Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Model: IS626-12-GH-P1-E1-S1

Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Model: IS626-12-GH-P1-E1-S1

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Sale Price $511.94 USD
Regular Price $559.50 USD
Availability 3 to 4 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Dwyer IS626-12-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 200 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

What's included with the Dwyer IS626-12-GH-P1-E1-S1

  • Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Click on a category to view a selection of compatible accessories with the Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig).

Dwyer MTL5541 Galvanic Isolator, Is, Is626, Sbltx & Pbltx Ser MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Dwyer MTL7706 Zener Barrier, Is, For Is626, Sbltx & Pbltx Ser MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Ask a question about Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Customer Reviews for the Dwyer IS626-12-GH-P1-E1-S1

Dwyer IS626-12-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 200 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

What's included with the Dwyer IS626-12-GH-P1-E1-S1

  • Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Click on a category to view a selection of compatible accessories with the Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig).

Dwyer MTL5541 Galvanic Isolator, Is, Is626, Sbltx & Pbltx Ser MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Dwyer MTL7706 Zener Barrier, Is, For Is626, Sbltx & Pbltx Ser MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Ask a question about Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Customer Reviews for the Dwyer IS626-12-GH-P1-E1-S1

More Dwyer Products

Calibration Lab