |
Memory size | 16000 data records with Date and Time Stamping |
RS-232 Interface Baud rate | 9600bps |
Dimensions | 10.4 x 2.8 x 1.4” (265 × 72 × 35mm |
Weight | Approx. 11.5 oz. (358g) including battery |
Accessories | Batteries carrying case screwdriver windscreen 3.5mm plug RS-232cable 9- to 25-pin gender changer Windows compatible software. |
General Specifications | |
Applicable Standards | IEC651 Type 2 ANSI S1.4 Type 2 |
Accuracy | ±1.5dB (under reference conditions) |
Frequency range | 31.5Hz - 8KHz |
Measuring level | 30 - 130dB |
Frequency weighting | A and C |
Microphone | 0.5” Electret condenser microphone |
Display | 4-digit LCD |
Resolution | 0.1dB |
Display period | 0.5 sec. |
Bargraph | 50dB scale (1dB steps). Display period: 50mS; Auto-ranging: 100dB scale 2dB steps |
Sampling rate | 50mS |
Memory size | 16000 records / 255 sets (non-volatile memory) |
Datalogging sample rate | 1 to 86400 seconds per record |
Time weighting | FAST: 125mS SLOW: 1 sec. |
MAX | Maximum reading held |
Level ranges | 30-80dB 40-90dB 50-100dB 60-110 dB 70-120dB 80-130dB(Total of 6 ranges) |
Auto range | 30 to 130dB |
Linearity range | 50dB |
Alarm function | OVER indicator for readings higher than high limit. UNDER indicator for readings lower than low limit. |
AC output | 0.707 Vrms at Full Scale |
Output impedance | approx. 600 Ω |
DC output | 10mV / dB |
Output impedance | approx. 100 Ω |
Power supply | Four 1.5V ‘AA’ batteries |
Battery life | Approx. 30 hrs continuous operation |
AC adapter Voltage | 6VDC |
Voltage Ripple | < 100mVpp |
Supply Current | > 100mADC |
Socket | Pin Ground |
Casing | Positive |
External Diameter | 3.5mm |
Operating temperature | 32 to 104°F (0 to 40°C) |
Operating humidity | 10 to 80%RH |
Storage temperature | 14 to 140°F (-10 to 60°C) |
Storage humidity | 10 to 80%RH |
Memory size | 16000 data records with Date and Time Stamping |
RS-232 Interface Baud rate | 9600bps |
Dimensions | 10.4 x 2.8 x 1.4” (265 × 72 × 35mm |
Weight | Approx. 11.5 oz. (358g) including battery |
Accessories | Batteries carrying case screwdriver windscreen 3.5mm plug RS-232cable 9- to 25-pin gender changer Windows compatible software. |