This explosion-proof RTD temperature transmitter offers a 12" (30 cm) probe, NEMA 4X and IP66 enclosure, and an LCD display for high-pressure process measuring. It includes seven selectable ranges via an internal dip switch and can be configured from -29 to 250°F (-33.9 to 121°C), minimum 40°F (4.4°C) span. Ideal for technicians and engineers requiring safe, accurate temperature measurement in hazardous areas.

This explosion-proof RTD temperature transmitter offers a 12" (30 cm) probe, NEMA 4X and IP66 enclosure, and an LCD display for high-pressure process measuring. It includes seven selectable ranges via an internal dip switch and can be configured from -29 to 250°F (-33.9 to 121°C), minimum 40°F (4.4°C) span. Ideal for technicians and engineers requiring safe, accurate temperature measurement in hazardous areas.

Sale Price $936.73 USD
Regular Price $1023.75 USD
Availability 2 to 3 Weeks
Quantity

Dwyer TTE-112-W-LCD Offers

Features

  • FM approved for Class I, Groups B, C, D; Class II, Groups E, F, G classified explosive environments
  • Optional LCD
  • Output span selected from seven common ranges or user determined

Applications

  • Boilers
  • Oil
  • Refrigeration
  • Refrigeration Equipment
  • Explosive process environments
  • Offshore HVAC/R monitoring

Dwyer TTE-112-W-LCD Specifications

Transmitter Accuracy Transmitter: ± 0.1%
Probe: ± 0.3%
Construction Type Well Probe
Current Output 4 to 20 mA
Electrical Connection 1/2" (12.7 mm) NPT female conduit with screw terminal block
Enclosure Ratings: Hazardous location rated
Enclosure Ratings Note Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1, Groups E, F and G and Class III atmospheres. ATEX Certified: 2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. EUtype Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. IECEx Certified: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31. UKCA Ex Certified for: 0518 II 2 G Ex db IIC T6...T4 Gb/II 1 D Ex ta IIIC T111°C Da, T6 process temp ≤ 80°C, T5 process temp ≤ 95°C, T4 process temp ≤ 120°C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
Gross Weight Value 0.1
Thermal Effects ± 0.02%/°C max
Input Note User selectable – any range between -30 to 250°F with a minimum span of 40°F FIELD-SELECTABLE RANGES 40 to 90°F (4.4 to 32.2°C) -20 to 140°F (-28.9 to 60°C) 0 to 100°F (-17.8 to 37.8°C) 30 to 240°F (-1.1 to 115.6°C) 32 to 212°F (0 to 100°C) 32 to 122°F (0 to 50°C) -30 to 65°C (-1.1 to 18.3°C) Custom range between -30 to 250°F (-34.4 to 121.1°C)
Wetted Materials 316 Stainless Steel
Measurement Type RTD
Number of Wires 2
Operating Temperature Maximum: 158°F (70°C)
Minimum: -4°F (-20°C)
Output Detail: 4 to 20 mA (2-wire loop powered)
Signal: Current
Pressure Limits Up to 2000 psi
Probe Length 12" (30 cm)
Process Connection Size 1/2" (12.7 mm)
Process Connection Type NPT Male
Process Temperature Maximum: 250°F (121.1°C)
Minimum: -30°F (-34.4°C)
Protection Explosion-Proof
Response Time 250 ms
Sensor Type Pt1000
Series ID Series-TTE
Power 10 to 35 V DC
Country of Origin United States
Weight 2.5 lbs (1134 g)

What's included with the Dwyer TTE-112-W-LCD

  • Dwyer TTE-112-W-LCD Temperature Transmitter, RTD, 12" probe, explosion-proof

Ask a question about Dwyer TTE-112-W-LCD Temperature Transmitter, RTD, 12" probe, explosion-proof

Customer Reviews for the Dwyer TTE-112-W-LCD

Dwyer TTE-112-W-LCD Offers

Features

  • FM approved for Class I, Groups B, C, D; Class II, Groups E, F, G classified explosive environments
  • Optional LCD
  • Output span selected from seven common ranges or user determined

Applications

  • Boilers
  • Oil
  • Refrigeration
  • Refrigeration Equipment
  • Explosive process environments
  • Offshore HVAC/R monitoring

Dwyer TTE-112-W-LCD Specifications

Transmitter Accuracy Transmitter: ± 0.1%
Probe: ± 0.3%
Construction Type Well Probe
Current Output 4 to 20 mA
Electrical Connection 1/2" (12.7 mm) NPT female conduit with screw terminal block
Enclosure Ratings: Hazardous location rated
Enclosure Ratings Note Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1, Groups E, F and G and Class III atmospheres. ATEX Certified: 2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. EUtype Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. IECEx Certified: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31. UKCA Ex Certified for: 0518 II 2 G Ex db IIC T6...T4 Gb/II 1 D Ex ta IIIC T111°C Da, T6 process temp ≤ 80°C, T5 process temp ≤ 95°C, T4 process temp ≤ 120°C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
Gross Weight Value 0.1
Thermal Effects ± 0.02%/°C max
Input Note User selectable – any range between -30 to 250°F with a minimum span of 40°F FIELD-SELECTABLE RANGES 40 to 90°F (4.4 to 32.2°C) -20 to 140°F (-28.9 to 60°C) 0 to 100°F (-17.8 to 37.8°C) 30 to 240°F (-1.1 to 115.6°C) 32 to 212°F (0 to 100°C) 32 to 122°F (0 to 50°C) -30 to 65°C (-1.1 to 18.3°C) Custom range between -30 to 250°F (-34.4 to 121.1°C)
Wetted Materials 316 Stainless Steel
Measurement Type RTD
Number of Wires 2
Operating Temperature Maximum: 158°F (70°C)
Minimum: -4°F (-20°C)
Output Detail: 4 to 20 mA (2-wire loop powered)
Signal: Current
Pressure Limits Up to 2000 psi
Probe Length 12" (30 cm)
Process Connection Size 1/2" (12.7 mm)
Process Connection Type NPT Male
Process Temperature Maximum: 250°F (121.1°C)
Minimum: -30°F (-34.4°C)
Protection Explosion-Proof
Response Time 250 ms
Sensor Type Pt1000
Series ID Series-TTE
Power 10 to 35 V DC
Country of Origin United States
Weight 2.5 lbs (1134 g)

What's included with the Dwyer TTE-112-W-LCD

  • Dwyer TTE-112-W-LCD Temperature Transmitter, RTD, 12" probe, explosion-proof

Ask a question about Dwyer TTE-112-W-LCD Temperature Transmitter, RTD, 12" probe, explosion-proof

Customer Reviews for the Dwyer TTE-112-W-LCD

More Dwyer Products