Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% RH accuracy

Model: RHPX-2SDA0-00-LCD

Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% RH accuracy

Model: RHPX-2SDA0-00-LCD

Precisely monitors humidity and temperature for building control functions to optimize occupant comfort and minimize operating costs. Features a small enclosure, duct mount sensor configuration, selectable analog output and LCD display.

Precisely monitors humidity and temperature for building control functions to optimize occupant comfort and minimize operating costs. Features a small enclosure, duct mount sensor configuration, selectable analog output and LCD display.

Sale Price $284.34 USD
Regular Price $310.75 USD
Availability 2 to 3 Weeks
Quantity

Dwyer RHPX-2SDA0-00-LCD Offers

Equipped with capacitance polymer humidity sensors, the RHPX-2SDA0-00-LCD offers ±2% accuracy. Features a duct mount with plenum plastic probe and hydrophobic filter sensor configuration, selectable analog output, and two-line alphanumeric LCD display. With high accuracy, long-term stability, and reliable operation in various enclosure styles, the RHPX is ideal for building energy management systems, commercial HVAC systems, clean rooms, museums, and data centers. It can also be configured to provide absolute or relative humidity, dew point, or enthalpy.

Features

  • Reduced installation costs with multiple on-board sensors
  • Minimal maintenance with UV rated outdoor enclosures
  • UL 2043 compliant allows installation into the plenum space
  • Intrinsically safe hazardous area versions.
  • Easy installation with removable terminal block, attached lid, and cable management

Applications

  • Air economizers
  • Outdoor humidity and temperature reference
  • Pool room humidity monitoring
  • Building energy management systems
  • Commercial HVAC systems
  • Clean rooms
  • Museums
  • Data centers

Dwyer RHPX-2SDA0-00-LCD Specifications

Humidity Measurement Range 0% to 100% humidity.
Temperature Measurement Range -40 to 60°C (-40 to 140°F)
Humidity Sensor Accuracy ±2 % at 10 % - 90 % RH and 25 °C (77°F)
Temperature Sensor Accuracy, Solid State Band Gap: ±0.9°F (±0.5°C at 25°C)
Temperature Sensor Accuracy, Thermistor: ±0.2°C at 25°C (±0.36°F at 77°F) (analog models only)
Temperature Sensor Accuracy, RTD: DIN Class B: ±0.3°C at 0°C (±0.54°F at 32°F) (analog models only)
Resolution: Relative humidity: 0.1%; temperature: 0.1°F/°C; absolute humidity: 0.1 g/m3
Humidity Analog Output 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Active Temperature Analog Output 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Passive Temperature Sensors Types II and III: Solid state band gap; Curves A, B, and F: Thermistor; Curves D and E: Platinum RTD DIN BS, BACnet MS/TP protocol or Modbus® RTU (communicating models only)
Network Communication BACnet MS/TP protocol or Modbus® RTU (communicating models only)
Supported BAUD Rates 9600, 19200, 38400, 57600, 76800, 115200 (communicating models only)
Termination Load 120 Ω (communicating models only)
Operating Temperature Range -40 to 60°C (-40 to 140°F); With LCD: -20 to 60°C (-4 to 140°F)
Power Requirements Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac
Wiring Connection Removable terminal block
Electrical Entry 1/2” NPS thread. Cable gland included
Enclosure Material UL 94 V-0
Enclosure Rating IP66
Optional Display Two (2) lines of alphanumeric characters with eight (8) characters per line
Weight: Duct 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1724.7 g (2.75 lb)
Storage Temperature -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F)
Additional calculations Absolute humidity: (0 to 50) g/m3 or (0 to 3000) lb/mmcf; dew point -75 °C to 60 °C (-102 °F to 140 °F); enthalpy (40 to 411) kj/kg (or -1 to 177 Btu/lb)
Compliance BTL, CE, UL 2043*, UL-60335-2-40**
Click here for complete specifications on the Dwyer RHPX-2SDA0-00-LCD

What's included with the Dwyer RHPX-2SDA0-00-LCD

  • Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% accuracy

Ask a question about Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% RH accuracy

Customer Reviews for the Dwyer RHPX-2SDA0-00-LCD

Dwyer RHPX-2SDA0-00-LCD Offers

Equipped with capacitance polymer humidity sensors, the RHPX-2SDA0-00-LCD offers ±2% accuracy. Features a duct mount with plenum plastic probe and hydrophobic filter sensor configuration, selectable analog output, and two-line alphanumeric LCD display. With high accuracy, long-term stability, and reliable operation in various enclosure styles, the RHPX is ideal for building energy management systems, commercial HVAC systems, clean rooms, museums, and data centers. It can also be configured to provide absolute or relative humidity, dew point, or enthalpy.

Features

  • Reduced installation costs with multiple on-board sensors
  • Minimal maintenance with UV rated outdoor enclosures
  • UL 2043 compliant allows installation into the plenum space
  • Intrinsically safe hazardous area versions.
  • Easy installation with removable terminal block, attached lid, and cable management

Applications

  • Air economizers
  • Outdoor humidity and temperature reference
  • Pool room humidity monitoring
  • Building energy management systems
  • Commercial HVAC systems
  • Clean rooms
  • Museums
  • Data centers

Dwyer RHPX-2SDA0-00-LCD Specifications

Humidity Measurement Range 0% to 100% humidity.
Temperature Measurement Range -40 to 60°C (-40 to 140°F)
Humidity Sensor Accuracy ±2 % at 10 % - 90 % RH and 25 °C (77°F)
Temperature Sensor Accuracy, Solid State Band Gap: ±0.9°F (±0.5°C at 25°C)
Temperature Sensor Accuracy, Thermistor: ±0.2°C at 25°C (±0.36°F at 77°F) (analog models only)
Temperature Sensor Accuracy, RTD: DIN Class B: ±0.3°C at 0°C (±0.54°F at 32°F) (analog models only)
Resolution: Relative humidity: 0.1%; temperature: 0.1°F/°C; absolute humidity: 0.1 g/m3
Humidity Analog Output 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Active Temperature Analog Output 4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Passive Temperature Sensors Types II and III: Solid state band gap; Curves A, B, and F: Thermistor; Curves D and E: Platinum RTD DIN BS, BACnet MS/TP protocol or Modbus® RTU (communicating models only)
Network Communication BACnet MS/TP protocol or Modbus® RTU (communicating models only)
Supported BAUD Rates 9600, 19200, 38400, 57600, 76800, 115200 (communicating models only)
Termination Load 120 Ω (communicating models only)
Operating Temperature Range -40 to 60°C (-40 to 140°F); With LCD: -20 to 60°C (-4 to 140°F)
Power Requirements Communications model: 14 to 35 Vdc or 10 to 32 Vac; Analog model: 4-20 mA: 10 to 35 Vdc; Vout: 15 to 35 Vdc or 15 to 29 Vac
Wiring Connection Removable terminal block
Electrical Entry 1/2” NPS thread. Cable gland included
Enclosure Material UL 94 V-0
Enclosure Rating IP66
Optional Display Two (2) lines of alphanumeric characters with eight (8) characters per line
Weight: Duct 198.4 g (0.44 lb); wall mount: 170 g (0.38 lb); large housing: 340.2 g (0.75 lb); large housing with radiation shield: 1724.7 g (2.75 lb)
Storage Temperature -40°C to 70°C (-40°F to 158°F); With LCD: -30°C to 70°C (-22°F to 158°F)
Additional calculations Absolute humidity: (0 to 50) g/m3 or (0 to 3000) lb/mmcf; dew point -75 °C to 60 °C (-102 °F to 140 °F); enthalpy (40 to 411) kj/kg (or -1 to 177 Btu/lb)
Compliance BTL, CE, UL 2043*, UL-60335-2-40**
Click here for complete specifications on the Dwyer RHPX-2SDA0-00-LCD

What's included with the Dwyer RHPX-2SDA0-00-LCD

  • Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% accuracy

Ask a question about Dwyer RHPX-2SDA0-00-LCD Humidity/Temperature Transmitter, 2% RH accuracy

Customer Reviews for the Dwyer RHPX-2SDA0-00-LCD

More Dwyer Products

Calibration Lab